Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastography

Sack, Ingolf, Beierbach, Bernd, Hamhaber, Uwe, Klatt, Dieter, Braun, Jürgen·2008·NMR in Biomedicine

Abstract

The purpose of this work was to develop magnetic resonance elastography (MRE) for the fast and reproducible measurement of spatially averaged viscoelastic constants of living human brain. The technique was based on a phase‐sensitive echo planar imaging acquisition. Motion encoding was orthogonal to the image plane and synchronized to intracranial shear vibrations at driving frequencies of 25 and 50 Hz induced by a head‐rocker actuator. Ten time‐resolved phase‐difference wave images were recorded within 60 s and analyzed for shear stiffness and shear viscosity. Six healthy volunteers (six men; mean age 34.5 years; age range 25–44 years) underwent 23–39 follow‐up MRE studies over a period of 6 months. Interindividual mean ± SD shear moduli and shear viscosities were found to be 1.17 ± 0.03 kPa and 3.1 ± 0.4 Pas for 25 Hz and 1.56 ± 0.07 kPa and 3.4 ± 0.2 Pas for 50 Hz, respectively (P ≤ 0.01). The intraindividual range of shear modulus data was 1.01–1.31 kPa (25 Hz) and 1.33–1.77 kPa (50 Hz). The observed modulus dispersion indicates a limited applicability of Voigt's model to explain viscoelastic behavior of brain parenchyma within the applied frequency range. The narrow distribution of data within small confidence intervals demonstrates excellent reproducibility of the experimental protocol. The results are necessary as reference data for future comparisons between healthy and pathological human brain viscoelastic data. Copyright © 2007 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nbm.1189

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 41 references

Cited by

See all 316

Metadata

Authors
Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., & Braun, J.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
2007-07-05
Volume
21
Issue
3
Pages
265-271
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W1980151067
Cited by
316
References
41
FWCI
12.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastography. https://app.cochat.ai/papers/10.1002/nbm.1189
The paper
Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., & Braun, J. (2008). Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastography. NMR in Biomedicine. https://doi.org/10.1002/nbm.1189

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.