A Validation and Comparison Study of Two Metabolic Monitors
The DOI matches its Crossref record.
Abstract
Two portable metabolic cart systems of indirect calorimetry (Deltatrac Metabolic Monitor, 2900 MMC System) were validated. CO 2 and N 2 were delivered at precise rates into a constructed lung model to simulate CO 2 production (VCO 2) and O 2 consumption (VO 2). VCO 2 (200–400 ml/min) and VO 2 (250–750 ml/min) were measured at varying combinations of minute ventilation (VE) (6, 10, 20 liter/min) and FiO 2 (0.21, 0.30, 0.60, 0.80). VCO 2 was measured with overall errors of 1.5% and 2.4% for the Deltatrac and 2900 monitors, respectively. VO 2 was measured with overall errors of 1.9% and 3.2% by the Deltatrac and 2900 monitors, respectively. Both monitors performed equally well for measurement of VO 2 at FiO 2 up to 0.6, but the Deltatrac had less error for measurements of VO 2 at FiO 2 of 0.8. (Journal of Parenteral and Enteral Nutrition 14:259–261, 1990)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Frankenfield, D., Roth-Yousey, L., & Compher, C. (2005) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2005.02.005 · Cited by 623
Indirect calorimetry in nutritional therapy. A position paper by the ICALIC study group
Oshima, T., Berger, M. M., De Waele, E., Guttormsen, A. B., Heidegger, C.-P., Hiesmayr, M., Singer, P., Wernerman, J., & Pichard, C. (2017) · Clinical Nutrition · doi:10.1016/j.clnu.2016.06.010 · Cited by 283
“However, the use of the Haldane transformation formula introduces a mathematical limitation, especially in case of O2 enrichment higher than 60% as the inaccuracy of the analyzers will be enhanced by the calculation [28,30,34].”
MethodVariability in energy expenditure and its components
Donahoo, W. T., Levine, J. A., & Melanson, E. L. (2004) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/00075197-200411000-00003 · Cited by 236
Ronco, J. J., Phang, P. T., Walley, K. R., Wiggs, B., Fenwick, J. C., & Russell, J. A. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.6.1267 · Cited by 191
Self-citationRonco, J. J., Fenwick, J. C., Wiggs, B. R., Phang, P. T., Russell, J. A., & Tweeddale, M. G. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.1.25 · Cited by 176
Self-citationThe metabolic effects of thermal injury
Tredget, E. E., & Yu, Y. M. (1992) · World Journal of Surgery · doi:10.1007/bf02067117 · Cited by 149
The Measurement of Energy Expenditure
Branson, R. D., & Johannigman, J. A. (2004) · Nutrition in Clinical Practice · doi:10.1177/0115426504019006622 · Cited by 111
Metadata
- Authors
- Phang, P. T., Rich, T., & Ronco, J.
- Venue
- Journal of Parenteral and Enteral Nutrition
- Publisher
- Wiley
- Published
- 1990-05
- Volume
- 14
- Issue
- 3
- Pages
- 259-261
- ISSN
- 0148-6071 (ISSN-L)
- 1941-2444
- OpenAlex
- W2033302228
- Cited by
- 106
- References
- 0
- FWCI
- 5.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.