Shear linear behavior of brain tissue over a large frequency range
The DOI matches its Crossref record.
Abstract
The literature review about the shear linear properties of brain tissue reveals both a large discrepancy in the existing data and a crucial lack of information at high frequencies associated with traffic road and non‐penetrating ballistic impacts. The purpose of this study is to clarify and to complement the linear material characterisation of brain tissue. New data at small strains and high frequencies were obtained from oscillatory experiments. The tests were performed on thin porcine white matter samples (corona radiata) using an original custom‐designed oscillatory shear testing device. At 37°C, the results showed that the mean storage modulus (G′) and the mean loss modulus (G″) increased with the frequency (0.1 to 6310 Hz) from 2.1±0.9 kPa to 16.8±2.0 kPa and from 0.4±0.2 kPa to 18.7±2.3 kPa respectively. The reliability of these new dynamic data was checked over a partially common frequency range by conducting similar experiments using a standard rheometer (Bohlin C‐VOR 150). Data were also compared in the time field. From these experiments, the relaxation modulus (G(t)) was found to decrease from 24.4±2.1 kPa to 1.0±0.3 kPa between 10−5 s and 270 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effects of extracellular matrix viscoelasticity on cellular behaviour
Chaudhuri, O., Cooper-White, J., Janmey, P. A., Mooney, D. J., & Shenoy, V. B. (2020) · Nature · doi:10.1038/s41586-020-2612-2 · Cited by 2,224
Soft biological materials and their impact on cell function
Levental, I., Georges, P. C., & Janmey, P. A. (2007) · Soft Matter · doi:10.1039/b610522j · Cited by 905
Predictors for Traumatic Brain Injuries Evaluated through Accident Reconstructions
Kleiven, S. (2007) · SAE Technical Paper Series · doi:10.4271/2007-22-0003 · Cited by 670
Mechanical characterization of brain tissue in compression at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.01.022 · Cited by 426
In vivo brain viscoelastic properties measured by magnetic resonance elastography
Green, M. A., Bilston, L. E., & Sinkus, R. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1254 · Cited by 418
Bio-inspired soft robotics: Material selection, actuation, and design
Coyle, S., Majidi, C., LeDuc, P., & Hsia, K. J. (2018) · Extreme Mechanics Letters · doi:10.1016/j.eml.2018.05.003 · Cited by 400
Mao, H., Zhang, L., Jiang, B., Genthikatti, V. V., Jin, X., Zhu, F., Makwana, R., Gill, A., Jandir, G., Singh, A., et al. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4025101 · Cited by 369
Fifty years of brain tissue mechanical testing: From in vitro to in vivo investigations
Chatelin, S., Constantinesco, A., & Willinger, R. (2010) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.3233/bir-2010-0576 · Cited by 342
Self-citationKlatt, D., Hamhaber, U., Asbach, P., Braun, J., & Sack, I. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/24/006 · Cited by 333
Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastography
Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., & Braun, J. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1189 · Cited by 316
Mechanical Heterogeneity of the Rat Hippocampus Measured by Atomic Force Microscope Indentation
Elkin, B. S., Azeloglu, E. U., Costa, K. D., & Morrison III, B. (2007) · Journal of Neurotrauma · doi:10.1089/neu.2006.0169 · Cited by 316
Feng, Y., Okamoto, R. J., Namani, R., Genin, G. M., & Bayly, P. V. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.04.007 · Cited by 316
Mechanical properties of brain tissue by indentation: Interregional variation
van Dommelen, J. A. W., van der Sande, T. P. J., Hrapko, M., & Peters, G. W. M. (2010) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2009.09.001 · Cited by 283
Ghajari, M., Hellyer, P. J., & Sharp, D. J. (2017) · Brain · doi:10.1093/brain/aww317 · Cited by 280
Compression stiffening of brain and its effect on mechanosensing by glioma cells
Pogoda, K., Chin, L., Georges, P. C., Byfield, F. J., Bucki, R., Kim, R., Weaver, M., Wells, R. G., Marcinkiewicz, C., & Janmey, P. A. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/075002 · Cited by 216
Mechanical characterization of brain tissue in simple shear at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.07.017 · Cited by 196
“…al., 1999; 2000a; 2000b; 2004; Darvish and Crandall, 2001; Fallenstein et al., 1969; Garo et al., 2007; Hirakawa et al., 1981; Hrapko et al., 2008; Nicolle et al., 2004; 2005; Prange and Margulies, 2002; Shen et al., 2006; Shuck and Advani, 1972; Thibault and Margulies, 1998) and various other…”
BackgroundGiordano, C., & Kleiven, S. (2014) · SAE Technical Paper Series · doi:10.4271/2014-22-0002 · Cited by 192
The Influence of Test Conditions on Characterization of the Mechanical Properties of Brain Tissue
Hrapko, M., van Dommelen, J. A. W., Peters, G. W. M., & Wismans, J. S. H. M. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2907746 · Cited by 184
Metadata
- Authors
- Nicolle, S., Lounis, M., Willinger, R., & Palierne, J. ‐.
- Venue
- Biorheology: The Official Journal of the International Society of Biorheology
- Publisher
- SAGE Publications
- Published
- 2005-05
- Volume
- 42
- Issue
- 3
- Pages
- 209-223
- ISSN
- 0006-355X (ISSN-L)
- 1878-5034
- OpenAlex
- W1920490291
- Cited by
- 176
- References
- 0
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.