Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 209

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Bioimpedance Spectroscopy for Clinical Assessment of Fluid Distribution and Body Cell Mass

Earthman, Carrie, Traughber, Diana, Dobratz, Jennifer, Howell, Wanda·2007·Nutrition in Clinical Practice

Abstract

Body composition assessment has been used to evaluate clinical interventions in research trials, and has the potential to improve patient care in the clinical setting. Body cell mass (BCM) is an important indicator of nutrition status; however, its measurement in the clinic has been limited. BCM can be estimated by the measurement of intracellular water (ICW). The assessment of extracellular water (ECW) is also important because many clinical populations undergo alterations in fluid distribution, particularly individuals with wasting, those receiving dialysis, and obese individuals. Bioimpedance spectroscopy (BIS) is a unique bioimpedance approach that differs in underlying basis from the more readily recognized single‐frequency bioelectrical impedance analysis (SF‐BIA) in that it does not require the use of statistically derived, population‐specific prediction equations. It has the potential advantage of not only measuring total body water (TBW), as does SF‐BIA, but also offering the unique capacity to differentiate between ECW and ICW and, thus, to provide an estimate of BCM. This literature review was conducted to compare available BIS devices to multiple dilution for measuring fluid compartments or BCM in a number of populations. Variable results regarding the ability of BIS to measure absolute volumes, as well as the observation of wide limits of variation, make BIS problematic for individual assessment in the clinic, particularly in populations with abnormal fluid distribution or body geometry. BIS has been found to be more accurate for measuring changes in fluid volumes or BCM, particularly in post‐surgical and human immunodeficiency virus (HIV)‐infected individuals. It is certainly possible that population‐specific adjustments may improve the accuracy of BIS for assessing individuals in the clinical setting; however, additional research and development is needed before the method can be accepted for routine clinical use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0115426507022004389

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 209

Metadata

Authors
Earthman, C., Traughber, D., Dobratz, J., & Howell, W.
Venue
Nutrition in Clinical Practice
Publisher
Wiley
Published
2007-08
Volume
22
Issue
4
Pages
389-405
ISSN
  • 0884-5336 (ISSN-L)
  • 1941-2452
OpenAlex
W2165093441
Cited by
209
References
3
FWCI
3.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bioimpedance Spectroscopy for Clinical Assessment of Fluid Distribution and Body Cell Mass. https://app.cochat.ai/papers/10.1177/0115426507022004389
The paper
Earthman, C., Traughber, D., Dobratz, J., & Howell, W. (2007). Bioimpedance Spectroscopy for Clinical Assessment of Fluid Distribution and Body Cell Mass. Nutrition in Clinical Practice. https://doi.org/10.1177/0115426507022004389

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.