Auditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Although single-channel electrode arrays implanted in the scala tympani of deaf patients are useful as an aid to lip reading and for distinguishing some environmental sounds, they do not transmit intelligible speech. However, multichannel electrode arrays, which take advantage of the cochlea's tonotopic organization, may be capable of generating the complex patterns of neural activity necessary for speech discrimination. In this study, multichannel electrodes were implanted in the cochleas of four volunteers, with access to the connecting wires made through the skin via a percutaneous connector. The major portion of the data presented is from two of these subjects: one has been bilaterally deaf since birth and the other has been unilaterally deaf for 15 years. Preliminary results of experiments with two more recently implanted subjects are described as well as experiments with a fifth volunteer who was implanted with five electrodes by House in 1969. Data on pitch and loudness discrimination as well as the effects of stimulation parameters on threshold, impedance, and electrode interaction are presented. Place pitch and periodicity pitch were observed in all five volunteers. The results of pitch-matching experiments with the unilaterally deaf volunteer were consistent with tonotopic maps of the cochlea, and experiments indicated that a pitch continuum may be achieved by combining place and periodicity pitch modulation. Preliminary experiments in tune recognition with one subject demonstrate his ability to recognize simple melodies based on periodicity pitch cues. These results, coupled with the finding that subjective sensations remain stable over the long-term, support the feasibility of providing artificial hearing with a multichannel cochlear stimulation system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Contributions to Sensory Physiology
Davson, H. (1965) · BMJ · doi:10.1136/bmj.2.5461.583-a · Cited by 714
Electrical Stimulation of the Auditory Nerve in Man
SIMMONS, F. B. (1966) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1966.00760030004003 · Cited by 613
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Self-citationDobelle, W. H., Mladejovsky, M. G., & Girvin, J. P. (1974) · Science · doi:10.1126/science.183.4123.440 · Cited by 440
Self-citationLong Term Results of Electrode Implantation and Electronic Stimulation of the Cochlea in Man
House, W. F., & Urban, J. (1973) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348947308200408 · Cited by 354
Physiological Considerations in Artificial Stimulation of the Inner Ear
Kiang, N. Y. S., & Moxon, E. C. (1972) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348947208100513 · Cited by 342
(1800) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1800.0018 · Cited by 342
Tonndorf, J. (1977) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894770860s601 · Cited by 319
“Braille” reading by a blind volunteer by visual cortex stimulation
DOBELLE, W. H., MLADEJOVSKY, M. G., EVANS, J. R., ROBERTS, T. S., & GIRVIN, J. P. (1976) · Nature · doi:10.1038/259111a0 · Cited by 253
Self-citationBrightness and loudness as functions of stimulus duration
Stevens, J. C., & Hall, J. W. (1966) · Perception & Psychophysics · doi:10.3758/bf03207399 · Cited by 220
Scanning Electron Microscopic Study of the Organ of Corti in Normal and Sound-Damaged Guinea Pigs
Soudijn, E. R. (1976) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894760850s401 · Cited by 148
Research Plan for Evaluating Subjects Presently Fitted with Implanted Auditory Prostheses
Bilger, R. C., Black, F. O., & Hopkinson, N. T. (1977) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894770860s303 · Cited by 142
Brain tissue reaction to some chronically implanted metals
Dymond, A. M., Kaechele, L. E., Jurist, J. M., & Crandall, P. H. (1970) · Journal of Neurosurgery · doi:10.3171/jns.1970.33.5.0574 · Cited by 140
Electrical Stimulation of the Human Cochlea: A Preliminary Report
Michelson, R. P. (1971) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1971.00770060455016 · Cited by 125
Recovery of the Auditory Threshold after Strong Acoustic Stimulation
Hirsh, I. J., & Ward, W. D. (1952) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906867 · Cited by 114
House, W. F. (1976) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894760850s303 · Cited by 100
Elimination of Biases in Loudness Judgments for Tones
Warren, R. M. (1970) · The Journal of the Acoustical Society of America · doi:10.1121/1.1912298 · Cited by 97
A Prosthesis for the Deaf Based on Cortical Stimulation
Dobelle, W. H., Stensaas, S. S., Mladejovsky, M. G., & Smith, J. B. (1973) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348947308200404 · Cited by 83
Self-citationElectrical Stimulation of Acoustical Nerve and Inferior Colliculus: Results in Man
Simmons, F. B., Mongeon, C. J., LEWIS, W. R., & Huntington, D. A. (1964) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1964.00750030572003 · Cited by 77
Hughes, J. R. (1954) · The Journal of the Acoustical Society of America · doi:10.1121/1.1907450 · Cited by 39
Symposium on cochlear implants. II. feasibility of multichannel scala tympani stimulation
Merzenich, M. M., Schindler, D. N., & White, M. W. (1974) · The Laryngoscope · doi:10.1002/lary.5540841105 · Cited by 34
A Computer-Based Brain Stimulation System to Investigate Sensory Prostheses for the Blind and Deaf
Mladejovsky, M. G., Eddington, D. K., Evans, J. R., & Dobelle, W. H. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324587 · Cited by 28
Self-citationFabrication of large arrays of cortical electrodes for use in man
Klomp, G. F., Womack, M. V. B., & Dobelle, W. H. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110304 · Cited by 15
Self-citationPostexposure Responsiveness in the Auditory System. II. Sensitization and Desensitization
Noffsinger, P. D., & Olsen, W. O. (1970) · The Journal of the Acoustical Society of America · doi:10.1121/1.1911928 · Cited by 13
Moore, T. J. (1968) · The Journal of the Acoustical Society of America · doi:10.1121/1.1911274 · Cited by 11
Watson, W. (1752) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1751.0032 · Cited by 10
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“The Utah six-electrode, four-channel system had a percutaneous plug and contained no internal circuits [22].”
BackgroundMethodResultInfluentialMusic Perception with Cochlear Implants: A Review
McDermott, H. J. (2004) · Trends in Amplification · doi:10.1177/108471380400800203 · Cited by 549
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4005.1201 · Cited by 380
Music Perception with Temporal Cues in Acoustic and Electric Hearing
Kong, Y.-Y., Cruz, R., Jones, J. A., & Zeng, F.-G. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000120365.97792.2f · Cited by 377
Metadata
- Authors
- Eddington, D. K., Dobelle, W. H., Mladejovsky, M. G., Brackmann, D. E., & Parkin, J. L.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 1978-11
- Volume
- 87
- Issue
- 6_suppl
- Pages
- 5-39
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2402811972
- Cited by
- 334
- References
- 26
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.