CoChat

The cytokeratin filament-aggregating protein filaggrin is the target of the so-called "antikeratin antibodies," autoantibodies specific for rheumatoid arthritis.

Open access
Simon, M, Girbal, E, Sebbag, M, Gomès-Daudrix, V, Vincent, C, Salama, G, Serre, G · 1993 · Journal of Clinical Investigation
Cited by 262

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

In rheumatoid arthritis (RA), the high diagnostic value of serum antibodies to the stratum corneum of rat esophagus epithelium has been widely reported.These so-called "antikeratin antibodies," detected by indirect immunofluorescence, were found to be autoantibodies since they also labeled human epidermis.Despite their name, the actual target of these autoanti- bodies was not known.In this study, a 40-kD protein (designated as 40K), extracted from human epidermis and specifically immunodetected by 75% of RA sera, was purified and identified as a neutral/acidic isoform of basic filaggrin, a cytokeratin filament-aggregating protein, by peptide mapping stud- ies and by the following evidences: (a) mAbs specific for filag- grin reacted with the 40K protein; (b) the autoantibodies, affin- ity-purified from RA sera on the 40K protein, immunodetected purified filaggrin; (c) the reactivity of RA sera to the 40K protein was abolished after immunoadsorption with purified filag- grin; (d) the 40K protein and filaggrin had similar amino acid compositions.Furthermore, autoantibodies against the 40K protein and the so-called "antikeratin antibodies" were shown, by immunoadsorption experiments, to be largely the same.The identification of filaggrin as a RA-specific autoantigen could contribute to the understanding of the pathogenesis of this dis- ease and, ultimately, to the development of methods for preventing the autoimmune response.(J.Clin.Invest.1993.92:1387-1393.)Key words: autoimmunity * autoantigen * diag- nosis * intermediate filament-associated protein * epidermis was submitted to SDS-PAGE and electrotransferred to immobilon- PVDF membranes (Millipore Corp., Bedford, MA).The 40K protein Antifilaggrin Autoantibodies Specificfor Rheumatoid Arthritis 1387

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci116713

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 262

Metadata

Authors
Simon, M., Girbal, E., Sebbag, M., Gomès-Daudrix, V, Vincent, C., Salama, G., & Serre, G.
Venue
Journal of Clinical Investigation
Published
1993-09-01
Volume
92
Issue
3
Pages
1387-1393
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2006167010
Cited by
262
References
17
FWCI
6.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.