The DOI matches its Crossref record.
Mechanism of Adhesion of Polyelectrolyte Cements to Hydroxyapatite
Abstract
The interaction between polyacrylate ions and hydroxyapatite was examined using extraction techniques and infra-red spectroscopy. These studies have shown that polyacrylate ions become irreversibly attached to the surface of hydroxyapatite by displacing existing phosphate ions. The mechanism is not one of simple ion exchange, since calcium ions are displaced by the phosphate ions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Adhesion to Dentin and Physical Properties of a Light-cured Glass-ionomer Liner/Base
Mitra, S. B. (1991) · Journal of Dental Research · doi:10.1177/00220345910700011201 · Cited by 329
Current status of luting agents for fixed prosthodontics
Diaz-Arnold, A. M., Vargas, M. A., & Haselton, D. R. (1999) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(99)70240-4 · Cited by 272
Modifications in Glass Ionomer Cements: Nano-Sized Fillers and Bioactive Nanoceramics
Najeeb, S., Khurshid, Z., Zafar, M., Khan, A., Zohaib, S., Martí, J., Sauro, S., Matinlinna, J., & Rehman, I. (2016) · International Journal of Molecular Sciences · doi:10.3390/ijms17071134 · Cited by 226
“It is a kind of film of tooth debris left behind on the tooth surface following tooth preparation [90].”
Background
Metadata
- Authors
- Wilson, A. D., Prosser, H. J., & Powis, D. M.
- Venue
- Journal of Dental Research
- Publisher
- SAGE Publications
- Published
- 1983-05
- Volume
- 62
- Issue
- 5
- Pages
- 590-592
- ISSN
- 0022-0345 (ISSN-L)
- 1544-0591
- OpenAlex
- W1992865032
- Cited by
- 247
- References
- 0
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanism of Adhesion of Polyelectrolyte Cements to Hydroxyapatite. https://app.cochat.ai/papers/10.1177/00220345830620051801
- The paper
- Wilson, A. D., Prosser, H. J., & Powis, D. M. (1983). Mechanism of Adhesion of Polyelectrolyte Cements to Hydroxyapatite. Journal of Dental Research. https://doi.org/10.1177/00220345830620051801
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.