Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 426

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Gastric emptying and release of incretin hormones after glucose ingestion in humans.

Open access
Schirra, J, Katschinski, M, Weidmann, C, Schäfer, T, Wank, U, Arnold, R, Göke, B·1996·Journal of Clinical Investigation

Abstract

This study investigated in eight healthy male volunteers (a) the gastric emptying pattern of 50 and 100 grams of glucose; (b) its relation to the phase of interdigestive motility (phase I or II) existing when glucose was ingested; and (c) the interplay between gastric emptying or duodenal perfusion of glucose (1.1 and 2.2 kcal/min; identical total glucose loads as orally given) and release of glucose-dependent insulinotropic peptide (GIP), glucagon-like peptide-1(7-36)amide (GLP-1), C-peptide, insulin, and plasma glucose. The phase of interdigestive motility existing at the time of glucose ingestion did not affect gastric emptying or any metabolic parameter. Gastric emptying of glucose displayed a power exponential pattern with a short initial lag period. Duodenal delivery of glucose was not constant but exponentially declined over time. Increasing the glucose load reduced the rate of gastric emptying by 27.5% (P < 0.05) but increased the fractional duodenal delivery of glucose. Both glucose loads induced a fed motor pattern which was terminated by an antral phase III when approximately 95% of the meal had emptied. Plasma GLP-1 rose from basal levels of approximately 1 pmol/liter of peaks of 3.2 +/- 0.6 pmol/liter with 50 grams of glucose and of 7.2 +/- 1.6 pmol/liter with 100 grams of glucose. These peaks occurred 20 min after glucose intake irrespective of the load. A duodenal delivery of glucose exceeding 1.4 kcal/min was required to maintain GLP-1 release in contrast to ongoing GIP release with negligibly low emptying of glucose. Oral administration of glucose yielded higher GLP-1 and insulin releases but an equal GIP release compared with the isocaloric duodenal perfusion. We conclude that (a) gastric emptying of glucose displays a power exponential pattern with duodenal delivery exponentially declining over time and (b) a threshold rate of gastric emptying of glucose must be exceeded to release GLP-1, whereas GIP release is not controlled by gastric emptying.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci118411

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 426

Metadata

Authors
Schirra, J., Katschinski, M., Weidmann, C., Schäfer, T., Wank, U., Arnold, R., & Göke, B.
Venue
Journal of Clinical Investigation
Published
1996-01-01
Volume
97
Issue
1
Pages
92-103
ISSN
0021-9738 (ISSN-L)
OpenAlex
W1972534040
Cited by
426
References
7
FWCI
13.71
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gastric emptying and release of incretin hormones after glucose ingestion in humans. https://app.cochat.ai/papers/10.1172/jci118411
The paper
Schirra, J., Katschinski, M., Weidmann, C., Schäfer, T., Wank, U., Arnold, R., & Göke, B. (1996). Gastric emptying and release of incretin hormones after glucose ingestion in humans. Journal of Clinical Investigation. https://doi.org/10.1172/jci118411

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.