Methods for Estimation of Subsample Time Delays of Digitized Echo Signals
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Time delay estimation (TDE) is commonly performed in practice by crosscorrelation of digitized echo signals. Since time delays are generally not integral multiples of the sampling period, the location of the largest sample of the crosscorrelation function (ccf) is an inexact estimator of the location of the peak. Therefore, one must interpolate between the samples of the ccf to improve the estimation precision. Using theory and simulations, we review and compare the performance of several methods for interpolation of the ccf. The maximum likelihood approach to interpolation is the application of a reconstruction filter to the discrete ccf. However, this method can only be approximated in practice and can be computationally intensive. For these reasons, a simple method is widely used that involves fitting a parabola (or other curve) to samples of the ccf in the neighborhood of its peak. We describe and compare two curve-fitting methods: parabolic and cosine interpolation. Curve-fitting interpolation can yield biased time-delay estimates, which may preclude the use of these methods in some applications. The artifactual effect of these bias errors on elasticity imaging by elastography is discussed. We demonstrate that reconstructive interpolation is unbiased. An iterative implementation of the reconstruction procedure is proposed that can reduce the Computation time significantly.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The generalized correlation method for estimation of time delay
Knapp, C., & Carter, G. (1976) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1976.1162830 · Cited by 4,433
Detection, Estimation, and Modulation Theory, Part I
Van Trees, H. L. (2001) · John Wiley & Sons, Inc. eBooks · doi:10.1002/0471221082 · Cited by 3,891
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Self-citationCoherence and time delay estimation
Carter, G. C. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13723 · Cited by 1,200
A digital signal processing approach to interpolation
Schafer, R. W., & Rabiner, L. R. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.9150 · Cited by 554
Algorithms for ambiguity function processing
Stein, S. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163621 · Cited by 496
Flax, S. W., & O’Donnell, M. (1988) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.9333 · Cited by 483
(1993) · NDT & E International · doi:10.1016/0963-8695(93)90667-j · Cited by 395
An overview on the time delay estimate in active and passive systems for target localization
Quazi, A. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163618 · Cited by 393
Angle Independent Ultrasonic Detection of Blood Flow
Trahey, G. E., Allison, J. W., & von Ramm, O. T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325938 · Cited by 386
Research works printed but not linked: 3
- Bendat J.S., 1986, Random Data: Analysis and Measurement
- Céspedes I., Elastography: Imaging of Biological Tissue Elasticity, Ph.D. Dissertation (Dept. of Electrical Engineering, University of Houston, Texas, 1993).
- Trahey G.E., 1988, IEEE Trans. Biomed. Eng., 34, 965
Cited by
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Self-citationA Least-Squares Strain Estimator for Elastography
Kallel, F., & Ophir, J. (1997) · Ultrasonic Imaging · doi:10.1177/016173469701900303 · Cited by 432
Self-citationA fast normalized cross-correlation calculation method for motion estimation
Luo, J., & Konofagou, E. E. (2010) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1554 · Cited by 384
Direct Localization for Massive MIMO
Garcia, N., Wymeersch, H., Larsson, E. G., Haimovich, A. M., & Coulon, M. (2017) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2017.2666779 · Cited by 379
Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation
Lubinski, M. A., Emelianov, S. Y., & O'Donnell, M. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.741427 · Cited by 379
A theoretical framework for performance characterization of elastography: the strain filter
Varghese, T., & Ophir, J. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.585212 · Cited by 338
“[11] using a rectangular spectrum centered at the Gaussian center frequency with the same mean square amplitude value as the Gaussian spectrum.”
