Biomechanical Evaluation of Osseous Implants Having Different Surface Topographies in Rats
Abstract
Biomechanical and biological factors can co-dependently influence the establishment of implant-tissue integration; thus, concurrent evaluation of these factors should provide a better understanding of osseointegration. This study aimed to establish and validate an in vivo rat model frequently used in molecular/cellular biology for implant biomechanical studies. We tested the hypotheses that the implant push-in test assesses the degree of osseointegration by the breakpoint load at the implant-tissue interface and that it sensitively differentiates between the effects of different implant surface topographies. The implant push-in test, which produces a consistent load-displacement measurement, was used to test miniature cylindrical titanium implants placed at the distal edge of the adult rat femur. The push-in test values obtained at each post-implantation healing point (weeks 0, 2, 4, and 8) significantly increased in a time-dependent manner. The implant surface after the push-in test was associated with remnant tissues containing host-derived elements, such as calcium, phosphate, and sulfate. In this model, acid-etched implants (average roughness, 0.159 μm) showed significantly greater push-in test values than did turned implants (average roughness, 0.063 μm) throughout the experimental period (p < 0.0001). These results support the validity of the push-in test in rats, which may be used as a rapid and sensitive biomechanical assay system for implant osseointegration research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basic biomechanical measurements of bone: A tutorial
Turner, C. H., & Burr, D. B. (1993) · Bone · doi:10.1016/8756-3282(93)90081-k · Cited by 1,666
Cited by
Effects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462
The effect of ultraviolet functionalization of titanium on integration with bone
Aita, H., Hori, N., Takeuchi, M., Suzuki, T., Yamada, M., Anpo, M., & Ogawa, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.11.004 · Cited by 504
Self-citationBasic research methods and current trends of dental implant surfaces
Coelho, P. G., Granjeiro, J. M., Romanos, G. E., Suzuki, M., Silva, N. R. F., Cardaropoli, G., Thompson, V. P., & Lemons, J. E. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31264 · Cited by 359
Cellular behavior on TiO2 nanonodular structures in a micro-to-nanoscale hierarchy model
Kubo, K., Tsukimura, N., Iwasa, F., Ueno, T., Saruwatari, L., Aita, H., Chiou, W.-A., & Ogawa, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.06.021 · Cited by 305
Self-citation
Metadata
- Authors
- Ogawa, T., Ozawa, S., Shih, J.-H., Ryu, K. H., Sukotjo, C., Yang, J.-M., & Nishimura, I.
- Venue
- Journal of Dental Research
- Publisher
- SAGE Publications
- Published
- 2000-11
- Volume
- 79
- Issue
- 11
- Pages
- 1857-1863
- ISSN
- 0022-0345 (ISSN-L)
- 1544-0591
- OpenAlex
- W2126562747
- Cited by
- 172
- References
- 1
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biomechanical Evaluation of Osseous Implants Having Different Surface Topographies in Rats. https://app.cochat.ai/papers/10.1177/00220345000790110701
- The paper
- Ogawa, T., Ozawa, S., Shih, J.-H., Ryu, K. H., Sukotjo, C., Yang, J.-M., & Nishimura, I. (2000). Biomechanical Evaluation of Osseous Implants Having Different Surface Topographies in Rats. Journal of Dental Research. https://doi.org/10.1177/00220345000790110701
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.