The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Elastic Moduli of Breast and Prostate Tissues under Compression
Abstract
To evaluate the dynamic range of tissue imaged by elastography, the mechanical behavior of breast and prostate tissue samples subject to compression loading has been investigated. A model for the loading was validated and used to guide the experimental design for data collection. The model allowed the use of small samples that could be considered homogeneous; this assumption was confirmed by histological analysis. The samples were tested at three strain rates to evaluate the viscoelastic nature of the material and determine the validity of modeling the tissue as an elastic material for the strain rates of interest. For loading frequencies above 1 Hz, the storage modulus accounted for over 93 percent of the complex modulus. The data show that breast fat tissue has a constant modulus over the strain range tested while the other tissues have a modulus that is dependent on the strain level. The fibrous tissue samples from the breast were found to be 1 to 2 orders of magnitude stiffer than fat tissue. Normal glandular breast tissue was found to have an elastic modulus similar to that of fat at low strain levels, but the modulus of the glandular tissue increased by an order of magnitude above fat at high strain levels. Carcinomas from the breast were stiffer than the other tissues at the higher strain level; intraductal in situ carcinomas were like fat at the low strain level and much stiffer than glandular tissue at the high strain level. Infiltrating ductal carcinomas were much stiffer than any of the other breast tissues. Normal prostate tissue has a modulus that is lower than the modulus of the prostate cancers tested. Tissue from prostate with benign prostatic hyperplasia (BPH) had modulus values significantly lower than normal tissue. There was a constant but not significant difference in the modulus of tissues taken from the anterior and posterior portions of the gland.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Elastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940
Self-citationStrength of biological materials
Roberts, V. L. (1971) · Journal of Biomechanics · doi:10.1016/0021-9290(71)90027-3 · Cited by 566
Phantom materials for elastography
Hall, T. J., Bilgen, M., Insana, M. F., & Krouskop, T. A. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.656639 · Cited by 516
Self-citationImaging of the elastic properties of tissue—A review
Gao, L., Parker, K. J., Lerner, R. M., & Levinson, S. F. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00120-2 · Cited by 514
Tissue response to mechanical vibrations for “sonoelasticity imaging”
Parker, K. J., Huang, S. R., Musulin, R. A., & Lerner, R. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90003-u · Cited by 478
A note on the elasticity of soft biological tissues
Demiray, H. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90047-4 · Cited by 416
Elastography: Elasticity Imaging Using Ultrasound with Application to Muscle and Breast In Vivo
Cespedes, I. (1993) · Ultrasonic Imaging · doi:10.1006/uimg.1993.1007 · Cited by 414
Krouskop, T. A., Dougherty, D. R., & Vinson, F. S. (1987) · PubMed · Cited by 362
Self-citationYoung's modulus measurements of soft tissues with application to elasticity imaging
Chen, E. J., Novakofski, J., Jenkins, W. K., & O'Brien, W. D. (1996) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.484478 · Cited by 312
Cited by
Matrix Crosslinking Forces Tumor Progression by Enhancing Integrin Signaling
Levental, K. R., Yu, H., Kass, L., Lakins, J. N., Egeblad, M., Erler, J. T., Fong, S. F. T., Csiszar, K., Giaccia, A., Weninger, W., et al. (2009) · Cell · doi:10.1016/j.cell.2009.10.027 · Cited by 4,101
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Breast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Bamber, J., Cosgrove, D., Dietrich, C., Fromageau, J., Bojunga, J., Calliada, F., Cantisani, V., Correas, J.-M., D'Onofrio, M., Drakonaki, E., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335205 · Cited by 1,198
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Shiina, T., Nightingale, K. R., Palmeri, M. L., Hall, T. J., Bamber, J. C., Barr, R. G., Castera, L., Choi, B. I., Chou, Y.-H., Cosgrove, D., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.009 · Cited by 958
Self-citationCosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
Berg, W. A., Cosgrove, D. O., Doré, C. J., Schäfer, F. K. W., Svensson, W. E., Hooley, R. J., Ohlinger, R., Mendelson, E. B., Balu-Maestro, C., Locatelli, M., et al. (2012) · Radiology · doi:10.1148/radiol.11110640 · Cited by 845