MethodSelf-citationPesavento, A., Perrey, C., Krueger, M., & Ermert, H. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.796111 · Cited by 296
Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo
Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N. (1996) · European Journal of Ultrasound · doi:10.1016/0929-8266(95)00134-4 · Cited by 287
Self-citationPreseismic velocity changes observed from active source monitoring at the Parkfield SAFOD drill site
Niu, F., Silver, P. G., Daley, T. M., et al. (2008) · Nature · doi:10.1038/nature07111 · Cited by 282
Myocardial elastography—a feasibility study in vivo
Konofagou, E. E., D’hooge, J., & Ophir, J. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00488-x · Cited by 264
Self-citation2-D companding for noise reduction in strain imaging
Chaturvedi, P., Insana, M. F., & Hall, T. J. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.646923 · Cited by 231
Lopata, R. G. P., Nillesen, M. M., Hansen, H. H. G., et al. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.11.002 · Cited by 228
Motion Estimation in Ultrasound Images Using Time Domain Cross Correlation With Prior Estimates
Zahiri-Azar, R., & Salcudean, S. E. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.881780 · Cited by 214
“With this technique small displacements are obtained from the position of the maximum peak of the cross-correlation function calculated over a predefined search region between pairs of windowed ultrasonic images that are acquired under different axial deformations (Fig. 1). The exact position of the peak is usually ca…”
MethodInfluentialA spline-based algorithm for continuous time-delay estimation using sampled data
Viola, F., & Walker, W. F. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1397352 · Cited by 194
“Given the largest sample of the “correlation” function, y(0), and its two neighbors y(−1) and y(1), the estimated subsample shift is given by the following expression [31]–[33]:”
BackgroundMethodResultInfluentialNoninvasive evaluation of local myocardial thickening and its color-coded imaging
Kanai, H., Hasegawa, H., Chubachi, N., et al. (1997) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.655190 · Cited by 193
“To improve the estimation precision in the cross-correlation function of subsampled RF signals, several interpolation methods have been proposed and their performances are compared in [33].”
MethodGauging force by tapping tendons
Martin, J. A., Brandon, S. C. E., Keuler, E. M., Hermus, J. R., Ehlers, A. C., Segalman, D. J., Allen, M. S., & Thelen, D. G. (2018) · Nature Communications · doi:10.1038/s41467-018-03797-6 · Cited by 186
Intravascular elasticity imaging using ultrasound: Feasibility studies in phantoms
de Korte, C. L., Céspedes, E. I., van der Steen, A. F. W., et al. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00004-5 · Cited by 191
Intravascular Ultrasound Elastography in Human Arteries: Initial Experience In Vitro
de Korte, C. L., van der Steen, A. F. W., Céspedes, E. I., & Pasterkamp, G. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00280-9 · Cited by 190
Miller, N. R., Bamber, J. C., & Meaney, P. M. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00608-7 · Cited by 172
Linear and nonlinear elasticity imaging of soft tissuein vivo: demonstration of feasibility
Oberai, A. A., Gokhale, N. H., Goenezen, S., Barbone, P. E., Hall, T. J., Sommer, A. M., & Jiang, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/006 · Cited by 162
Ultrasound Elastography: A Dynamic Programming Approach
Rivaz, H. J., Boctor, E. M., Foroughi, P., et al. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.917243 · Cited by 153
Echocardiographic strain and strain-rate imaging: a new tool to study regional myocardial function
D’hooge, J., Bijnens, B. H., Thoen, J., de Werf, F. V., Sutherland, G. R., & Suetens, P. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804440 · Cited by 160
“Several methodologies have been presented and compared in the literature [ 23 ].”
MethodLai, X., & Torp, H. G. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.753016 · Cited by 139
Poroelastography: imaging the poroelastic properties of tissues
Konofagou, E. E., Harrigan, T. P., Ophir, J., et al. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00433-1 · Cited by 135
Self-citationUltrasound Vector Flow Imaging: I: Sequential Systems
Jensen, J. A., Nikolov, S. I., Yu, A. C. H., & Garcia, D. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2600763 · Cited by 148
Intravascular ultrasound elastography: an overview
de Korte, C. L., & van der Steen, A. F. W. (2002) · Ultrasonics · doi:10.1016/s0041-624x(02)00227-5 · Cited by 152
Klibanov, A. L., & Hossack, J. A. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000188 · Cited by 129
Active Source Monitoring of Cross-Well Seismic Travel Time for Stress-Induced Changes
Silver, P. G., Daley, T. M., Niu, F., et al. (2007) · Bulletin of the Seismological Society of America · doi:10.1785/0120060120 · Cited by 126
Noise reduction in elastograms using temporal stretching with multicompression averaging
Varghese, T., Ophir, J., & Céspedes, I. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00128-7 · Cited by 119
Self-citationRenaud, G., Bas, P. L., & Johnson, P. A. (2012) · Journal of Geophysical Research Atmospheres · doi:10.1029/2011jb009127 · Cited by 110
“The peak of the cross-correlation function is interpolated by a second-order polynomial function to achieve sub-sample time delay estimation [Céspedes et al., 1995].”
