Identifying mislabelled samples: Machine learning models exceed human performance
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background: It is difficult for clinical laboratories to identify samples that are labelled with the details of an incorrect patient. Many laboratories screen for these errors with delta checks, with final decision-making based on manual review of results by laboratory staff. Machine learning models have been shown to outperform delta checks for identifying these errors. However, a comparison of machine learning models to human-level performance has not yet been made. Methods: Deidentified data for current and previous (within seven days) electrolytes, urea and creatinine results was used in the computer simulation of mislabelled samples. Eight different machine learning models were developed on 127,256 sets of results using different algorithms: artificial neural network, extreme gradient boosting, support vector machine, random forest, logistic regression, k-nearest neighbours and two decision trees (one complex and one simple). A separate test data-set ( n = 14,140) was used to evaluate the performance of these models as well as laboratory staff volunteers, who manually reviewed a random subset of this data ( n = 500). Results: The best performing machine learning model was the artificial neural network (92.1% accuracy), with the simple decision tree demonstrating the poorest accuracy (86.5%). The accuracy of laboratory staff for identifying mislabelled samples was 77.8%. Conclusions: The results of this preliminary investigation suggest that even relatively simple machine learning models can exceed human performance for identifying mislabelled samples. Machine learning techniques should be considered for implementation in clinical laboratories to assist with error identification.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In their study, Farrell et al. conducted research to detect mislabeled samples [24].”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as [24]
In the citing paper
“Notably, the ANN model yielded impressive results, achieving an accuracy of 92.1 % and an area under the curve (AUC) of 0.977.”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as [24]
In the citing paper
“These findings unequivocally demonstrate the superiority of ML algorithms over human capabilities in accurately identifying incorrectly labeled samples [24].”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as [24]
Citations
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2025) · doi:10.32614/r.manuals · Cited by 352,181
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850 · cited 1×
“Finally, the simulated error rate was significantly higher than sample mislabelling in practice.(6) This was necessary to assess human-level performance, as only 500 sample pairs were reviewed by volunteers.”
BackgroundDelta Checks in the clinical laboratory
Randell, E. W., & Yenice, S. (2019) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1540536 · Cited by 65 · cited 1×
“Current laboratory practice is to use delta checks to screen for these errors and have results failing delta checks manually reviewed by laboratory staff.(1) Preliminary investigations have demonstrated that machine learning (ML) models are superior to delta checks in identifying mislabelled samples.”
BackgroundUsing Machine Learning-Based Multianalyte Delta Checks to Detect Wrong Blood in Tube Errors
Rosenbaum, M. W., & Baron, J. M. (2018) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqy085 · Cited by 58 · cited 1×
“Preliminary investigations have demonstrated that machine learning (ML) models are superior to delta checks in identifying mislabelled samples.(2,3) The relative performance of different ML algorithms has not been established, however.”
BackgroundDevelopment and characterization of neural network-based multianalyte delta checks
Jackson, C. R., & Cervinski, M. A. (2020) · Journal of Laboratory and Precision Medicine · doi:10.21037/jlpm.2020.02.03 · Cited by 9 · cited 1×
“Preliminary investigations have demonstrated that machine learning (ML) models are superior to delta checks in identifying mislabelled samples.(2,3) The relative performance of different ML algorithms has not been established, however.”
Background
Cited by
Applications of machine learning in routine laboratory medicine: Current state and future directions
Rabbani, N., Kim, G. Y. E., Suarez, C. J., & Chen, J. H. (2022) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2022.02.011 · Cited by 118
Clinlabomics: leveraging clinical laboratory data by data mining strategies
Wen, X., Leng, P., Wang, J., Yang, G., Zu, R., Jia, X., Zhang, K., Mengesha, B. A., Huang, J. H., Wang, D., et al. (2022) · BMC Bioinformatics · doi:10.1186/s12859-022-04926-1 · Cited by 81
Integration of artificial intelligence in clinical laboratory medicine: Advancements and challenges
Xie, H., Jia, Y. H., & Liu, S. (2024) · Interdisciplinary medicine · doi:10.1002/inmd.20230056 · Cited by 85
Machine learning-based clinical decision support using laboratory data
Çubukçu, H. C., Topcu, D. İ., & Yenice, S. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1037 · Cited by 66
“In their study, Farrell et al. conducted research to detect mislabeled samples [24].”
