Volume flow and wall shear stress quantification in the human conjunctival capillaries and post-capillary venules in vivo
Abstract
Understanding the mathematical relationships of volume blood flow and wall shear stress with respect to microvessel diameter is necessary for the study of vascular design. Here, for the first time, volume flow and wall shear stress were quantified from axial red blood cell velocity measurements in 104 conjunctival microvessels of 17 normal human volunteers. Measurements were taken with a slit lamp based imaging system from the post capillary side of the bulbar conjunctiva in microvessel diameters ranging from 4 to 24 micrometers. The variation of the velocity profile with diameter was taken into account by using a profile factor function. Volume flow ranged from 5 to 462 pl/s with a mean value of 102 pl/s and gave a second power law best fitting line (r=0.97) deviating significantly from the third power law relation with diameter. The estimated wall shear stress declined hyperbolically (r=0.93) from a maximum of 9.55 N/m 2 at the smallest capillaries, down to a minimum of 0.28 N/m 2 at the higher diameter post capillary venules. The mean wall shear stress value for all microvessels was 1.54 N/m 2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Overcoming the Blood–Brain Barrier: The Role of Nanomaterials in Treating Neurological Diseases
Furtado, D., Björnmalm, M., Ayton, S., Bush, A. I., Kempe, K., & Caruso, F. (2018) · Advanced Materials · doi:10.1002/adma.201801362 · Cited by 708
The blood-brain barrier: an engineering perspective
Wong, A. D., Ye, M., Levy, A. F., Rothstein, J. D., Bergles, D. E., & Searson, P. C. (2013) · Frontiers in Neuroengineering · doi:10.3389/fneng.2013.00007 · Cited by 662
The role of shear stress in Blood-Brain Barrier endothelial physiology
Cucullo, L., Hossain, M., Puvenna, V., Marchi, N., & Janigro, D. (2011) · BMC Neuroscience · doi:10.1186/1471-2202-12-40 · Cited by 438
Organotypic liver culture models: meeting current challenges in toxicity testing
LeCluyse, E. L., Witek, R. P., Andersen, M. E., & Powers, M. J. (2012) · Critical Reviews in Toxicology · doi:10.3109/10408444.2012.682115 · Cited by 363
Scaling and systems biology for integrating multiple organs-on-a-chip
Wikswo, J. P., Curtis, E. L., Eagleton, Z. E., Evans, B. C., Kole, A., Hofmeister, L. H., & Matloff, W. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50243k · Cited by 309
Metadata
- Authors
- Koutsiaris, A. G., Tachmitzi, S. V., Batis, N., Kotoula, M. G., Karabatsas, C. H., Tsironi, E., & Chatzoulis, D. Z.
- Venue
- Biorheology: The Official Journal of the International Society of Biorheology
- Publisher
- SAGE Publications
- Published
- 2007-09
- Volume
- 44
- Issue
- 5-6
- Pages
- 375-386
- ISSN
- 0006-355X (ISSN-L)
- 1878-5034
- OpenAlex
- W1678960821
- Cited by
- 244
- References
- 0
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volume flow and wall shear stress quantification in the human conjunctival capillaries and post-capillary venules in vivo. https://app.cochat.ai/papers/10.1177/0006355x2007044005006008
- The paper
- Koutsiaris, A. G., Tachmitzi, S. V., Batis, N., Kotoula, M. G., Karabatsas, C. H., Tsironi, E., & Chatzoulis, D. Z. (2007). Volume flow and wall shear stress quantification in the human conjunctival capillaries and post-capillary venules in vivo. Biorheology: The Official Journal of the International Society of Biorheology. https://doi.org/10.1177/0006355x2007044005006008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.