MethodLateral speckle tracking using synthetic lateral phase
Chen, X., Zohdy, M. J., Emelianov, S., et al. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1320827 · Cited by 110
“Peak detection techniques generally fall into two groups: interpolation methods requiring intensive peak interpolation on the correlation function computed from radio frequency (RF) signals [11], [14], [16], [ 21 ], [22]; and phase-based methods in which the phase of the analytic correlation function crosses zero at t…”
MethodFully Distributed Optical Fiber Strain Sensor With 10 −12 ϵ/√Hz Sensitivity
Costa, L., Martins, H. F., Martín‐López, S., Fernandez-Ruiz, M. R., & González‐Herráez, M. (2019) · Journal of Lightwave Technology · doi:10.1109/jlt.2019.2904560 · Cited by 111
Breast tumor classification using axial shear strain elastography: a feasibility study
Thitaikumar, A., Mobbs, L. M., Kraemer-Chant, C. M., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/022 · Cited by 103
“It has been shown that the correlation coefficient is indicative of the quality of the elastograms (Varghese and Ophir 1997, Céspedes et al 1995).”
BackgroundSelf-citationIntravascular Palpography for Vulnerable Plaque Assessment
Schaar, J. A., van der Steen, A. F. W., Mastik, F., Baldewsing, R. A., & Serruys, P. W. J. C. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.035 · Cited by 116
2024 Recommendations for Validation of Noninvasive Arterial Pulse Wave Velocity Measurement Devices
Spronck, B., Terentes-Printzios, D. G., Avolio, A. P., Boutouyrie, P., Guala, A., Jerončić, A., Laurent, S., Barbosa, E. C. D., Baulmann, J., Chen, C., et al. (2023) · Hypertension · doi:10.1161/hypertensionaha.123.21618 · Cited by 133
Brands, P. J., Hoeks, A. P. G., Ledoux, L. A. F., et al. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00021-5 · Cited by 96
Hansen, H. H. G., Lopata, R. G. P., Idzenga, T., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/11/014 · Cited by 95
“Some authors propose interpolation of RF lines in-between the measured RF lines (Luo and Konofagou 2009) or interpolation of the 2D cross-correlation function (Céspedes et al 1995, Lopata et al 2009); others assume tissue incompressibility (Lubinski et al 1996).”
BackgroundMethodCéspedes, I., Ophir, J., & Alam, S. K. (1997) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.585223 · Cited by 96
Self-citationRivière, J., Shokouhi, P., Guyer, R. A., et al. (2015) · Journal of Geophysical Research Solid Earth · doi:10.1002/2014jb011718 · Cited by 93
“(The shift 𝜏max(tj) is refined by interpolating the peak of the cross-correlation function with a second-order polynomial function to obtain subsample time resolution [Cespedes et al., 1995].”
