Methods for Estimation of Subsample Time Delays of Digitized Echo Signals
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Time delay estimation (TDE) is commonly performed in practice by crosscorrelation of digitized echo signals. Since time delays are generally not integral multiples of the sampling period, the location of the largest sample of the crosscorrelation function (ccf) is an inexact estimator of the location of the peak. Therefore, one must interpolate between the samples of the ccf to improve the estimation precision. Using theory and simulations, we review and compare the performance of several methods for interpolation of the ccf. The maximum likelihood approach to interpolation is the application of a reconstruction filter to the discrete ccf. However, this method can only be approximated in practice and can be computationally intensive. For these reasons, a simple method is widely used that involves fitting a parabola (or other curve) to samples of the ccf in the neighborhood of its peak. We describe and compare two curve-fitting methods: parabolic and cosine interpolation. Curve-fitting interpolation can yield biased time-delay estimates, which may preclude the use of these methods in some applications. The artifactual effect of these bias errors on elasticity imaging by elastography is discussed. We demonstrate that reconstructive interpolation is unbiased. An iterative implementation of the reconstruction procedure is proposed that can reduce the Computation time significantly.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The generalized correlation method for estimation of time delay
Knapp, C., & Carter, G. (1976) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1976.1162830 · Cited by 4,433
Detection, Estimation, and Modulation Theory, Part I
Van Trees, H. L. (2001) · John Wiley & Sons, Inc. eBooks · doi:10.1002/0471221082 · Cited by 3,891
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Self-citationCoherence and time delay estimation
Carter, G. C. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13723 · Cited by 1,200
A digital signal processing approach to interpolation
Schafer, R. W., & Rabiner, L. R. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.9150 · Cited by 554
Algorithms for ambiguity function processing
Stein, S. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163621 · Cited by 496
Flax, S. W., & O’Donnell, M. (1988) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.9333 · Cited by 483
(1993) · NDT & E International · doi:10.1016/0963-8695(93)90667-j · Cited by 395
An overview on the time delay estimate in active and passive systems for target localization
Quazi, A. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163618 · Cited by 393
Angle Independent Ultrasonic Detection of Blood Flow
Trahey, G. E., Allison, J. W., & von Ramm, O. T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325938 · Cited by 386
Flow velocity profile via time-domain correlation: error analysis and computer simulation
Foster, S. G., Embree, P. M., & O'Brien, W. D. (1990) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.55306 · Cited by 227
Fundamental limitations in passive time-delay estimation--Part II: Wide-band systems
Weinstein, E., & Weiss, A. (1984) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1984.1164429 · Cited by 222
Reduction of Image Noise in Elastography
Céspedes, I., & Ophir, J. (1993) · Ultrasonic Imaging · doi:10.1177/016173469301500202 · Cited by 199
Self-citationOptimum Passive Bearing Estimation in a Spatially Incoherent Noise Environment
MacDonald, V. H., & Schultheiss, P. M. (1969) · The Journal of the Acoustical Society of America · doi:10.1121/1.1911659 · Cited by 190
Measurement of soft tissue motion using correlation between A-scans
Dickinson, R. J., & Hill, C. R. (1982) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(82)90032-1 · Cited by 186
de Jong, P. G. M., Arts, T. G. J., Hoeks, A. P. G., & Reneman, R. S. (1990) · Ultrasonic Imaging · doi:10.1177/016173469001200202 · Cited by 141
Walker, W. F., & Trahey, G. E. (1994) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.308499 · Cited by 113
Analysis of discrete implementation of generalized cross correlator
Boucher, R., & Hassab, J. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163623 · Cited by 111
Ultrasonic study of in vivo kinetic characteristics of human tissues
