What is the most suitable blood collection tube for glucose estimation?
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Objectives: Glucose is one of the most frequently measured analytes in laboratories. Most recent studies on glucose stabilities confirm that the sodium fluoride/potassium oxalate (NaF/KOx) tube is far from the gold standard. Citrate tubes have been suggested as the preferred tube type by many institutions. Greiner has introduced a glucose-specific tube (Glucomedics) containing NaF/KOx, citrate, and EDTA to minimise glycolysis. The aim was to determine which tube would be the most suitable for accurate glucose estimation in a routine laboratory setting. Design and methods: The study process involved three experiments: (a) participant comparison using lithium heparin plasma as the comparative sample; (b) stability study (0, 1, 2 and 4 h); and (c) minimal fill volume for the citrate and the Glucomedics tubes. Results: The patient comparison study of lithium heparin plasma showed that EDTA, NaF/KOx, and both citrate and Glucomedics if corrected for dilutional factors produced acceptable results. The stability study up to 4 h showed that the Glucomedics tube was most effective in preventing clinically significant change in glucose concentration at a room temperature. Both citrate and Glucomedics need to be filled within 0.5 mL of the recommended fill volume for acceptable results. Conclusion: The Glucomedics tube is the most suitable for minimising glycolysis. Further improvements to it (use of correct dilutional factor and the addition of gel separator) would make this tube the benchmark for the most accurate estimation, best diagnosis and patient care decisions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360 · cited 2×
“This fact has not been examined by the different publications nor has it been taken into consideration when studying its suitability to date, even though the tube has been implemented as the tube of choice by countries and individual health institutions.(6,7) Serum data showed that the recommended clotting time of 30m…”
BackgroundMethodAcidification of blood is superior to sodium fluoride alone as an inhibitor of glycolysis
Gambino, R., Piscitelli, J., Ackattupathil, T. A., Theriault, J. L., Andrin, R. D., Sanfilippo, M. L., & Etienne, M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.121707 · Cited by 160 · cited 8×
“Gambino et al. found that glucose decreased in NaF/KOx tubes (BD tubes) by 4.5% at 2 h, whereas our data (Greiner tubes) showed a more significant decrease, 7% which could be influenced by storage and centrifugation temperature.”
BackgroundMethodInfluentialStabilization of glucose in blood samples: why it matters
Bruns, D. E., & Knowler, W. C. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.126037 · Cited by 125 · cited 3×
“be ineffective in inhibiting glycolysis as is blood without it,(1) specifically in the first 3–4 h.(2) Studies have shown that both serum and lithium heparin plasma have higher glucose concentrations than NaF/KOx plasma.”
BackgroundMethodInfluentialA new method of inhibiting glycolysis in blood samples
Uchida, K., Matuse, R., Toyoda, E., Okuda, S., & Tomita, S. (1988) · Clinica Chimica Acta · doi:10.1016/0009-8981(88)90125-8 · Cited by 53
Cited by
Validation of biomarkers of food intake—critical assessment of candidate biomarkers
Dragsted, L. O., Gao, Q., Scalbert, A., Vergères, G., Kolehmainen, M., Manach, C., Brennan, L., Afman, L. A., Wishart, D. S., Andres Lacueva, C., et al. (2018) · Genes & Nutrition · doi:10.1186/s12263-018-0603-9 · Cited by 230
Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results
Pasqualetti, S., Braga, F., & Panteghini, M. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.03.009 · Cited by 41
“The use of citrate in liquid form (Vacuette® Glucomedics, Greiner Bio-One) also implied the obtainment of PG results significantly higher in comparison to those obtained using fluoride only [25-28].”
BackgroundResultBlood Glucose Determination: Effect of Tube Additives
(2018) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2017.12.003 · Cited by 28
Carey, R., Lunt, H., Heenan, H. F., Frampton, C. M. A., & Florkowski, C. M. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.05.017 · Cited by 26
Metadata
- Authors
- Dimeski, G., Yow, K. S., & Brown, N. N.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2014-07-07
- Volume
- 52
- Issue
- 2
- Pages
- 270-275
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W2331733105
- Cited by
- 47
- References
- 4
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: What is the most suitable blood collection tube for glucose estimation? https://app.cochat.ai/papers/10.1177/0004563214544708
- The paper
- Dimeski, G., Yow, K. S., & Brown, N. N. (2015). What is the most suitable blood collection tube for glucose estimation? Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1177/0004563214544708
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.