MethodAdvancing intravascular ultrasonic palpation toward clinical applications
Doyley, M. M., Mastik, F., de Korte, C. L., et al. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00457-4 · Cited by 88
Reconstructive elasticity imaging for large deformations
Skovoroda, A. R., Lubinski, L. A., Emelianov, S., & O’Donnell, M. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.764839 · Cited by 90
Fine elasticity imaging utilizing the iterative RF-echo phase matching method
Sumi, C. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.741527 · Cited by 88
Myocardial Elastography at Both High Temporal and Spatial Resolution for the Detection of Infarcts
Luo, J., Fujikura, K., Homma, S., et al. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.01.019 · Cited by 86
Comparison of time-domain displacement estimators for two-dimensional RF tracking
Langeland, S., D’hooge, J., Torp, H. G., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00972-4 · Cited by 86
Elastographic Imaging of Low-Contrast Elastic Modulus Distributions in Tissue
Kallel, F., Ophir, J., Magee, K., & Krouskop, T. A. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00287-1 · Cited by 87
Self-citationElectromechanical Wave Imaging of Normal and Ischemic HeartsIn Vivo
Provost, J., Lee, W.-N., Fujikura, K., et al. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2030186 · Cited by 84
The variance of quantitative estimates in shear wave imaging: Theory and experiments
Deffieux, T., Gennisson, J., Larrat, B., Fink, M., & Tanter, M. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2472 · Cited by 80
“The time-of-flight algorithm we developed uses crosscorrelation and parabolic interpolation [37] to estimate a time delay dT between the waveforms and thus the local average group velocity c = (xb − xa)/dT between two points along the propagation direction (here, along the x-axis).”
MethodNew real-time strain imaging concepts using diagnostic ultrasound
Pesavento, A., Lorenz, A., Siebers, S., et al. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/302 · Cited by 81
“Furthermore, the post-compression signal has to be time shifted by a subsample time shift (Céspedes et al 1995).”
BackgroundTrade-offs between the axial resolution and the signal-to-noise ratio in elastography
Srinivasan, S. S., Righetti, R., & Ophir, J. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00037-1 · Cited by 81
Self-citationRF-based two-dimensional cardiac strain estimation: a validation study in a tissue-mimicking phantom
Langeland, S., D’hooge, J., Claessens, T. E., Claus, P., Verdonck, P., Suetens, P., Sutherland, G. R., & Bijnens, B. H. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1367495 · Cited by 91
“In order to detect subsample displacements, a cosine function [19] was fitted through three points around the minimum of the sum of squared differences function in axial and azimuth directions.”
MethodTheoretical bounds on strain estimation in elastography
Céspedes, I., Insana, M. F., & Ophir, J. (1995) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.464850 · Cited by 75
“For example, C´ espedes et al. [ 4 ] show that using this substitution, (8) is a reasonable approximation for Gaussian spectra.”
BackgroundMethodSelf-citationShunt Flow Evaluation in Congenital Heart Disease Based on Two-Dimensional Speckle Tracking
Fadnes, S., Nyrnes, S. A., Torp, H. G., & Løvstakken, L. (2014) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.03.029 · Cited by 80
A quality-guided displacement tracking algorithm for ultrasonic elasticity imaging
Chen, L., Treece, G. M., Lindop, J. E., et al. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.10.007 · Cited by 75
“Eorts have been made to adapt the correlation algorithm to provide subsample accuracy [ 4 ].”
MethodPerformance Optimization in Elastography: Multicompression with Temporal Stretching
Varghese, T., & Ophir, J. (1996) · Ultrasonic Imaging · doi:10.1177/016173469601800303 · Cited by 74
Self-citationThe nonstationary strain filter in elastography: Part II. Lateral and elevational decorrelation
Kallel, F., Varghese, T., Ophir, J., & Bilgen, M. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00196-8 · Cited by 73
“This difference is referred to as speckle decorrelation (Meunier and Bertrand 1995; Cespedes et al. 1995).”
BackgroundMethodSelf-citationShear Wave Predictions of Achilles Tendon Loading during Human Walking
Keuler, E. M., Loegering, I. F., Martin, J. A., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-49063-7 · Cited by 73
Swillens, A., Segers, P., Torp, H. G., & Løvstakken, L. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1413 · Cited by 74
“also, local parabolic fitting around the sad matrix minimum was employed to achieve subpixel accuracy [24].”
