Volume flow and wall shear stress quantification in the human conjunctival capillaries and post-capillary venules in vivo
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Understanding the mathematical relationships of volume blood flow and wall shear stress with respect to microvessel diameter is necessary for the study of vascular design. Here, for the first time, volume flow and wall shear stress were quantified from axial red blood cell velocity measurements in 104 conjunctival microvessels of 17 normal human volunteers. Measurements were taken with a slit lamp based imaging system from the post capillary side of the bulbar conjunctiva in microvessel diameters ranging from 4 to 24 micrometers. The variation of the velocity profile with diameter was taken into account by using a profile factor function. Volume flow ranged from 5 to 462 pl/s with a mean value of 102 pl/s and gave a second power law best fitting line (r=0.97) deviating significantly from the third power law relation with diameter. The estimated wall shear stress declined hyperbolically (r=0.93) from a maximum of 9.55 N/m 2 at the smallest capillaries, down to a minimum of 0.28 N/m 2 at the higher diameter post capillary venules. The mean wall shear stress value for all microvessels was 1.54 N/m 2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
The Physiological Principle of Minimum Work: I. The Vascular System and the Cost of Blood Volume
Murray, C. D. (1926) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.12.3.207 · Cited by 2,087 · cited 2×
“7 the constant K as originally proposed by Murray [25] for capillaries.”
Resistance to blood flow in microvessels in vivo.
Pries, A. R., Secomb, T. W., Gessner, T., Sperandio, M. B., Gross, J. F., & Gaehtgens, P. (1994) · Circulation Research · doi:10.1161/01.res.75.5.904 · Cited by 616 · cited 3×
“In addition, the in vivo viscosity law [28] was used for the estimation of η in Eq.”
BackgroundMethodReneman, R. S., Arts, T., & Hoeks, A. P. G. (2006) · Journal of Vascular Research · doi:10.1159/000091648 · Cited by 431
Microvascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414 · cited 2×
“6, a steep decrease (approximately 17 times, from the best fit line) of WSS values from capillaries to post capillary venules is seen, that has also been observed in other animal tissues [21].”
InfluentialWindberger, U., Bartholovitsch, A., Plasenzotti, R., Korak, K. J., & Heinze, G. (2003) · Experimental Physiology · doi:10.1113/eph8802496 · Cited by 339 · cited 1×
“) equal to 22.1% and a plasma viscosity = 1.24 cP [38,41].”
InfluentialDesign Principles of Vascular Beds
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1995) · Circulation Research · doi:10.1161/01.res.77.5.1017 · Cited by 321 · cited 5×
“Velocity measurements of erythrocyte motion in the lowest diameter microvessels have been performed in the past by various researchers in various animal tissues [9,11,30,34,36,39].”
InfluentialRobin Fahraeus: evolution of his concepts in cardiovascular physiology
Goldsmith, H. L., Cokelet, G. R., & Gaehtgens, P. (1989) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1989.257.3.h1005 · Cited by 231 · cited 3×
“It should be noted that for the case of single file flow, the relation between V ax and V s can be derived from the Fåhraeus effect [6].”
Scaling laws of vascular trees: of form and function
Kassab, G. S. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00579.2005 · Cited by 221 · cited 2×
“It should also be noted that our results do not contradict Kassab’s work [13] since it is stated clearly there that the “stem-crown” theory is valid only for an arterial or venous tree structure down to the first capillary bifurcation and hence not to the smallest microvessels (precapillary…”
Long, D. S., Smith, M. L., Pries, A. R., Ley, K., & Damiano, E. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402937101 · Cited by 210
Cited by
Overcoming the Blood–Brain Barrier: The Role of Nanomaterials in Treating Neurological Diseases
Furtado, D., Björnmalm, M., Ayton, S., Bush, A. I., Kempe, K., & Caruso, F. (2018) · Advanced Materials · doi:10.1002/adma.201801362 · Cited by 708
The blood-brain barrier: an engineering perspective
Wong, A. D., Ye, M., Levy, A. F., Rothstein, J. D., Bergles, D. E., & Searson, P. C. (2013) · Frontiers in Neuroengineering · doi:10.3389/fneng.2013.00007 · Cited by 662
“Typical time averaged values of shear stress are 4–30 dynes cm−2 in the arterial circulation and 1–4 dynes cm−2 in the venous circulation (Turitto, 1982; Kamiya et al., 1984; Papaioannou and Stefanadis, 2005; Koutsiaris et al., 2007; Dolan et al., 2013).”
