Reference Values for Analytes of 24-H Urine Collections Known to Be Complete
The DOI matches its Crossref record.
Abstract
One hundred and twenty two 24-h urine collections were obtained from a representative sample of men and women in the general population aged 25–44 years. The collections were verified for their completeness by urine recovery of oral doses of para-amino benzoic acid. Means (with 0·95 reference intervals) for both sexes for 24-h urinary output were determined for nitrogen, urea, creatinine, urate, ammonia, sodium, potassium, volume, and pH. Within person variation in nitrogen, urea, creatinine, ammonia, sodium and potassium was estimated for a consecutive 28-day series of 24-h urine collections for eight individuals. Within person variation was greatest for sodium and least for creatinine. These differences when compared with the between person variation in the analytes studied have implications for the precision with which a result from a single specimen can be used to place an individual within a distribution of values for epidemiological purposes. In clinical biochemistry, the population results reported here should be appropriate as a reference base for comparison with individual patient results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Subar, A. F. (2003) · American Journal of Epidemiology · doi:10.1093/aje/kwg092 · Cited by 1,070
Bingham, S. (1997) · International Journal of Epidemiology · doi:10.1093/ije/26.suppl_1.s137 · Cited by 634
Self-citationKroke, A., Klipstein-Grobusch, K., Voss, S., Möseneder, J., Thielecke, F., Noack, R., & Boeing, H. (1999) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/70.4.439 · Cited by 550
Remer, T., Neubert, A., & Maser-Gluth, C. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/75.3.561 · Cited by 394
Bingham, S. A., Cassidy, A., Cole, T. J., Welch, A., Runswick, S. A., Black, A. E., Thurnham, D., Bates, C., Khaw, K. T., Key, T. J. A., et al. (1995) · British Journal of Nutrition · doi:10.1079/bjn19950057 · Cited by 377
“Although the day-today variation in urine K excretion is greater than that in urine N (Bingham et al. 1988) it is found to a greater extent in some different foods, for example vegetables, and therefore is a useful additional validation marker in dietary surveys.”
Self-citation
Metadata
- Authors
- Bingham, S. A., Williams, R., Cole, T. J., Price, C. P., & Cummings, J. H.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 1988-11
- Volume
- 25
- Issue
- 6
- Pages
- 610-619
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W2074707768
- Cited by
- 138
- References
- 0
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reference Values for Analytes of 24-H Urine Collections Known to Be Complete. https://app.cochat.ai/papers/10.1177/000456328802500603
- The paper
- Bingham, S. A., Williams, R., Cole, T. J., Price, C. P., & Cummings, J. H. (1988). Reference Values for Analytes of 24-H Urine Collections Known to Be Complete. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1177/000456328802500603
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.