The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Multi-Angle Compound Imaging
Abstract
This paper reports on a scanning technique, denoted multi-angle compound imaging (MACI), using spatial compounding. The MACI method also contains elements of frequency compounding, as the transmit frequency is lowered for the highest beam angles in order to reduce grating lobes. Compared to conventional B-mode imaging MACI offers better defined tissue boundaries and lower variance of the speckle pattern, resulting in an image with reduced random variations. Design and implementation of a compound imaging system is described, images of rubber tubes and porcine aorta are shown and effects on visualization are discussed. The speckle reduction is analyzed numerically and the results are found to be in excellent agreement with existing theory. An investigation of detectability of low-contrast lesions shows significant improvements compared to conventional imaging. Finally, possibilities for improving diagnosis of atherosclerotic diseases using MACI are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid Stenosis
(1991) · New England Journal of Medicine · doi:10.1056/nejm199108153250701 · Cited by 8,368
Splitting the unit delay [FIR/all pass filters design]
Laakso, T. I., Valimaki, V., Karjalainen, M., & Laine, U. K. (1996) · IEEE Signal Processing Magazine · doi:10.1109/79.482137 · Cited by 1,168
Cited by
Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,814
Ultrasonic Echolucent Carotid Plaques Predict Future Strokes
Grønholdt, M.-L. M., Nordestgaard, B. G., Schroeder, T. V., Vorstrup, S., & Sillesen, H. (2001) · Circulation · doi:10.1161/hc2601.091704 · Cited by 577
Self-citationUltrafast compound imaging for 2-D motion vector estimation: application to transient elastography
Tanter, M., Bercoff, J., Sandrin, L., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1041078 · Cited by 414
Image-Based Computational Fluid Dynamics Modeling in Realistic Arterial Geometries
Steinman, D. A. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1467679 · Cited by 381
Metadata
- Authors
- Jespersen, S. K., Wilhjelm, J. E., & Sillesen, H.
- Venue
- Ultrasonic Imaging
- Publisher
- SAGE Publications
- Published
- 1998-04
- Volume
- 20
- Issue
- 2
- Pages
- 81-102
- ISSN
- 0161-7346 (ISSN-L)
- 1096-0910
- OpenAlex
- W2085148278
- Cited by
- 205
- References
- 2
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.