MethodExploration of trabecular bone nonlinear elasticity using time-of-flight modulation
Renaud, G., Callé, S., Réméniéras, J.-P., & Defontaine, M. (2008) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.825 · Cited by 73
“These TOF variations are more accurately estimated using the threepoints parabolic interpolation [30].”
MethodA Generalized Speckle Tracking Algorithm for Ultrasonic Strain Imaging Using Dynamic Programming
Jiang, J., & Hall, T. J. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.05.016 · Cited by 78
Renaud, G., Rivière, J., Haupert, S., et al. (2013) · The Journal of the Acoustical Society of America · doi:10.1121/1.4802909 · Cited by 70
3D elastography using freehand ultrasound
Lindop, J. E., Treece, G. M., Gee, A. H., et al. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.11.018 · Cited by 69
Intravascular Palpography for High-Risk Vulnerable Plaque Assessment
Schaar, J. A., de Korte, C. L., Mastik, F., Baldewsing, R. A., Regar, E. S., de Feyter, P. J., Slager, C. J., van der Steen, A. F. W., & Serruys, P. W. J. C. (2003) · Herz · doi:10.1007/s00059-003-2488-6 · Cited by 89
“The tissue under inspection is deformed, and the strain between pairs of ultrasound signals with and without deformation is determined [ 17 ].”
BackgroundA parallelizable real-time motion tracking algorithm with applications to ultrasonic strain imaging
Jiang, J., & Hall, T. J. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/13/008 · Cited by 69
Effects of Various Parameters on Lateral Displacement Estimation in Ultrasound Elastography
Luo, J., & Konofagou, E. E. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.03.001 · Cited by 75
Measurement of tendon strain during muscle twitch contractions using ultrasound elastography
Farron, J., Varghese, T., & Thelen, D. G. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1002 · Cited by 67
Anand, A. J., Savéry, D., & Hall, C. S. (2007) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.208 · Cited by 66
“Time shifts smaller than one RF sampling period are estimated by locating the maximum of a parabola that is fit around the peak of the crosscorrelation function [ 20 ], using three adjacent RF samples.”
MethodSvilainis, L., Lukoševičiūtė, K., Dumbrava, V., et al. (2013) · Measurement · doi:10.1016/j.measurement.2013.07.038 · Cited by 65
A novel performance descriptor for ultrasonic strain imaging: a preliminary study
Jiang, J., Hall, T. J., & Sommer, A. M. (2006) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1642508 · Cited by 66
Echo decorrelation from displacement gradients in elasticity and velocity estimation
Céspedes, E. I., de Korte, C. L., & van der Steen, A. F. W. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.775642 · Cited by 66
“This is a reasonable rst order approximation for Gaussian and flat spectra [ 39 ], [40], which span a range of spectral shapes representative of most ultrasound instruments.”
BackgroundCui, J., Zhao, S., Yang, D., et al. (2018) · Applied Optics · doi:10.1364/ao.57.001424 · Cited by 60
Real-time quasi-static ultrasound elastography
Treece, G. M., Lindop, J. E., Chen, L., Housden, R. J., Prager, R. W., & Gee, A. H. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0011 · Cited by 59
A coupled subsample displacement estimation method for ultrasound-based strain elastography
Jiang, J., & Hall, T. J. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/21/8347 · Cited by 59
Robust angle-independent blood velocity estimation based on dual-angle plane wave imaging
Fadnes, S., Ekroll, I. K., Nyrnes, S. A., Torp, H. G., & Løvstakken, L. (2015) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2015.007108 · Cited by 63
Azar, R. Z., Göksel, O., & Salcudean, S. E. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1708 · Cited by 60
On time delay estimation and sampling error in resting-state fMRI
Raut, R. V., Mitra, A., Snyder, A. Z., & Raichle, M. E. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.020 · Cited by 63
“3C, left) is a well-known characteristic of parabolic interpolation (Boucher and Hassab, 1981; Céspedes et al., 1995) and effectively biases estimates toward the nearest TR.”
