A Novel Procedure for Pre-embedding Double Immunogold–Silver Labeling at the Ultrastructural Level
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Pre-embedding double immunogold–silver labeling using two ultrasmall gold conjugates has not been attempted previously because a means of distinguishing labels by conjugates of identical sizes was lacking. This study investigated the feasibility of creating a particle size segregation between two ultrasmall gold conjugates through sequential immunogold incubations and silver enhancements. Two primary antibodies, mouse anti-synaptophysin and rabbit anti-glial fibrillary acidic protein (GFAP), were used in the model system. Differentiation of the double labeling was achieved by incubating with one ultrasmall gold conjugate, followed by silver enhancement, and then incubating with the second ultrasmall gold conjugate, followed by additional silver enhancement. This resulted in two groups of silver-enhanced particles: smaller particles enhanced once and larger particles enhanced twice. Electron microscopic examination revealed two readily distinguished populations of gold–silver particles within the appropriate structures, with very little size overlap. The quality of the ultrastructure permitted identification of most subcellular organelles. This procedure provides for the first time a pre-embedding immunogold–silver labeling protocol that allows the precise subcellular co-localization of multiple antigens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feng, Y., Gutekunst, C.-A., Eberhart, D. E., Yi, H., Warren, S. T., & Hersch, S. M. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-05-01539.1997 · Cited by 532
Self-citation
Cited by
Size‐Dependent Cytotoxicity of Gold Nanoparticles
Pan, Y., Neuss, S., Leifert, A., Fischler, M., Wen, F., Simon, U., Schmid, G., Brandau, W., & Jahnen‐Dechent, W. (2007) · Small · doi:10.1002/smll.200700378 · Cited by 1,878
Metal‐based nanoparticles and their toxicity assessment
Schrand, A. M., Rahman, M. F., Hussain, S. M., Schlager, J. J., Smith, D. A., & Syed, A. F. (2010) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.103 · Cited by 753
Cytotoxicity and Immunological Response of Gold and Silver Nanoparticles of Different Sizes
Yen, H., Hsu, S., & Tsai, C. (2009) · Small · doi:10.1002/smll.200900126 · Cited by 635
Energy Dispersive X-ray (EDX) microanalysis: A powerful tool in biomedical research and diagnosis
Scimeca, M., Bischetti, S., Lamsira, H. K., Bonfiglio, R., & Bonanno, E. (2018) · European Journal of Histochemistry · doi:10.4081/ejh.2018.2841 · Cited by 525
Balijepalli, R. C., Foell, J. D., Hall, D. D., Hell, J. W., & Kamp, T. J. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503465103 · Cited by 393
Metadata
- Authors
- Yi, H., Leunissen, J. L. M., Shi, G.-M., Gutekunst, C.-A., & Hersch, S. M.
- Venue
- Journal of Histochemistry & Cytochemistry
- Publisher
- SAGE Publications
- Published
- 2001-03
- Volume
- 49
- Issue
- 3
- Pages
- 279-283
- ISSN
- 0022-1554 (ISSN-L)
- 1551-5044
- OpenAlex
- W2110808439
- Cited by
- 107
- References
- 1
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.