Uniform tissues engineered by seeding and culturing cells in 3D scaffolds under perfusion at defined oxygen tensions
Open accessThe DOI matches its Crossref record.
Abstract
In this work, we assessed whether culture of uniformly seeded chondrocytes under direct perfusion, which supplies the cells with normoxic oxygen levels, can maintain a uniform distribution of viable cells throughout porous scaffolds several milimeters in thickness, and support the development of uniform tissue grafts. An integrated bioreactor system was first developed to streamline the steps of perfusion cell seeding of porous scaffolds and perfusion culture of the cell-seeded scaffolds. Oxygen tensions in perfused constructs were monitored by in-line oxygen sensors incorporated at the construct inlet and outlet. Adult human articular chondrocytes were perfusion-seeded into 4.5 mm thick foam scaffolds at a rate of 1 mm/s. Cell-seeded foams were then either cultured statically in dishes or further cultured under perfusion at a rate of 100 μm/s for 2 weeks. Following perfusion seeding, viable cells were uniformly distributed throughout the foams. Constructs subsequently cultured statically were highly heterogeneous, with cells and matrix concentrated at the construct periphery. In contrast, constructs cultured under perfusion were highly homogeneous, with uniform distributions of cells and matrix. Oxygen tensions of the perfused medium were maintained near normoxic levels (inlet ≅ 20%, outlet > 15%) at all times of culture. We have demonstrated that perfusion culture of cells seeded uniformly within porous scaffolds, at a flow rate maintaining a homogeneous oxygen supply, supports the development of uniform engineering tissue grafts of clinically relevant thicknesses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Engineered Microenvironments for Controlled Stem Cell Differentiation
Burdick, J. A., & Vunjak-Novakovic, G. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0131 · Cited by 485
“60,69 An attractive feature of the perfusion bioreactors is that the whole process occurs in one single sequence (Fig.”
Bone marrow–on–a–chip replicates hematopoietic niche physiology in vitro
Torisawa, Y.-S., Spina, C. S., Mammoto, T., Mammoto, A., Weaver, J. C., Tat, T., Collins, J. J., & Ingber, D. E. (2014) · Nature Methods · doi:10.1038/nmeth.2938 · Cited by 451
Osteochondral tissue engineering
Martin, I., Miot, S., Barbero, A., Jakob, M., & Wendt, D. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.03.008 · Cited by 378
Self-citationMajor biological obstacles for persistent cell-based regeneration of articular cartilage
Steinert, A. F., Ghivizzani, S. C., Rethwilm, A., Tuan, R. S., Evans, C. H., & Nöth, U. (2007) · Arthritis Research & Therapy · doi:10.1186/ar2195 · Cited by 321
Bone tissue engineering bioreactors: Dynamic culture and the influence of shear stress
Yeatts, A. B., & Fisher, J. P. (2011) · Bone · doi:10.1016/j.bone.2010.09.138 · Cited by 298
Hypoxia in Static and Dynamic 3D Culture Systems for Tissue Engineering of Bone
Volkmer, E., Drosse, I., Otto, S., Stangelmayer, A., Stengele, M., Kallukalam, B. C., Mutschler, W., & Schieker, M. (2008) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0231 · Cited by 285
The Roles of Hypoxia in the In Vitro Engineering of Tissues
Malda, J., Klein, T. J., & Upton, Z. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0417 · Cited by 282
Cartilage tissue engineering for degenerative joint disease☆
NESIC, D., WHITESIDE, R., BRITTBERG, M., WENDT, D., MARTIN, I., & MAINILVARLET, P. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.01.012 · Cited by 241
Self-citationTissue engineering for bone defect healing: An update on a multi-component approach
Drosse, I., Volkmer, E., Capanna, R., Biase, P. D., Mutschler, W., & Schieker, M. (2008) · Injury · doi:10.1016/s0020-1383(08)70011-1 · Cited by 202
Supply of Nutrients to Cells in Engineered Tissues
Rouwkema, J., Koopman, B. F. J. M., Blitterswijk, C. A. V., Dhert, W. J. A., & Malda, J. (2009) · Biotechnology and Genetic Engineering Reviews · doi:10.5661/bger-26-163 · Cited by 202
“In turn, this leads to inhomogeneous tissue formation, with the bulk of matrix in the periphery and little in the center (Malda et al. 2004; Wendt et al. 2006).”
BackgroundToward modeling the bone marrow niche using scaffold-based 3D culture systems
Di Maggio, N., Piccinini, E., Jaworski, M., Trumpp, A., Wendt, D. J., & Martin, I. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.041 · Cited by 163
Self-citationLiu, Z., Tamaddon, M., Gu, Y., Yu, J., Xu, N., Gang, F., Sun, X., & Liu, C. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00104 · Cited by 37
“Cell adhesion to implant material could be one of the key steps for bone and cartilage regeneration (Wendt et al., 2006; Santoro et al., 2010).”
Background
Metadata
- Authors
- Wendt, D., Stroebel, S., Jakob, M., John, G. T., & Martin, I.
- Venue
- Biorheology: The Official Journal of the International Society of Biorheology
- Publisher
- SAGE Publications
- Published
- 2006-05
- Volume
- 43
- Issue
- 3-4
- Pages
- 481-488
- ISSN
- 0006-355X (ISSN-L)
- 1878-5034
- OpenAlex
- W2108217947
- Cited by
- 145
- References
- 0
- FWCI
- 9.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.