Complete Chromogen Separation and Analysis in Double Immunohistochemical Stains Using Photoshop-based Image Analysis
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Simultaneous detection of two different antigens on paraffin-embedded and frozen tissues can be accomplished by double immunohistochemistry. However, many double chromogen systems suffer from signal overlap, precluding definite signal quantification. To separate and quantitatively analyze the different chromogens, we imported images into a Macintosh computer using a CCD camera attached to a diagnostic microscope and used Photoshop software for the recognition, selection, and separation of colors. We show here that Photoshop-based image analysis allows complete separation of chromogens not only on the basis of their RGB spectral characteristics, but also on the basis of information concerning saturation, hue, and luminosity intrinsic to the digitized images. We demonstrate that Photoshop-based image analysis provides superior results compared to color separation using bandpass filters. Quantification of the individual chromogens is then provided by Photoshop using the Histogram command, which supplies information on the luminosity (corresponding to gray levels of black-and-white images) and on the number of pixels as a measure of spatial distribution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antigen unmasking on formalin‐fixed, paraffin‐embedded tissue sections
Cattoretti, G., Pileri, S., Parravicini, C., Becker, M. H. G., Poggi, S., Bifulco, C., Key, G., D'Amato, L., Sabattini, E., Feudale, E., et al. (1993) · The Journal of Pathology · doi:10.1002/path.1711710205 · Cited by 721 · cited 1×
“Then the sections were treated for antigen retrieval using citrate (10 mM, pH 6.0) in a household microwave oven (Cattoretti et al. 1993): 3 min at 900 W to bring to boiling, 15 min at 250 W to maintain boiling, and 10-min cool-down in the citrate buffer outside the oven.”
MethodInfluentialLehr, H.-A., Mankoff, D. A., Corwin, D., Santeusanio, G., & Gown, A. M. (1997) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215549704501112 · Cited by 308 · cited 3×
“The technique of selection of similar features on a digitized immunohistochemical image has previously been described in detail (Lehr et al. 1997).”
MethodSelf-citationPractical suggestions for successful immunoenzyme double-staining experiments
van der Loos, C. M., Becker, A. E., & van den Oord, J. J. (1993) · The Histochemical Journal · doi:10.1007/bf00161039 · Cited by 108
The use of ?-galactosidase as a tracer in immunocytochemistry
Bondi, A., Chieregatti, G., Eusebi, V., Fulcheri, E., & Bussolati, G. (1982) · Histochemistry and Cell Biology · doi:10.1007/bf00501918 · Cited by 105
C-Type Natriuretic Peptide in Human Coronary Atherosclerotic Lesions
Naruko, T., Ueda, M., van der Wal, A. C., van der Loos, C. M., Itoh, H., Nakao, K., & Becker, A. E. (1996) · Circulation · doi:10.1161/01.cir.94.12.3103 · Cited by 71 · cited 1×
“This color combination can be applied for recognizing two different cell types (van der Wal et al. 1994) and for revealing colocalization by a purple-blue mixed color showing contrast to the basic colors (Naruko et al. 1996; van der Loos et al. 1996).”
Backgroundvan der Wal, A. C., Becker, A. E., van der Loos, C. M., Tigges, A. J., & Das, P. K. (1994) · PubMed · Cited by 56
Optimization of immunofluorescence methods by quantitative image analysis.
Mosedale, D. E., Metcalfe, J. C., & Grainger, D. J. (1996) · Journal of Histochemistry & Cytochemistry · doi:10.1177/44.9.8773570 · Cited by 52 · cited 1×
“124 Lehr, van der Loos, Teeling, Gown et al. 1993), Quantimed 600 (Kohlberger et al. 1996), COSAS (Black and Rosen 1996), MAGICSAN (Mosedale et al. 1996), and NIH image (public domain program; Ruifrok 1997).”
BackgroundBrown, H. E., Garcia, M. M., & Harlan, R. E. (1998) · Brain Research Protocols · doi:10.1016/s1385-299x(98)00003-8 · Cited by 44 · cited 1×
“In contrast to RGB thresholding techniques, which demonstrate improved separation capacities at higher magnifications (Brown et al. 1998), Photoshop-based image analysis uses the color information contained in each individual pixel (color hue, saturation, luminosity) and thus allows separation of…”
ResultThe use of enhanced polymer one-step staining reagents for immunoenzyme double-labelling
van der Loos, C. M., Naruko, T., & Becker, A. E. (1996) · The Histochemical Journal · doi:10.1007/bf02409008 · Cited by 32
Westhuyzen, J., Graham, S. D., Rasiah, R., & Saltissi, D. (1997) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1997.35.1.17 · Cited by 5 · cited 1×
“Several authors have used Photoshop merely as a way of importing scanned images into their computers for later analysis by other programs (Brown et al. 1995; Westhuyzen et al. 1997).”
Method
Cited by
Macrophage Depletion Inhibits Experimental Choroidal Neovascularization
Sakurai, E., Anand, A., Ambati, B. K., van Rooijen, N., & Ambati, J. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0097 · Cited by 503
Peterson, L. M., Mankoff, D. A., Lawton, T., Yagle, K., Schubert, E. K., Stekhova, S., Gown, A., Link, J. M., Tewson, T., & Krohn, K. A. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.047506 · Cited by 251
“In addition, a semiquantitative index of ER staining (IHC index) was calculated by use of a previously described automated image analysis technique and was verified by comparison with a radioligand-bindingassay(Photoshop;AdobeSystems)(28, 29 ).Inbrief, the Photoshop Magic Wand tool was used to identify a representativ…”
MethodSelf-citationLehr, H.-A., Sagban, T. A., Ihling, C., Zähringer, U., Hungerer, K.-D., Blumrich, M., Reifenberg, K., & Bhakdi, S. (2001) · Circulation · doi:10.1161/hc3401.093153 · Cited by 211
Self-citationMCL-1 is a prognostic indicator and drug target in breast cancer
Campbell, K. J., Dhayade, S., Ferrari, N., Sims, A. H., Johnson, E., Mason, S. M., Dickson, A., Ryan, K. M., Kalna, G., Edwards, J., et al. (2018) · Cell Death & Disease · doi:10.1038/s41419-017-0035-2 · Cited by 200
Ramge, P., Unger, R. E., Oltrogge, J. B., Zenker, D., Begley, D., Kreuter, J., & Von Briesen, H. (2000) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2000.00078.x · Cited by 197
Metadata
- Authors
- Lehr, H.-A., van der Loss, C. M., Teeling, P., & Gown, A. M.
- Venue
- Journal of Histochemistry & Cytochemistry
- Publisher
- SAGE Publications
- Published
- 1999-01
- Volume
- 47
- Issue
- 1
- Pages
- 119-125
- ISSN
- 0022-1554 (ISSN-L)
- 1551-5044
- OpenAlex
- W2154098294
- Cited by
- 221
- References
- 10
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.