BackgroundArtificial intelligence in the clinical laboratory
Hou, H., Zhang, R., & Li, J. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.119724 · Cited by 65
Sharma, R., Diksha, D., Bhute, A. R., & Bastia, B. K. (2022) · Forensic Science International · doi:10.1016/j.forsciint.2022.111473 · Cited by 58
Ephraim, R. K. D., Kotam, G. P., Duah, E., Ghartey, F. N., Mathebula, E. M., & Mashamba-Thompson, T. P. (2024) · Smart Health · doi:10.1016/j.smhl.2024.100505 · Cited by 58
Artificial intelligence and infectious disease diagnostics: state of the art and future perspectives
Miglietta, L., Rawson, T. M., Galiwango, R. M., Tasker, A. J., Ming, D. K. Y., Akogo, D., Ferreyra, C., Aboagye, E. O., Gordon, N. C., García‐Vidal, C., et al. (2025) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(25)00354-8 · Cited by 54
Lorde, N., Mahapatra, S., & Kalaria, T. (2024) · Diagnostics · doi:10.3390/diagnostics14161808 · Cited by 38
“Farrell tested eight different ML models against human performance for the detection of WBIT [40].”
MethodThe preanalytical phase – from an instrument-centred to a patient-centred laboratory medicine
Cadamuro, J., & Šimundić, A.-M. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1036 · Cited by 37
“Therefore, the obvious solution is the development of artificial intelligence (AI) systems, supporting test selection and interpretation as well as the identification of preanalytical biased samples [70 – 72].”
BackgroundCadamuro, J. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0620 · Cited by 33
Ain, Q. U., Nazir, R., Nawaz, A., Shahbaz, H., Dilshad, A., Mufti, I. U., & Iftikhar, M. (2024) · Journal of Clinical and Translational Pathology · doi:10.14218/jctp.2023.00061 · Cited by 27
“62 Furthermore, deep learning, particularly through CNNs, has proven highly effective in image-based assays, excelling in tasks like cell classification and anomaly detection.”
Farrell, C.-J. L., Makuni, C., Keenan, A., Maeder, E., Davies, G., & Giannoutsos, J. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad100 · Cited by 24
Self-citationTuning-Free Accountable Intervention for LLM Deployment – a Metacognitive Approach
Tan, Z. W., Peng, J., Wang, S., Hu, L., Chen, T., & Liu, H. (2025) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v39i24.34710 · Cited by 22
Artificial Intelligence Applications in Clinical Chemistry
Bunch, D. R., Durant, T. J. S., & Rudolf, J. W. (2022) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2022.09.005 · Cited by 21
Khokhar, M., Yadav, D., & Sharma, P. (2025) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-025-01315-2 · Cited by 18
Seok, H. S., Choi, Y., Yu, S., Shin, K., Kim, S., & Shin, H. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1185 · Cited by 15
Farrell, C.-J. L., & Giannoutsos, J. (2022) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13820 · Cited by 14
Self-citationDecision support or autonomous artificial intelligence? The case of wrong blood in tube errors
Farrell, C.-J. L. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0873 · Cited by 12
Self-citationLearning to Defer with Limited Expert Predictions
Hemmer, P., Thede, L., Vössing, M., Jakubik, J., & Kühl, N. (2023) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v37i5.25742 · Cited by 10
Transfer Assurance for Machine Learning in Autonomous Systems
Picardi, C., Hawkins, R., Paterson, C., & Habli, I. (2023) · White Rose Research Online (University of Leeds, The University of Sheffield, University of York) · Cited by 8
Loh, T. P., Tan, R. Z., Sethi, S. K., Lim, C. Y., & Markus, C. (2023) · Advances in clinical chemistry · doi:10.1016/bs.acc.2023.03.005 · Cited by 7
Graham, B. V., Master, S. R., Obstfeld, A. E., & Wilson, R. B. (2025) · Clinical Chemistry · doi:10.1093/clinchem/hvae210 · Cited by 7
Machine learning-based error detection in the clinical laboratory: a critical review
Lin, Y., Mensah, I. K., Doering, M. M., Shean, R. C., & Spies, N. C. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2512468 · Cited by 6
The role of AI in pre-analytical phase – use cases
Çubukçu, H. C. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1220 · Cited by 6
“…s investigation of mislabeled sample detection using 127,256 sets of consecutive electrolyte results achieved 92.1 % accuracy with an AUC of 0.977 [24], while a separate study by Farrell [25] utilizing 141,396 sets of electrolyte, urea, and creatinine results demonstrated that arti fi cial neural…”
