The Measurement of Energy Expenditure
Abstract
Proper nutrition support depends upon the clinician's ability to estimate the patient's energy expenditure. The accuracy of estimation is inversely proportional to the severity of the patient's illness. This fact has spurred academic and industry groups to pursue the measurement of energy expenditure. Harris and Benedict used indirect calorimetry to develop their now-famous equation nearly 100 years ago. The concept of indirect calorimetry is simple; if you know the concentration of inspired gases and expired gases, along with the flow, you can determine the amount of a gas consumed or produced. The complexity and expense of indirect calorimeters suggest that this simple concept is technically challenging. Because we desire to know the energy expenditure of the most critically ill patients, indirect calorimetry is further confounded by the presence of oxygen and mechanical ventilation. This paper will discuss the myriad of variables and obstacles that complicate the measurement of energy expenditure and will suggest methods to avoid or overcome them.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Energy requirements in polymorbid medical inpatients can be estimated using indirect calorimetry (IC), a published prediction equation or a weight-based formula, although the accuracy of prediction equations in this population is low.”
From ESPEN guideline on nutritional support for polymorbid medical inpatients (2023) · cites this paper as [62]
Citations
Cites
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,688
Measurement of gas exchange in intensive care
Takala, J. A., Keinänen, O., Väisänen, P., & Kari, A. (1989) · Critical Care Medicine · doi:10.1097/00003246-198910000-00015 · Cited by 302
Effect of Routine Intensive Care Interactions on Metabolic Rate
Weissman, C., Kemper, M., Damask, M. C., ASKANAZI, J., Hyman, A. I., & Kinney, J. M. (1984) · CHEST Journal · doi:10.1378/chest.86.6.815 · Cited by 195
Jéquier, E., & Felber, J.-P. (1987) · Baillière's Clinical Endocrinology and Metabolism · doi:10.1016/s0950-351x(87)80011-3 · Cited by 191
Gas Stores of the Body and the Unsteady State
Farhi, L. E., & Rahn, H. (1955) · Journal of Applied Physiology · doi:10.1152/jappl.1955.7.5.472 · Cited by 189
Analysis of error in the determination of respiratory gas exchange at varying FIO2
Ultman, J. S., & Bursztein, S. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.50.1.210 · Cited by 145
Clinical validation of the Deltatrac monitoring system in mechanically ventilated patients
Tissot, S., Delafosse, B. X., Bertrand, O., Bouffard, Y., Viale, J. P., & Annat, G. J. (1995) · Intensive Care Medicine · doi:10.1007/bf01726538 · Cited by 120
A Validation and Comparison Study of Two Metabolic Monitors
Phang, P. T., Rich, T., & Ronco, J. J. (1990) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607190014003259 · Cited by 108
Evaluation of metabolic measuring instruments for use in critically ill patients
Makita, K., NUNN, J. F., & Royston, B. (1990) · Critical Care Medicine · doi:10.1097/00003246-199006000-00013 · Cited by 107
A new handheld device for measuring resting metabolic rate and oxygen consumption
Nieman, D. C., TRONE, G. A., & Austin, M. D. (2003) · Journal of the American Dietetic Association · doi:10.1053/jada.2003.50116 · Cited by 104
Segal, K. R. (1987) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/45.6.1420 · Cited by 99
A Systematic Method for Validation of Gas Exchange Measurements
Damask, M. C., Weissman, C., ASKANAZI, J., Hyman, A. I., Rosenbaum, S. H., & Kinney, J. M. (1982) · Anesthesiology · doi:10.1097/00000542-198209000-00011 · Cited by 99
The effects of a fluctuating Fio2 on metabolic measurements in mechanically ventilated patients
Browning, J. A., Linberg, S. E., Turney, S. Z., & Chodoff, P. (1982) · Critical Care Medicine · doi:10.1097/00003246-198202000-00003 · Cited by 97
Indirect calorimetry in critically Ill patients: Clinical applications and practical advice*1
BRANDI, L. (1997) · Nutrition · doi:10.1016/s0899-9007(97)83059-6 · Cited by 96
Effect of respiratory apparatus on respiration
