Auditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Although single-channel electrode arrays implanted in the scala tympani of deaf patients are useful as an aid to lip reading and for distinguishing some environmental sounds, they do not transmit intelligible speech. However, multichannel electrode arrays, which take advantage of the cochlea's tonotopic organization, may be capable of generating the complex patterns of neural activity necessary for speech discrimination. In this study, multichannel electrodes were implanted in the cochleas of four volunteers, with access to the connecting wires made through the skin via a percutaneous connector. The major portion of the data presented is from two of these subjects: one has been bilaterally deaf since birth and the other has been unilaterally deaf for 15 years. Preliminary results of experiments with two more recently implanted subjects are described as well as experiments with a fifth volunteer who was implanted with five electrodes by House in 1969. Data on pitch and loudness discrimination as well as the effects of stimulation parameters on threshold, impedance, and electrode interaction are presented. Place pitch and periodicity pitch were observed in all five volunteers. The results of pitch-matching experiments with the unilaterally deaf volunteer were consistent with tonotopic maps of the cochlea, and experiments indicated that a pitch continuum may be achieved by combining place and periodicity pitch modulation. Preliminary experiments in tune recognition with one subject demonstrate his ability to recognize simple melodies based on periodicity pitch cues. These results, coupled with the finding that subjective sensations remain stable over the long-term, support the feasibility of providing artificial hearing with a multichannel cochlear stimulation system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Contributions to Sensory Physiology
Davson, H. (1965) · BMJ · doi:10.1136/bmj.2.5461.583-a · Cited by 714
Electrical Stimulation of the Auditory Nerve in Man
SIMMONS, F. B. (1966) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1966.00760030004003 · Cited by 613
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Self-citationDobelle, W. H., Mladejovsky, M. G., & Girvin, J. P. (1974) · Science · doi:10.1126/science.183.4123.440 · Cited by 440
Self-citationLong Term Results of Electrode Implantation and Electronic Stimulation of the Cochlea in Man
House, W. F., & Urban, J. (1973) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348947308200408 · Cited by 354
Physiological Considerations in Artificial Stimulation of the Inner Ear
Kiang, N. Y. S., & Moxon, E. C. (1972) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348947208100513 · Cited by 342
(1800) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1800.0018 · Cited by 342
Tonndorf, J. (1977) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894770860s601 · Cited by 319
“Braille” reading by a blind volunteer by visual cortex stimulation
DOBELLE, W. H., MLADEJOVSKY, M. G., EVANS, J. R., ROBERTS, T. S., & GIRVIN, J. P. (1976) · Nature · doi:10.1038/259111a0 · Cited by 253
Self-citationBrightness and loudness as functions of stimulus duration
Stevens, J. C., & Hall, J. W. (1966) · Perception & Psychophysics · doi:10.3758/bf03207399 · Cited by 220
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“The Utah six-electrode, four-channel system had a percutaneous plug and contained no internal circuits [22].”
BackgroundMethodResultInfluentialMusic Perception with Cochlear Implants: A Review
McDermott, H. J. (2004) · Trends in Amplification · doi:10.1177/108471380400800203 · Cited by 549
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4005.1201 · Cited by 380
Music Perception with Temporal Cues in Acoustic and Electric Hearing
Kong, Y.-Y., Cruz, R., Jones, J. A., & Zeng, F.-G. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000120365.97792.2f · Cited by 377
Multichannel electrical stimulation of the auditory nerve in man. I. Basic psychophysics
Shannon, R. V. (1983) · Hearing Research · doi:10.1016/0378-5955(83)90077-1 · Cited by 364
Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
Shepherd, R. K., Hatsushika, S., & Clark, G. M. (1993) · Hearing Research · doi:10.1016/0378-5955(93)90265-3 · Cited by 360
Temporal pitch in electric hearing
Zeng, F.-G. (2002) · Hearing Research · doi:10.1016/s0378-5955(02)00644-5 · Cited by 314
Vandali, A. E., Whitford, L. A., Plant, K. L., & Clark, A. G. M. (2000) · Ear and Hearing · doi:10.1097/00003446-200012000-00008 · Cited by 308
Discharge patterns of cat primary auditory fibers with electrical stimulation of the cochlea
Hartmann, R., Topp, G., & Klinke, R. (1984) · Hearing Research · doi:10.1016/0378-5955(84)90094-7 · Cited by 298
Shepherd, R. K., & Javel, E. (1997) · Hearing Research · doi:10.1016/s0378-5955(97)00046-4 · Cited by 292
Single fiber mapping of spatial excitation patterns in the electrically stimulated auditory nerve
van den Honert, C., & Stypulkowski, P. H. (1987) · Hearing Research · doi:10.1016/0378-5955(87)90167-5 · Cited by 209
Multichannel electrical stimulation of the auditory nerve in man. II. Channel interaction
Shannon, R. V. (1983) · Hearing Research · doi:10.1016/0378-5955(83)90115-6 · Cited by 203
Deafness-Induced Changes in the Auditory Pathway: Implications for Cochlear Implants
Shepherd, R. K., & Hardie, N. A. (2001) · Audiology and Neurotology · doi:10.1159/000046843 · Cited by 189
“…shown a consistently poor quality of hearing sensations perceived by these early deafened adult implant recipients, including electrode pitch percepts that show no consistent variation with tonotopic organization, and poor temporal processing skills [Eddington et al., 1978; Busby et al., 1992].”
Speech dynamic range and its effect on cochlear implant performance
Zeng, F.-G., Grant, G., Niparko, J., Galvin, J., Shannon, R., Opie, J., & Segel, P. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1423926 · Cited by 171
The effect of parametric variations of cochlear implant processors on speech understanding
Loizou, P. C., Poroy, O., & Dorman, M. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.429612 · Cited by 164
Clark, G. M. (2015) · Hearing Research · doi:10.1016/j.heares.2014.08.002 · Cited by 161
Metadata
- Authors
- Eddington, D. K., Dobelle, W. H., Mladejovsky, M. G., Brackmann, D. E., & Parkin, J. L.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 1978-11
- Volume
- 87
- Issue
- 6_suppl
- Pages
- 5-39
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2402811972
- Cited by
- 334
- References
- 26
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.