The DOI matches its Crossref record.
Shear linear behavior of brain tissue over a large frequency range
Abstract
The literature review about the shear linear properties of brain tissue reveals both a large discrepancy in the existing data and a crucial lack of information at high frequencies associated with traffic road and non‐penetrating ballistic impacts. The purpose of this study is to clarify and to complement the linear material characterisation of brain tissue. New data at small strains and high frequencies were obtained from oscillatory experiments. The tests were performed on thin porcine white matter samples (corona radiata) using an original custom‐designed oscillatory shear testing device. At 37°C, the results showed that the mean storage modulus (G′) and the mean loss modulus (G″) increased with the frequency (0.1 to 6310 Hz) from 2.1±0.9 kPa to 16.8±2.0 kPa and from 0.4±0.2 kPa to 18.7±2.3 kPa respectively. The reliability of these new dynamic data was checked over a partially common frequency range by conducting similar experiments using a standard rheometer (Bohlin C‐VOR 150). Data were also compared in the time field. From these experiments, the relaxation modulus (G(t)) was found to decrease from 24.4±2.1 kPa to 1.0±0.3 kPa between 10−5 s and 270 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effects of extracellular matrix viscoelasticity on cellular behaviour
Chaudhuri, O., Cooper-White, J., Janmey, P. A., Mooney, D. J., & Shenoy, V. B. (2020) · Nature · doi:10.1038/s41586-020-2612-2 · Cited by 2,224
Soft biological materials and their impact on cell function
Levental, I., Georges, P. C., & Janmey, P. A. (2007) · Soft Matter · doi:10.1039/b610522j · Cited by 905
Bio-inspired soft robotics: Material selection, actuation, and design
Coyle, S., Majidi, C., LeDuc, P., & Hsia, K. J. (2018) · Extreme Mechanics Letters · doi:10.1016/j.eml.2018.05.003 · Cited by 400
Klatt, D., Hamhaber, U., Asbach, P., Braun, J., & Sack, I. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/24/006 · Cited by 333
Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastography
Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., & Braun, J. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1189 · Cited by 316
Metadata
- Authors
- Nicolle, S., Lounis, M., Willinger, R., & Palierne, J. ‐.
- Venue
- Biorheology: The Official Journal of the International Society of Biorheology
- Publisher
- SAGE Publications
- Published
- 2005-05
- Volume
- 42
- Issue
- 3
- Pages
- 209-223
- ISSN
- 0006-355X (ISSN-L)
- 1878-5034
- OpenAlex
- W1920490291
- Cited by
- 176
- References
- 0
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shear linear behavior of brain tissue over a large frequency range. https://app.cochat.ai/papers/10.1177/0006355x2005042003003
- The paper
- Nicolle, S., Lounis, M., Willinger, R., & Palierne, J. ‐. (2005). Shear linear behavior of brain tissue over a large frequency range. Biorheology: The Official Journal of the International Society of Biorheology. https://doi.org/10.1177/0006355x2005042003003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.