Weissman, C., ASKANAZI, J., Milic‐Emili, J., & Kinney, J. M. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.57.2.475 · Cited by 94
Meriläinen, P. (1987) · International journal of clinical monitoring and computing · doi:10.1007/bf02915904 · Cited by 89
In vitro evaluation of a compact metabolic measurement instrument
Weissman, C., Sardar, A., & Kemper, M. (1990) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607190014002216 · Cited by 78
Smyrnios, N. A., Curley, F. J., & Shaker, K. G. (1997) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607197021003168 · Cited by 74
Frankenfield, D. C., Sarson, G. Y., Blosser, S. A., Cooney, R. N., & Smith, J. S. (1996) · Journal of the American College of Nutrition · doi:10.1080/07315724.1996.10718615 · Cited by 63
McLellan, S. A., Walsh, T. S., Burdess, A., & Lee, A. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1323-5 · Cited by 63
A New Hand‐Held Indirect Calorimeter to Measure Postprandial Energy Expenditure
St‐Onge, M., Rubiano, F., Jones, A., & Heymsfield, S. B. (2004) · Obesity Research · doi:10.1038/oby.2004.82 · Cited by 62
Errors in Measurement of Oxygen Uptake due to Anesthetic Gases
Aukburg, S. J., Geer, R. T., Wollman, H., & Neufeld, G. R. (1985) · Anesthesiology · doi:10.1097/00000542-198501000-00011 · Cited by 58
Brandi, L. S., Bertolini, R., Santini, L., & Cavani, S. (1999) · Critical Care Medicine · doi:10.1097/00003246-199903000-00030 · Cited by 52
Precision and accuracy in a metabolic monitor for indirect calorimetry
Wells, J. C. K., & Fuller, N. (1998) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600604 · Cited by 52
Petros, S., & Engelmann, L. (2001) · Intensive Care Medicine · doi:10.1007/s001340100941 · Cited by 51
Carbon dioxide production during mechanical ventilation
Henneberg, S. W., Groth, T., Stjernström, H., & Wiklund, L. (1987) · Critical Care Medicine · doi:10.1097/00003246-198701000-00002 · Cited by 50
Oxygen Transport and Utilization
MAIZES, J., MURTUZA, M., & Kvetan, V. (2000) · Respiratory Care Clinics · doi:10.1016/s1078-5337(05)70086-1 · Cited by 48
A Portable Respiration Apparatus for Clinical Use
Benedict, F. G. (1918) · New England Journal of Medicine · doi:10.1056/nejm191805161782003 · Cited by 48
Variation in the Resting Metabolic Rate of Mechanically Ventilated Critically Ill Patients
Weissman, C., Kemper, M., & Hyman, A. I. (1989) · Anesthesia & Analgesia · doi:10.1213/00000539-198904000-00006 · Cited by 47
Monitoring in Respiratory Care
Kacmarek, R. M., Hess, D., & Stoller, J. K. (1993) · Cited by 42
Carbon Dioxide Excretion via Bronchopleural Fistulas in Adult Respiratory Distress Syndrome
Bishop, M. J., Benson, M. S., & Pierson, D. J. (1987) · CHEST Journal · doi:10.1378/chest.91.3.400 · Cited by 40
A new paediatric metabolic monitor
Weyland, W., Weyland, A., Fritz, U., Redecker, K., Ensink, F. B. M., & Braun, U. (1994) · Intensive Care Medicine · doi:10.1007/bf02425058 · Cited by 40
Validation of oxygen consumption measurements during artificial ventilation
NUNN, J. F., Makita, K., & Royston, B. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.5.2129 · Cited by 37
Cunningham, K., Aeberhardt, L. E., Wiggs, B. R., & Phang, P. T. (1994) · The American Journal of Surgery · doi:10.1016/0002-9610(94)90255-0 · Cited by 29
McAnena, O. J., Harvey, L. P., Katzeff, H. L., & DALY, J. M. (1986) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607186010006555 · Cited by 29
Joosten, K. F. M., Verhoeven, J. J., Hop, W. C. J., & HAZELTET, J. (1999) · Clinical Nutrition · doi:10.1016/s0261-5614(99)80004-1 · Cited by 26
MEASUREMENT OF METABOLIC GAS EXCHANGE DURING ANAESTHESIA
HENEGHAN, C. P. H., Gillbe, C. E., & Branthwaite, M. A. (1981) · British Journal of Anaesthesia · doi:10.1093/bja/53.1.73 · Cited by 26
Raurich, J. M., Ibañez, J., & Marsé, P. (1989) · Intensive Care Medicine · doi:10.1007/bf00271067 · Cited by 25
Effects of Gas Leak Around Endotracheal Tubes on Indirect Calorimetry Measurement
Dietrich, K. A., Romero, M. D., & Conrad, S. A. (1990) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607190014004408 · Cited by 24
Metabolic rate in acute respiratory failure complicating sepsis.
