Bioimpedance Spectroscopy for Clinical Assessment of Fluid Distribution and Body Cell Mass
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Body composition assessment has been used to evaluate clinical interventions in research trials, and has the potential to improve patient care in the clinical setting. Body cell mass (BCM) is an important indicator of nutrition status; however, its measurement in the clinic has been limited. BCM can be estimated by the measurement of intracellular water (ICW). The assessment of extracellular water (ECW) is also important because many clinical populations undergo alterations in fluid distribution, particularly individuals with wasting, those receiving dialysis, and obese individuals. Bioimpedance spectroscopy (BIS) is a unique bioimpedance approach that differs in underlying basis from the more readily recognized single‐frequency bioelectrical impedance analysis (SF‐BIA) in that it does not require the use of statistically derived, population‐specific prediction equations. It has the potential advantage of not only measuring total body water (TBW), as does SF‐BIA, but also offering the unique capacity to differentiate between ECW and ICW and, thus, to provide an estimate of BCM. This literature review was conducted to compare available BIS devices to multiple dilution for measuring fluid compartments or BCM in a number of populations. Variable results regarding the ability of BIS to measure absolute volumes, as well as the observation of wide limits of variation, make BIS problematic for individual assessment in the clinic, particularly in populations with abnormal fluid distribution or body geometry. BIS has been found to be more accurate for measuring changes in fluid volumes or BCM, particularly in post‐surgical and human immunodeficiency virus (HIV)‐infected individuals. It is certainly possible that population‐specific adjustments may improve the accuracy of BIS for assessing individuals in the clinical setting; however, additional research and development is needed before the method can be accepted for routine clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1998) · PsycEXTRA Dataset · doi:10.1037/e565682010-001 · Cited by 9,472
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Magnitude of body-cell-mass depletion and the timing of death from wasting in AIDS
Kotler, D. P., Tierney, A. R., Wang, J., & Pierson, R. N. (1989) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/50.3.444 · Cited by 793
Predicting body cell mass with bioimpedance by using theoretical methods: a technological review
De Lorenzo, A., Andreoli, A., Matthie, J., & Withers, P. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.5.1542 · Cited by 654
Body fluid volume determination via body composition spectroscopy in health and disease
Moissl, U. M., Wabel, P., Chamney, P. W., Bosaeus, I., Levin, N. W., Bosy-Westphal, A., Korth, O., Müller, M. J., Ellegård, L., Malmros, V., et al. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/9/012 · Cited by 608
Forbes, G. B. (1987) · doi:10.1007/978-1-4612-4654-1 · Cited by 431
PERMEABILITY AND IMPERMEABILITY OF CELL MEMBRANES FOR IONS
Cole, K. S. (1940) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.1940.008.01.013 · Cited by 418
Effect of obesity on bioelectrical impedance
Gray, D. S., Bray, G. A., Gemayel, N., & Kaplan, K. (1989) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/50.2.255 · Cited by 291
Cited by
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
“stated that the trunk represents 50% of the body mass [55].”
BackgroundMarra, M., Sammarco, R., De Lorenzo, A., Iellamo, F., Siervo, M., Pietrobelli, A., Donini, L. M., Santarpia, L., Cataldi, M., Pasanisi, F., et al. (2019) · Contrast Media & Molecular Imaging · doi:10.1155/2019/3548284 · Cited by 401
“BIS has been found to be accurate for measuring changes in fluid volumes [26].”
MethodBioimpedance at the Bedside: Current Applications, Limitations, and Opportunities
Mulasi, U., Kuchnia, A. J., Cole, A. J., & Earthman, C. P. (2015) · Nutrition in Clinical Practice · doi:10.1177/0884533614568155 · Cited by 337
Self-citationLukaski, H. C. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.149 · Cited by 303
Earthman, C. P. (2015) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115595227 · Cited by 234
“As such, the BCM has been considered by many to be the primary lean tissue compartment to assess nutrition status and to serve as a key target for nutrition interventions.(32,33) There is no direct way to quantify BCM, but there are several ways it can be estimated, including from total body nitrogen determined by neu…”
BackgroundSelf-citationNaranjo-Hernández, D., Reina-Tosina, J., & Min, M. (2019) · Journal of Sensors · doi:10.1155/2019/9210258 · Cited by 193
“The bioimpedance methods also have many practical advantages that have guided its rapid development [152, 153]: the instrumentation is portable, relatively lowcost, and the measurements can be carried out quickly with minimal operator training; bioimpedance methods require little maintenance and the measurements are s…”
BackgroundKyle, U. G., Earthman, C. P., Pichard, C., & Coss-Bu, J. A. (2015) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2015.86 · Cited by 183
Self-citationParry, S. M., Granger, C. L., Berney, S., Jones, J., Beach, L., El-Ansary, D., Koopman, R., & Denehy, L. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3672-x · Cited by 183
Resting energy expenditure and body composition in patients with newly detected cancer
Cao, D.-X., Wu, G.-H., Zhang, B., Quan, Y.-J., Wei, J., Jin, H., Jiang, Y., & Yang, Z.-A. (2010) · Clinical Nutrition · doi:10.1016/j.clnu.2009.07.001 · Cited by 174
“Some studies described BIA as an unreliable measure of body composition assessment in cancer patients with ascites.(38,39) However, the result of this study can be regarded reliable since none of the subjects presented with visible ascites, and common influential factors have been avoided by the application of exclusi…”
Teigen, L. M., Kuchnia, A. J., Mourtzakis, M., & Earthman, C. P. (2017) · Nutrition in Clinical Practice · doi:10.1177/0884533616676264 · Cited by 75
Self-citationAssessment of body cell mass at bedside in critically ill patients
Savalle, M., Gillaizeau, F., Maruani, G., Puymirat, E., Bellenfant, F., Houillier, P., Fagon, J.-Y., & Faisy, C. (2012) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00502.2011 · Cited by 60
“Few authors have investigated BCM in ICU, predominantly in surgical patients and by using specific population regression models derived from BIA measurements with inconsistent precision (9, 19).”
MethodBecroft, L., Ooi, G., Forsyth, A., King, S., & Tierney, A. (2019) · International Journal of Obesity · doi:10.1038/s41366-018-0285-9 · Cited by 51
Parry, S. M., Berney, S., Koopman, R., Bryant, A., El-Ansary, D., Puthucheary, Z., Hart, N., Warrillow, S., & Denehy, L. (2012) · BMJ Open · doi:10.1136/bmjopen-2012-001891 · Cited by 50
Tinsley, G. M. (2021) · British Journal of Nutrition · doi:10.1017/s0007114520003578 · Cited by 29
Metadata
- Authors
- Earthman, C., Traughber, D., Dobratz, J., & Howell, W.
- Venue
- Nutrition in Clinical Practice
- Publisher
- Wiley
- Published
- 2007-08
- Volume
- 22
- Issue
- 4
- Pages
- 389-405
- ISSN
- 0884-5336 (ISSN-L)
- 1941-2452
- OpenAlex
- W2165093441
- Cited by
- 209
- References
- 50
- FWCI
- 3.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.