Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 321

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Analytical Evaluation of Particle-Enhanced Immunonephelometric Assays for C-Reactive Protein, Serum Amyloid a and Mannose-Binding Protein in Human Serum

Ledue, Thomas B, Weiner, Debra L, Sipe, Jean D, Poulin, Sue E, Collins, Marilyn F, Rifai, Nader·1998·Annals of Clinical Biochemistry: International Journal of Laboratory Medicine

Abstract

Against a background of growing interest in more sensitive assays for quantifying various acute phase proteins, we evaluated the performance of recently developed tests for C-reactive protein (CRP), serum amyloid A (SAA) and mannose-binding protein (MBP) on the Behring nephelometer II (BN II). Sample results outside the calibration ranges of 3·5 to 220 mg/L for CRP, 3·3 to 215 mg/L for SAA and 0·09 to 5·6 mg/L for MBP were automatically re-measured at another dilution. The lower limits of detection were 0·01, 0·7 and 0·01 mg/L for CRP, SAA and MBP, respectively. The coefficients of variation (CV) for intra- ( n ⩾ 20) and inter- ( n ⩾ 15) assay precision were < 5·2% and < 8·5%, respectively, for the three proteins at concentrations representing low, normal and high. Linearity for each method was within 5% of the expected values throughout the calibration range. We observed no significant interference from bilirubin (up to 300 mg/L) or haemoglobin (up to 10 g/L) for the three tests. Method comparison studies performed for CRP and SAA yielded the following results: y (CRP on BN II) = 0·75 x (ELISA, Hemagen) −0·25 mg/L ( r = 0·981, S y/x = 2·1 mg/L; y (SAA on BN II) = 1·44 x (ELISA, Hemagen) −9·9 mg/L ( r = 0·972, S y/x = 6·9 mg/L), where ELISA is enzyme-linked immunosorbent assay. Reference intervals established in 261 adult blood donors (aged 36·2 ± 9·0 years) were found to be log-normal with 2·5th, 50th and 97·5th centiles of < 0·17, 100 and 10·1 mg/L for CRP, < 0·84, 2·10 and 9·70 mg/L for SAA; and 0·30, 1·28 and 4·10 mg/L for MBP. We observed no relationship with CRP concentration and age; however, SAA levels increased with age while MBP levels decreased. The BN II provides a simple, rapid and sensitive system for measuring CRP, SAA and MBP in human serum.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/000456329803500607

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 321

Metadata

Authors
Ledue, T. B., Weiner, D. L., Sipe, J. D., Poulin, S. E., Collins, M. F., & Rifai, N.
Venue
Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
Published
1998-11
Volume
35
Issue
6
Pages
745-753
ISSN
  • 0004-5632 (ISSN-L)
  • 1758-1001
OpenAlex
W1998667286
Cited by
321
References
29
FWCI
6.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analytical Evaluation of Particle-Enhanced Immunonephelometric Assays for C-Reactive Protein, Serum Amyloid a and Mannose-Binding Protein in Human Serum. https://app.cochat.ai/papers/10.1177/000456329803500607
The paper
Ledue, T. B., Weiner, D. L., Sipe, J. D., Poulin, S. E., Collins, M. F., & Rifai, N. (1998). Analytical Evaluation of Particle-Enhanced Immunonephelometric Assays for C-Reactive Protein, Serum Amyloid a and Mannose-Binding Protein in Human Serum. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1177/000456329803500607

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.