Halmagyi, D. F. J., & Jm, K. (1975) · PubMed · Cited by 24
A fast differential paramagnetic O2-sensor
Meriläinen, P. (1988) · International journal of clinical monitoring and computing · doi:10.1007/bf02933716 · Cited by 22
Joosten, K. F. M., Jacobs, F. I. M., van Klaarwater, E., Baartmans, M. G. A., Hop, W. C. J., Meriläinen, P., & Hazelzet, J. A. (2000) · Critical Care Medicine · doi:10.1097/00003246-200008000-00056 · Cited by 21
A miniature rugged and accurate solid electrolyte oxygen sensor
Kocache, R. M., Swan, J., & Holman, D. F. (1984) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/17/6/014 · Cited by 20
In vitro validation of a metabolic monitor for gas exchange measurements in ventilated neonates
Behrends, M., Kernbach, M., Bräuer, A., Braun, U., Peters, J., & Weyland, W. (2000) · Intensive Care Medicine · doi:10.1007/s001340000708 · Cited by 19
Evaluation of a Non-Invasive Method for the Measurement of Metabolic rate in Humans
Weissman, C., Damask, M. C., ASKANAZI, J., Rosenbaum, S. H., & Kinney, J. M. (1985) · Clinical Science · doi:10.1042/cs0690135 · Cited by 17
Evaluation of methods for indirect calorimetry with a ventilated lung model
Braun, U., Zundel, J., Freiboth, K., Weyland, W., Turner, E. L., Heidelmeyer, C. F., & Hellige, G. (1989) · Intensive Care Medicine · doi:10.1007/bf01058573 · Cited by 16
González-Arévalo, A., Gómez-Arnau, J. I., delaCruz, J., Lacoma, F. J., Galdós, P., & del Valle, S. G. (2003) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000087881.42502.2d · Cited by 11
Behrendt, W., Surmann, M., Raumanns, J., & Giani, G. (1991) · Transfusion Medicine and Hemotherapy · doi:10.1159/000222690 · Cited by 9
Indirect calorimetry in patients with active respiratory infection — prevention of cross-infection
Schwenk, A., MERILOINEN, P., & Macallan, D. C. (2002) · Clinical Nutrition · doi:10.1054/clnu.2002.0562 · Cited by 7
Evaluations of the Waters MRM-6000 and Biergy VVR Closed-Circuit Indirect Calorimeters
Keppler, T., Dechert, R. E., Arnoldi, D. K., Filius, R., & Bartlett, R. H. (1989) · Respiratory Care · doi:10.1177/194336548903400105 · Cited by 5
A simple technique to reduce ventilator-dependent errors in oxygen consumption measurements.
Dickerson, R. N., Murrell, J. E., Brown, R. O., Kudsk, K. A., & Leeper, K. V. (1995) · PubMed · Cited by 5
van Lanschot, J. J. B. (1987) · Cited by 4
Isolation Valve Increases Work of Breathing in a Mechanically Ventilated Pediatric Animal Model
Fiser, R. T., Torres, A., Holt, S., Wilson, S., & Heulitt, M. J. (1997) · Respiratory Care · doi:10.1177/002013249704200703 · Cited by 3
Technical aspects of metabolic measurements.
