Validations of a Portable Home Sleep Study with Twelve-Lead Polysomnography: Comparisons and Insights into a Variable Gold Standard
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objectives: Accurate and timely diagnosis for patients with obstructive sleep apnea (OSA) is imperative. Unfortunately, growing interest in this diagnosis has resulted in increased requests and waiting times for polysomnography (PSG), as well as a potential delay in diagnosis and treatment. This study evaluated the accuracy and viability of utilizing SNAP (SNAP Laboratories, LLC, Wheeling, Illinois), a portable home sleep test, as an alternative to traditional PSG in diagnosing OSA. Methods: This prospective clinical trial included 59 patients evaluated at our institution's sleep laboratory. Concurrent PSG and SNAP testing was performed for 1 night on each patient. Independent, blinded readers at our institution and at an outside-accredited institution read the PSG data, and 2 independent, blinded readers interpreted the SNAP data at SNAP laboratories. The apnea-hypopnea index (AHI) was used to compare the 2 testing modalities. The correlation coefficient, receiver operating characteristic curve analysis, and the Bland-Altman curves, as well as sensitivity, specificity, inter-reader variability, positive predictive value, and negative predictive value, were used to compare SNAP and PSG. Results: There is a definitive, statistically sound correlation between the AHIs determined from both PSG and SNAP. This relationship holds true for all measures of comparison, while displaying a concerning, weaker correlation between the different PSG interpretations. Conclusions: There is a convincing correlation between the study-determined AHIs of both PSG and SNAP. This finding supports SNAP as a suitable alternative to PSG in identifying OSA, while accentuating the inherent variation present in a PSG-derived AHI. This test expands the diagnostic and therapeutic prowess of the practicing otolaryngologist by offering an alternative OSA testing modality that is associated with not only less expense, decreased waiting time, and increased convenience, but also statistically proven accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Instrument to Measure Functional Status Outcomes for Disorders of Excessive Sleepiness
(1997) · Sleep · doi:10.1093/sleep/20.10.835 · Cited by 881
Effects of Varying Approaches for Identifying Respiratory Disturbances on Sleep Apnea Assessment
REDLINE, S., KAPUR, V. K., SANDERS, M. H., QUAN, S. F., GOTTLIEB, D. J., RAPOPORT, D. M., BONEKAT, W. H., SMITH, P. L., KILEY, J. P., & IBER, C. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.2.9904031 · Cited by 225
Cited by
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
Low efficacy of atrial fibrillation ablation in severe obstructive sleep apnoea patients
Matiello, M., Nadal, M., Tamborero, D., Berruezo, A., Montserrat, J., Embid, C., Rios, J., Villacastin, J., Brugada, J., & Mont, L. (2010) · Europace · doi:10.1093/europace/euq128 · Cited by 156
“The respiratory sleep apnoea was not performed in patients with low BQ scores; they were included in the low OSA risk group, along with patients having an AHI , 10.(14)”
MethodStimulant medications and sleep for youth with ADHD: a meta-analysis
Kidwell, K. M., Van Dyk, T. R., Lundahl, A., & Nelson, T. D. (2015) · Pediatrics · doi:10.1542/peds.2015-1708 · Cited by 133
Day-to-day relations between stress and sleep and the mediating role of perseverative cognition
Van Laethem, M., Beckers, D. G. J., van Hooff, M. L. M., Dijksterhuis, A., & Geurts, S. A. E. (2016) · Sleep Medicine · doi:10.1016/j.sleep.2016.06.020 · Cited by 38
Metadata
- Authors
- Michaelson, P. G., Allan, P., Chaney, J., & Mair, E. A.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 2006-11
- Volume
- 115
- Issue
- 11
- Pages
- 802-809
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2054427504
- Cited by
- 34
- References
- 2
- FWCI
- 0.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validations of a Portable Home Sleep Study with Twelve-Lead Polysomnography: Comparisons and Insights into a Variable Gold Standard. https://app.cochat.ai/papers/10.1177/000348940611501102
- The paper
- Michaelson, P. G., Allan, P., Chaney, J., & Mair, E. A. (2006). Validations of a Portable Home Sleep Study with Twelve-Lead Polysomnography: Comparisons and Insights into a Variable Gold Standard. Annals of Otology, Rhinology & Laryngology. https://doi.org/10.1177/000348940611501102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.