BackgroundEcho speckle imaging of blood particles with high-frame-rate echocardiography
Takahashi, H., Hasegawa, H., & Kanai, H. (2014) · Japanese Journal of Applied Physics · doi:10.7567/jjap.53.07kf08 · Cited by 55
A novel interpolation strategy for estimating subsample speckle motion
Geiman, B. J., Bohs, L. N., Anderson, M. E., et al. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/310 · Cited by 52
Costa‐Júnior, J. F. S., Cortela, G. A., Maggi, L. E., Rocha, T. F. D., Pereira, W. C. D. A., Costa-Felix, R. P. B., & Alvarenga, A. V. (2018) · Measurement · doi:10.1016/j.measurement.2018.01.073 · Cited by 50
Cardiac Strain Imaging With Coherent Compounding of Diverging Waves
Grondin, J., Sayseng, V., & Konofagou, E. E. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2717792 · Cited by 47
A two-step optical flow method for strain estimation in elastography: Simulation and phantom study
Pan, X., Gao, J. S., Tao, S., Liu, K., Bai, J., & Luo, J. (2013) · Ultrasonics · doi:10.1016/j.ultras.2013.11.010 · Cited by 52
A high accuracy magnetostrictive linear position sensor
Seco, F. A., Martín, J. M. M., Jiménez, A. R., et al. (2005) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2005.02.026 · Cited by 46
“One method to estimate the time delay D12 with subsample precision consists in fitting an analytical curve to the three samples closest to the discrete maximum [12] (note that this requires a minimum sampling frequency fs > 6f0 in order to have at least three points in the positive semi-cycle of the correlation vector…”
MethodGastounioti, A., Golemati, S., Stoitsis, J. S., & Nikita, K. S. (2011) · Measurement Science and Technology · doi:10.1088/0957-0233/22/11/114008 · Cited by 45
Error analysis in acoustic elastography. I. Displacement estimation
Bilgen, M., & Insana, M. F. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.418018 · Cited by 45
Continuous subsurface velocity measurement with coda wave interferometry
Wang, B., Zhu, P., Chen, Y., et al. (2008) · Journal of Geophysical Research Atmospheres · doi:10.1029/2007jb005023 · Cited by 44
“…obtain sub-sample precision for the time delay estimation, three different methods were applied to the data: (1) a linear interpolation of the seismograms; (2) a cubic spline interpolation of the seismograms; and (3) a cosine curve fitting of the correlation function [e.g., Céspedes et al., 1995].”
MethodInfluence of catheter position on estimated strain in intravascular elastography
de Korte, C. L., Céspedes, E. I., & Steen, A. F. W. V. D. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.764848 · Cited by 44
“To increase the resolution of the time-delay estimation, the correlation coefficient function was upsampled 50 times [5], [25].”
MethodImproving the Accuracy of Magnetostrictive Linear Position Sensors
Seco, F. A., Martín, J. M. M., & Jiménez, A. R. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.2005260 · Cited by 44
Performance of time delay estimation methods for small time shifts in ultrasonic signals
de Korte, C. L., van der Steen, A. F. W., Dijkman, B. H. J., & Lancée, C. T. (1997) · Ultrasonics · doi:10.1016/s0041-624x(97)00016-4 · Cited by 42
Harmonic Motion Imaging (HMI) for Tumor Imaging and Treatment Monitoring
Konofagou, E. E., Maleke, C., & Vappou, J. (2012) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/157340512799220616 · Cited by 47
Competition between preslip and deviatoric stress modulates precursors for laboratory earthquakes
Shreedharan, S., Bolton, D. C., Rivière, J., & Marone, C. J. (2020) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2020.116623 · Cited by 40
Review on Time Delay Estimate Subsample Interpolation in Frequency Domain
Svilainis, L. (2019) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2019.2930661 · Cited by 40
“Simple, cosine interpolation was used in comparison: this technique is fast and has predictable bias error [14], [22], which is the lowest among the simplest interpolators.”
