CoChat

Day‐to‐Day Variance in Measurement of Resting Metabolic Rate Using Ventilated‐Hood and Mouthpiece & Nose‐Clip Indirect Calorimetry Systems

Roffey, Darren M., Byrne, Nuala M., Hills, Andrew P. · 2006 · Journal of Parenteral and Enteral Nutrition
Cited by 76

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: To know if the magnitude of change in resting metabolic rate (RMR) observed during an intervention is meaningful, it is imperative to first identify the variability that occurs within individuals from day to day under normal conditions. The 2 most common systems used to measure RMR involve a ventilated hood or a mouthpiece & nose clip to collect expired gases. The variation in measurement using these 2 approaches has not been systematically compared. Methods: RMR was measured in 10 healthy adults during 5 separate testing sessions within a 2‐week period where usual diet and physical activity were maintained. Each testing session consisted of one measurement of RMR using a ventilated hood system, followed by another using a mouthpiece & nose‐clip system. Results: No significant difference in RMR was evident between measurement sessions using either indirect calorimeter. Oxygen consumption and RMR were significantly higher using the mouthpiece & nose‐clip system. Average within‐individual coefficient of variation for RMR was significantly lower for the ventilated‐hood system. RMR measures were consistently lower using the ventilated‐hood system by an average of 94.5 ± 63.3 kcal. Day‐to‐day variance was between 2% and 4% for both systems. Conclusions: The use of either system is appropriate for assessing RMR in clinical and research settings, but alternating between systems should be undertaken with caution. A change in RMR must be greater than ∼6% (96 kcal/d; 1.2 kcal/kg/d) or∼ 8% (135 kcal/d; 1.7 kcal/kg/d) when using a ventilated‐hood system or a mouthpiece & nose‐clip system, respectively, to observe any meaningful intervention‐related differences within individuals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0148607106030005426

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 76

Metadata

Authors
Roffey, D. M., Byrne, N. M., & Hills, A. P.
Venue
Journal of Parenteral and Enteral Nutrition
Publisher
Wiley
Published
2006-09
Volume
30
Issue
5
Pages
426-432
ISSN
  • 0148-6071 (ISSN-L)
  • 1941-2444
OpenAlex
W1506591487
Cited by
76
References
1
FWCI
1.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Day‐to‐Day Variance in Measurement of Resting Metabolic Rate Using Ventilated‐Hood and Mouthpiece & Nose‐Clip Indirect Calorimetry Systems. https://app.cochat.ai/papers/10.1177/0148607106030005426
The paper
Roffey, D. M., Byrne, N. M., & Hills, A. P. (2006). Day‐to‐Day Variance in Measurement of Resting Metabolic Rate Using Ventilated‐Hood and Mouthpiece & Nose‐Clip Indirect Calorimetry Systems. Journal of Parenteral and Enteral Nutrition. https://doi.org/10.1177/0148607106030005426

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.