BackgroundThe role of shear stress in Blood-Brain Barrier endothelial physiology
Cucullo, L., Hossain, M., Puvenna, V., Marchi, N., & Janigro, D. (2011) · BMC Neuroscience · doi:10.1186/1471-2202-12-40 · Cited by 438
Organotypic liver culture models: meeting current challenges in toxicity testing
LeCluyse, E. L., Witek, R. P., Andersen, M. E., & Powers, M. J. (2012) · Critical Reviews in Toxicology · doi:10.3109/10408444.2012.682115 · Cited by 363
Scaling and systems biology for integrating multiple organs-on-a-chip
Wikswo, J. P., Curtis, E. L., Eagleton, Z. E., Evans, B. C., Kole, A., Hofmeister, L. H., & Matloff, W. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50243k · Cited by 309
In Vitro Blood–Brain Barrier Models: Current and Perspective Technologies
Naik, P., & Cucullo, L. (2012) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23022 · Cited by 288
In Vitro Models of the Blood-Brain Barrier
Neuhaus, W. (2020) · Handbook of Experimental Pharmacology · doi:10.1007/164_2020_370 · Cited by 236
In-vitro blood-brain barrier models for drug screening and permeation studies: an overview
Bagchi, S., Chhibber, T., Lahooti, B., Verma, A., Borse, V., & Jayant, R. D. (2019) · Drug Design, Development and Therapy · doi:10.2147/dddt.s218708 · Cited by 234
“51 To maintain the stable microenvironment, a gas-permeable tubing system was used for the exchange of O 2 and CO 2 .”
Linville, R. M., DeStefano, J. G., Sklar, M. B., Xu, Z., Farrell, A. M., Bogorad, M. I., Chu, C., Walczak, P., Cheng, L., Mahairaki, V., et al. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.10.023 · Cited by 199
“limited supporting cells, and a wall shear stress o f 1 - 4 dyne cm.(18-21) PCVs are the site for”
Cell-Culture Models of the Blood–Brain Barrier
He, Y., Yao, Y., Tsirka, S. E., & Cao, Y. (2014) · Stroke · doi:10.1161/strokeaha.114.005427 · Cited by 194
Potential role of size and hemodynamics in the efficacy of vascular-targeted spherical drug carriers
Charoenphol, P., Huang, R. B., & Eniola-Adefeso, O. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.007 · Cited by 191
Medium throughput breathing human primary cell alveolus-on-chip model
Stucki, J. D., Hobi, N., Galimov, A., Stucki, A. O., Schneider-Daum, N., Lehr, C.-M., Huwer, H., Frick, M., Funke-Chambour, M., Geiser, T., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-32523-x · Cited by 190
Piezo1 mediates angiogenesis through activation of MT1-MMP signaling
Kang, H., Hong, Z., Zhong, M., Klomp, J., Bayless, K. J., Mehta, D., Karginov, A. V., Hu, G., & Malik, A. B. (2019) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00346.2018 · Cited by 183
“The WSS level of 5 dyne/cm(2) was chosen as it is typical in venules (18, 25, 26).”
MethodBenchmarking in vitro tissue-engineered blood–brain barrier models
DeStefano, J. G., Jamieson, J. J., Linville, R. M., & Searson, P. C. (2018) · Fluids and Barriers of the CNS · doi:10.1186/s12987-018-0117-2 · Cited by 142
Grifno, G. N., Farrell, A. M., Linville, R. M., Arevalo, D., Kim, J. H., Gu, L., & Searson, P. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-50193-1 · Cited by 112
Ta, H. T., Truong, N. P., Whittaker, A. K., Davis, T. P., & Peter, K. (2018) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2017.1316262 · Cited by 105
Toward the broad adoption of 3D tumor models in the cancer drug pipeline
Cox, M. C., Reese, L. M., Bickford, L. R., & Verbridge, S. S. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00172 · Cited by 80
Recent developments in nanomaterial-based shear-sensitive drug delivery systems
Wang, Y., Pisapati, A. V., Zhang, X. F., & Cheng, X. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002196 · Cited by 44
Broadly inhibitory antibodies to severe malaria virulence proteins
Reyes, R. A., Raghavan, S. S. R., Hurlburt, N. K., Introini, V., Bol, S., Kana, I. H., Jensen, R. W., Martinez-Scholze, E., Gestal-Mato, M., López-Gutiérrez, B., et al. (2024) · Nature · doi:10.1038/s41586-024-08220-3 · Cited by 35
Metadata
- Authors
- Koutsiaris, A. G., Tachmitzi, S. V., Batis, N., Kotoula, M. G., Karabatsas, C. H., Tsironi, E., & Chatzoulis, D. Z.
- Venue
- Biorheology: The Official Journal of the International Society of Biorheology
- Publisher
- SAGE Publications
- Published
- 2007-09
- Volume
- 44
- Issue
- 5-6
- Pages
- 375-386
- ISSN
- 0006-355X (ISSN-L)
- 1878-5034
- OpenAlex
- W1678960821
- Cited by
- 244
- References
- 25
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.