InfluentialŞişman, A. R., Başok, B. İ., Karakoyun, İ., Çolak, A., Bilge, U., Demirci, F., & Başoğlu, N. (2024) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqad179 · Cited by 6
Farrell, C.-J. L. (2022) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632221128687 · Cited by 6
“The ANN used in this system had previously been demonstrated to out-perform laboratory staff and therefore increased trust would be expected to translate into improved user WBIT error detection.(5)”
MethodSelf-citationVasilev, Y. A., Nanova, O. G., Vladzymyrskyy, A. V., Goldberg, A. S., Blokhin, I. A., & Reshetnikov, R. V. (2025) · Digital Diagnostics · doi:10.17816/dd635349 · Cited by 5
Ibrahim, Z. A., & Al-Sambawee, M. A. J. (2026) · Discover Artificial Intelligence · doi:10.1007/s44163-026-00956-3 · Cited by 3
Künstliche Intelligenz im medizinischen Labor: KI – aktueller Stand und Zukunftsperspektiven
Mundorf, A. K., Ludwig, A., Früh, M., Höcker, R., Herrmann, F. P., Adler, J., & Kriegsmann, K. (2024) · Trillium Diagnostik · doi:10.47184/td.2024.01.08 · Cited by 3
Data analytics for error detection in clinical laboratories
Chan, C. W. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2555261 · Cited by 2
“…include the detection of pre-analytic errors, such as sample mix-ups and outlier detection, as well as real-time quality management strategies [86–90]. both clustering-and classification-based Ml models have been proposed for detecting wrong blood in tube (wbIt) errors, which occur when a…”
Tortosa-Carreres, J., Vañó-Bellver, A., Martínez-Cerezuela, A., Fuster, Ó., García-Ruiz, L., Rodríguez-Romero, E., Sierra‐Rivera, A., Comes-Raga, A., Cátedra, C., Garisto, V. T., et al. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0564 · Cited by 2
“Importantly, studies by Farrell and colleagues have consistently demonstrated that machine learning outperforms human assessment in detecting such discrepancies [9, 13, 14].”
InfluentialSürmeli, B. G., Staritzbichler, R., Ringel, C., Al-Dakkak, S., Dörksen, H., & Kaiser, T. (2025) · Journal of Personalized Medicine · doi:10.3390/jpm15090404 · Cited by 1
“[15] incorporated patient metadata such as age and sex; ref.”
InfluentialHejles, R. A. (2024) · Review of Contemporary Philosophy · Cited by 1
Learning to Defer to A Population with Limited Demonstrations
Ramgolam, N. (2025) · International Conference on Digital Image Computing: Techniques and Applications (DICTA) · doi:10.1109/dicta68720.2025.11302495
“Recent advances in AI systems have achieved near-human or superhuman performance across diverse fields, such as computer vision [1] and medical image analysis [2]–[5].”
Mislabel Identification Using Transfer Learning-Based Ensemble Method
Islam, M. S., Kim, M. J., & Dutta, P. (2026) · IEEE Access · doi:10.1109/access.2026.3683309
“In medical diagnostics, any misla-bels in datasets used for disease identification or treatment planning can lead to incorrect predictions, compromising patient safety and health [5], [6], [7].”
Trad, F. S., Doghman, J. H., Sayegh, S. G., Chehab, A., & Assaf, N. (2026) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2026.e00539
“Similarly, other studies have reported successful integration of machine learning models in clinical laboratories to assist in QMS planning and achieve an enhanced reliability [9,10].”
Digital Biobanking in the Era of Artificial Intelligence
Dey, P. (2026) · Biopreservation and Biobanking · doi:10.1177/19475535261474367
Jaibain, Y. A. A. (2024) · Review of Contemporary Philosophy
Metadata
- Authors
- Farrell, C.-J.
- Affiliations
- Nepean Hospital (AU)
- Corresponding author
- Farrell, Christopher-John
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2021-07-16
- Volume
- 58
- Issue
- 6
- Pages
- 650-652
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W3176752500
- Cited by
- 35
- References
- 5
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 7 · 2023: 5 · 2022: 8 · 2021: 1
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Annals of Clinical Biochemistry International Journal of Laboratory Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
- Keywords
- patient identification errors, machine learning, artificial neural networks, human performance comparison, delta check, electrolytes, urea and creatinine, clinical laboratory automation
- MeSH terms
- Machine Learning, Laboratories, Clinical, Algorithms, Computer Simulation, Humans, Logistic Models, Neural Networks, Computer, Support Vector Machine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.