Tristam, M., Barbosa, D. C., Cosgrove, D. O., Nassiri, D. K., Bamber, J. C., & Hill, C. R. (1986) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(86)90061-x · Cited by 83
Measurements of ultrasonic pulse arrival time differences produced by abdominal wall specimens
Sumino, Y., & Waag, R. C. (1991) · The Journal of the Acoustical Society of America · doi:10.1121/1.401766 · Cited by 74
DEJONG, P., Arts, T. G. J., Hoeks, A. P. G., & Reneman, R. S. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90081-r · Cited by 54
Devasahayam, S. R. (2012) · Springer eBooks · doi:10.1007/978-1-4614-5332-1_6 · Cited by 43
Exact maximum likelihood time delay estimation for short observation intervals
Champagne, B., Eizenman, M., & Pasupathy, S. (1991) · IEEE Transactions on Signal Processing · doi:10.1109/78.136531 · Cited by 35
de Jong, P. G. M., Arts, T. G. J., Hoeks, A. P. G., et al. (1991) · Ultrasonic Imaging · doi:10.1177/016173469101300203 · Cited by 35
Lower bounds on worst case probability of large error for two channel time delay estimation
Ianniello, J. P. (1985) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1985.1164703 · Cited by 23
A small volume thermodynamic system for B/A measurement
Zhang, J., & Dunn, F. E. (1991) · The Journal of the Acoustical Society of America · doi:10.1121/1.400370 · Cited by 18
Diffraction correction methods for pulse-echo acoustic attenuation estimation
Céspedes, I., & Ophir, J. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90104-k · Cited by 16
Self-citationDelay estimation simulations and a normalized comparison of published results
Kirlin, R. L., & Bradley, J. N. (1982) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1982.1163895 · Cited by 16
A note on strain estimation using correlation techniques [tissue]
Kallel, F., & Bertrand, M. (1993) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1993.339664 · Cited by 8
Research works printed but not linked: 3
- Bendat J.S., 1986, Random Data: Analysis and Measurement
- Céspedes I., Elastography: Imaging of Biological Tissue Elasticity, Ph.D. Dissertation (Dept. of Electrical Engineering, University of Houston, Texas, 1993).
- Trahey G.E., 1988, IEEE Trans. Biomed. Eng., 34, 965
Cited by
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Self-citationA Least-Squares Strain Estimator for Elastography
Kallel, F., & Ophir, J. (1997) · Ultrasonic Imaging · doi:10.1177/016173469701900303 · Cited by 432
Self-citationA fast normalized cross-correlation calculation method for motion estimation
Luo, J., & Konofagou, E. E. (2010) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1554 · Cited by 384
Direct Localization for Massive MIMO
Garcia, N., Wymeersch, H., Larsson, E. G., Haimovich, A. M., & Coulon, M. (2017) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2017.2666779 · Cited by 379
Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation
Lubinski, M. A., Emelianov, S. Y., & O'Donnell, M. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.741427 · Cited by 379
Metadata
- Authors
- Céspedes, I., Huang, Y., Ophir, J., & Spratt, S.
- Affiliations
- The University of Texas Medical School Radiology Department - Ultrasonics Laboratory Houston, TX 77030
- Diasonics Ultrasound Inc. San Jose, CA
- ORCID
- Céspedes, I.
- Venue
- Ultrasonic Imaging
- Publisher
- SAGE Publications
- Published
- 1995-04
- Volume
- 17
- Issue
- 2
- Pages
- 142-171
- ISSN
- 0161-7346 (ISSN-L)
- 1096-0910
- OpenAlex
- W2044310882
- Cited by
- 436
- References
- 28
- Citations by year
- 2026: 10 · 2025: 15 · 2024: 11 · 2023: 21 · 2022: 16 · 2021: 17 · 2020: 19 · 2019: 25 · 2018: 22 · 2017: 18 · 2016: 10 · 2015: 20 · 2014: 21 · 2013: 17 · 2012: 16
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Ultrasonic Imaging (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca038515-07, 5r01ca060520-03)
- National Cancer Institute (R01-CA60520, P01-CA64579, R01-CA-38515)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Physical Sciences › Earth and Planetary Sciences › Oceanography › Underwater Acoustics Research
- Keywords
- time delay estimation, echo signal, cross correlation function, interpolation, parabolic interpolation, curve fitting, reconstruction filter, maximum likelihood estimation, bias, elastography, iterative reconstruction
- MeSH terms
- Computer Simulation, Humans, Image Processing, Computer-Assisted, Signal Processing, Computer-Assisted, Time Factors, Ultrasonography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.