BackgroundMethodInfluentialDecorrelation of intravascular echo signals: Potentials for blood velocity estimation
Li, W., Lancée, C. T., Céspedes, E. I., van der Steen, A. F. W., & Bom, N. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.420141 · Cited by 38
In situ characterization of shallow elastic nonlinear parameters with Dynamic Acoustoelastic Testing
Renaud, G., Rivière, J., Larmat, C. S., et al. (2014) · Journal of Geophysical Research Solid Earth · doi:10.1002/2013jb010625 · Cited by 38
Ternifi, R., Cazals, X., Desmidt, T., Andersson, F., Camus, V., Cottier, J., Patat, F., & Réméniéras, J.-P. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.58 · Cited by 36
Jin, J., Rivière, J., Ohara, Y., et al. (2018) · Journal of Applied Physics · doi:10.1063/1.5036531 · Cited by 37
Similar microearthquakes observed in western Nagano, Japan, and implications for rupture mechanics
Cheng, X., Niu, F., Silver, P. G., et al. (2007) · Journal of Geophysical Research Atmospheres · doi:10.1029/2006jb004416 · Cited by 37
“In our study, we employed a cosine fitting method to estimate subsample delay time in the time domain [De Jong et al., 1990; Cespedes et al., 1995].”
MethodSubsample interpolation strategies for sensorless freehand 3D ultrasound
Housden, R. J., Gee, A. H., Treece, G. M., & Prager, R. W. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.06.027 · Cited by 37
“More prone to bias are cosine [3, 5, 6], cubic spline [9] and parabolic interpolation [2, 3, 7].”
BackgroundDoyley, M. M., Srinivasan, S., Dimidenko, E., et al. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/1/007 · Cited by 37
Self-citationA hybrid displacement estimation method for ultrasonic elasticity imaging
Chen, L., Housden, R. J., Treece, G. M., Gee, A. H., & Prager, R. W. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1491 · Cited by 35
Needle-tissue interaction modeling using ultrasound-based motion estimation: Phantom study
Dehghan, E., Wen, X., Zahiri-Azar, R., Marchal, M., & Salcudean, S. E. (2008) · Computer Aided Surgery · doi:10.3109/10929080802383173 · Cited by 40
Honjo, Y., Hasegawa, H., & Kanai, H. (2010) · Japanese Journal of Applied Physics · doi:10.1143/jjap.49.07hf14 · Cited by 35
Metadata
- Authors
- Céspedes, I., Huang, Y., Ophir, J., & Spratt, S.
- Affiliations
- The University of Texas Medical School Radiology Department - Ultrasonics Laboratory Houston, TX 77030
- Diasonics Ultrasound Inc. San Jose, CA
- ORCID
- Céspedes, I.
- Venue
- Ultrasonic Imaging
- Publisher
- SAGE Publications
- Published
- 1995-04
- Volume
- 17
- Issue
- 2
- Pages
- 142-171
- ISSN
- 0161-7346 (ISSN-L)
- 1096-0910
- OpenAlex
- W2044310882
- Cited by
- 436
- References
- 28
- Citations by year
- 2026: 10 · 2025: 15 · 2024: 11 · 2023: 21 · 2022: 16 · 2021: 17 · 2020: 19 · 2019: 25 · 2018: 22 · 2017: 18 · 2016: 10 · 2015: 20 · 2014: 21 · 2013: 17 · 2012: 16
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Ultrasonic Imaging (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca038515-07, 5r01ca060520-03)
- National Cancer Institute (R01-CA60520, P01-CA64579, R01-CA-38515)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Physical Sciences › Earth and Planetary Sciences › Oceanography › Underwater Acoustics Research
- Keywords
- time delay estimation, echo signal, cross correlation function, interpolation, parabolic interpolation, curve fitting, reconstruction filter, maximum likelihood estimation, bias, elastography, iterative reconstruction
- MeSH terms
- Computer Simulation, Humans, Image Processing, Computer-Assisted, Signal Processing, Computer-Assisted, Time Factors, Ultrasonography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.