CoChat

A Computerized Insulin Infusion Titration Protocol Improves Glucose Control With Less Hypoglycemia Compared to a Manual Titration Protocol in a Trauma Intensive Care Unit

Dortch, Marcus J., Mowery, Nathan T., Ozdas, Asli, Dossett, Lesly, Cao, Hanqing, Collier, Bryan, Holder, Gwen, Miller, Randolph A., May, Addison K. · 2008 · Journal of Parenteral and Enteral Nutrition
Cited by 83

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Previous studies reflect reduced morbidity and mortality with intensive blood glucose control in critically ill patients. Unfortunately, implementation of such protocols has proved challenging. This study evaluated the degree of glucose control using manual paper‐based vs computer‐based insulin protocols in a trauma intensive care unit. Methods: Of 1455 trauma admissions from May 31 to December 31, 2005, a cohort of 552 critically ill patients met study entry criteria. The patients received intensive blood glucose management with IV insulin infusions. Using Fisher's exact test, the authors compared patients managed with a computerized protocol vs a paper‐based insulin protocol with respect to the portion of glucose values in a target range of 80–110 mg/dL, the incidence of hyperglycemia (≥150 mg/dL), and the incidence of hypoglycemia (≤40 mg/dL). Results: Three hundred nine patients were managed with a manual paper‐based protocol and 243 were managed with a computerized protocol. The total number of blood glucose values across both groups was 21,178. Mean admission glucose was higher in the computer‐based protocol group (170 vs 152 mg/dL; p < .001, t‐test). Despite this finding by Fisher's exact test, glucose control was superior in the computerized group; a higher portion of glucose values was in range 80–110 mg/dL (41.8% vs 34.0%; p < .001), less hyperglycemia occurred (12.8% vs 15.1%; p < .001), and less hypoglycemia occurred (0.2% vs 0.5%; p < .001). Conclusions: A computerized insulin titration protocol improves glucose control by (1) increasing the percentage of glucose values in range, (2) reducing hyperglycemia, and (3) reducing severe hypoglycemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/014860710803200118

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 22

  1. 10.1016/0026-0495(79)90066-0 · DOI · Paper page
  2. 10.1111/j.1445-5994.1987.tb00098.x · doi:10.1111/j.1445-5994.1987.tb00098.x
  3. 10.1042/cs0900189 · DOI
  4. 10.1177/0148607105029005353 · DOI
  5. 10.1056/NEJMoa011300 · DOI · Paper page
  6. 10.1086/501830 · DOI · Paper page
  7. 10.1097/01.CCM.0000117317.18092.E4 · DOI · Paper page
  8. 10.1197/jamia.M2292 · DOI
  9. 10.7326/0003-4819-97-2-210 · DOI · Paper page
  10. 10.1097/00005373-198704000-00005 · DOI · Paper page
  11. 10.1592/phco.26.2.214 · DOI
  12. 10.1089/dia.2006.8.476 · DOI
  13. 10.1097/00003246-200109000-00010 · DOI
  14. 10.1053/j.jvca.2004.08.003 · DOI
  15. 10.2337/diacare.27.2.461 · DOI · Paper page
  16. 10.1007/s00134-004-2252-2 · DOI · Paper page
  17. 10.4065/79.8.992 · DOI · Paper page
  18. 10.1016/j.jamcollsurg.2005.09.015 · DOI
  19. 10.1345/aph.1E018 · DOI · Paper page
  20. 10.2337/diacare.28.10.2418 · DOI · Paper page
  21. 10.1186/1472-6947-5-38 · DOI · Paper page
  22. 10.1197/jamia.M1598 · DOI · Paper page

Cited by

See all 83

Metadata

Authors
Dortch, M. J., Mowery, N. T., Ozdas, A., Dossett, L., Cao, H., Collier, B., Holder, G., Miller, R. A., & May, A. K.
Venue
Journal of Parenteral and Enteral Nutrition
Publisher
Wiley
Published
2008-01
Volume
32
Issue
1
Pages
18-27
ISSN
  • 0148-6071 (ISSN-L)
  • 1941-2444
OpenAlex
W1967071559
Cited by
83
References
2
FWCI
8.71
Type
journal article
Language
en
Open access
closed
Funders
National Institutes of Health (1‐R01‐LM007995)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Computerized Insulin Infusion Titration Protocol Improves Glucose Control With Less Hypoglycemia Compared to a Manual Titration Protocol in a Trauma Intensive Care Unit. https://app.cochat.ai/papers/10.1177/014860710803200118
The paper
Dortch, M. J., Mowery, N. T., Ozdas, A., Dossett, L., Cao, H., Collier, B., Holder, G., Miller, R. A., & May, A. K. (2008). A Computerized Insulin Infusion Titration Protocol Improves Glucose Control With Less Hypoglycemia Compared to a Manual Titration Protocol in a Trauma Intensive Care Unit. Journal of Parenteral and Enteral Nutrition. https://doi.org/10.1177/014860710803200118

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.