Branson, R. D. (1995) · PubMed · Cited by 3
Self-citation(1990) · Clinical Nutrition · doi:10.1016/0261-5614(90)90225-h · Cited by 2
Research works printed but not linked: 11
- Harris JA, 1919, Standard Basal Metabolism Constants for Physiologists and Clinicians: A Biometric Study of Basal Metabolism in Man, 223
- Halmagyi DFJ, 1975, Metabolic rate in active respiratoryfailure complicating sepsis, Surgery., 77, 492
- Norton AC, 1979, Accuracy in pulmonary measurement, Respir Care., 24, 131
- Branson RD, 1990, The measurement of energy expenditure: instrumentation, practical considerations and clinical application, Respir Care., 35, 640
- Branson RD, 1992, A simple method for stabilizinginspired oxygen concentration during metabolic measurements [abstract], JPEN J Parenter Enteral Nutr, 16, 33S
- Dickerson RN, 1995, Asimple technique to reduce ventilator dependent errors in oxygen consumptionmeasurements, Nutrition, 11, 145
- Head CA, 1985, A valvesystem for the accurate measurement of energy expenditure in mechanicallyventilated patients, Respir Care., 30, 969
- Kemper MS, 1989, Problems in Respiratory Care: Nutrition and Respiratory Disease, 479
- Fiser RT, 1997, Isolation valveincreases work of breathing in a mechanically ventilated pediatric animalmodel, Respir Care., 42, 688
- Branson RD, 1988, A laboratoryevaluation of the Biergy VVR calorimeter, Respir Care., 33, 341
- Cunnigham KF, 1994, Appropriateinterpretation of indirect calorimetry for determining energy expenditure inintensive care units, Am J Surg., 167, 54
Cited by
Sorted by citations
ESPEN guidelines on nutritional support for polymorbid internal medicine patients
Gomes, F., Schuetz, P., Bounoure, L., Austin, P., Ballesteros-Pomar, M., Cederholm, T., Fletcher, J., Laviano, A., Norman, K., Poulia, K.-A., et al. (2018) · Clinical Nutrition · doi:10.1016/j.clnu.2017.06.025 · Cited by 363
Indirect calorimetry: methodology, instruments and clinical application
da Rocha, E. E. M., Alves, V. G. F., & da Fonseca, R. B. V. (2006) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/01.mco.0000222107.15548.f5 · Cited by 177
Indirect Calorimetry: History, Technology, and Application
Mtaweh, H., Tuira, L., Floh, A. A., & Parshuram, C. S. (2018) · Frontiers in Pediatrics · doi:10.3389/fped.2018.00257 · Cited by 171
Autonomic Contribution to Blood Pressure and Metabolism in Obesity
Shibao, C., Gamboa, A., Diedrich, A., Ertl, A. C., Chen, K. Y., Byrne, D. W., Farley, G., Paranjape, S. Y., Davis, S. N., & Biaggioni, I. (2007) · Hypertension · doi:10.1161/01.hyp.0000251679.87348.05 · Cited by 147
Stapel, S. N., de Grooth, H.-J. S., Alimohamad, H., Elbers, P. W. G., Girbes, A. R. J., Weijs, P. J. M., & Oudemans-van Straaten, H. M. (2015) · Critical Care · doi:10.1186/s13054-015-1087-2 · Cited by 118
Metadata
- Authors
- Branson, R. D., & Johannigman, J. A.
- Affiliations
- University of Cincinnati (US)
- Corresponding author
- Branson, Richard D.
- ORCID
- Branson, Richard D.
- Venue
- Nutrition in Clinical Practice
- Publisher
- Wiley
- Published
- 2004-12
- Volume
- 19
- Issue
- 6
- Pages
- 622-636
- ISSN
- 0884-5336 (ISSN-L)
- 1941-2452
- OpenAlex
- W2033421301
- Cited by
- 111
- References
- 56
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 3 · 2023: 13 · 2022: 4 · 2021: 5 · 2020: 7 · 2019: 8 · 2018: 6 · 2017: 9 · 2016: 5 · 2015: 6 · 2014: 2 · 2013: 7 · 2012: 3
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Nutrition in Clinical Practice (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Nursing › Nutrition and Dietetics › Clinical Nutrition and Gastroenterology
- Health Sciences › Medicine › Physiology (medical) › Biomedical and Chemical Research
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Keywords
- energy expenditure, indirect calorimetry, Harris-Benedict equation, critically ill patients, mechanical ventilation, oxygen consumption, nutritional support
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review