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Self-citationLiu, J., & Roberts, C. J. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.031 · Cited by 753
On the feasibility of remote palpation using acoustic radiation force
Nightingale, K. R., Palmeri, M. L., Nightingale, R. W., & Trahey, G. E. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1378344 · Cited by 731
Dehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D. (2009) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1162 · Cited by 728
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708
Samani, A., Zubovits, J., & Plewes, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/6/002 · Cited by 707
Needle insertion into soft tissue: A survey
Abolhassani, N., Patel, R., & Moallem, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.07.003 · Cited by 704
Magnetic resonance elastography: A review
Mariappan, Y. K., Glaser, K. J., & Ehman, R. L. (2010) · Clinical Anatomy · doi:10.1002/ca.21006 · Cited by 680
Provenzano, P. P., Inman, D. R., Eliceiri, K. W., & Keely, P. J. (2009) · Oncogene · doi:10.1038/onc.2009.299 · Cited by 675
Selected Methods for Imaging Elastic Properties of Biological Tissues
Greenleaf, J. F., Fatemi, M., & Insana, M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121623 · Cited by 671
Nonholonomic Modeling of Needle Steering
Webster, R. J., Kim, J. S., Cowan, N. J., Chirikjian, G. S., & Okamura, A. M. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065388 · Cited by 633
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
Nonholonomic Modeling of Needle Steering
Webster, R. J., Cowan, N. J., Chirikjian, G., & Okamura, A. M. (2006) · Springer Tracts in Advanced Robotics · doi:10.1007/11552246_4 · Cited by 527
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
The Tension Mounts: Mechanics Meets Morphogenesis and Malignancy
Paszek, M. J., & Weaver, V. M. (2004) · Journal of Mammary Gland Biology and Neoplasia · doi:10.1007/s10911-004-1404-x · Cited by 467
Elastic modulus measurements of human liver and correlation with pathology
Yeh, W.-C., Li, P.-C., Jeng, Y.-M., Hsu, H.-C., Kuo, P.-L., Li, M.-L., Yang, P.-M., & Lee, P. H. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00489-1 · Cited by 458
The tumor microenvironment is a dominant force in multidrug resistance
Correia, A. L., & Bissell, M. J. (2012) · Drug Resistance Updates · doi:10.1016/j.drup.2012.01.006 · Cited by 443
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Optical coherence elastography – OCT at work in tissue biomechanics [Invited]
Larin, K. V., & Sampson, D. D. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001172 · Cited by 428
Discrimination Between Normal and Cancerous Cells Using AFM
Lekka, M. (2016) · BioNanoScience · doi:10.1007/s12668-016-0191-3 · Cited by 414
Shear Wave Spectroscopy for In Vivo Quantification of Human Soft Tissues Visco-Elasticity
Deffieux, T., Montaldo, G., Tanter, M., & Fink, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.925077 · Cited by 411
Shear wave elastography for breast masses is highly reproducible
the BE1 Study Group, Cosgrove, D. O., Berg, W. A., Doré, C. J., Skyba, D. M., Henry, J.-P., Gay, J., & Cohen-Bacrie, C. (2012) · European Radiology · doi:10.1007/s00330-011-2340-y · Cited by 406
In vivo real-time freehand palpation imaging
Hall, T. J., Zhu, Y., & Spalding, C. S. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00733-0 · Cited by 394
Self-citationMR Elastography of Breast Cancer: Preliminary Results
McKnight, A. L., Kugel, J. L., Rossman, P. J., Manduca, A., Hartmann, L. C., & Ehman, R. L. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781411 · Cited by 381
Imaging anisotropic and viscous properties of breast tissue by magnetic resonance‐elastography
Sinkus, R., Tanter, M., Catheline, S., Lorenzen, J., Kuhl, C., Sondermann, E., & Fink, M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20355 · Cited by 380
Elastography: Imaging the elastic properties of soft tissues with ultrasound
Ophir, J., Alam, S. K., Garra, B. S., Kallel, F., Konofagou, E. E., Krouskop, T., Merritt, C. R. B., Righetti, R., Souchon, R., Srinivasan, S., et al. (2002) · Journal of Medical Ultrasonics · doi:10.1007/bf02480847 · Cited by 366
Self-citationHuman tactile perception as a standard for artificial tactile sensing—a review
Dargahi, J., & Najarian, S. (2004) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.3 · Cited by 369
Biomimetic 3D tissue printing for soft tissue regeneration
Pati, F., Ha, D.-H., Jang, J., Han, H. H., Rhie, J.-W., & Cho, D.-W. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.05.043 · Cited by 368
Mechanical properties of whole-body soft human tissues: a review
Singh, G., & Chanda, A. (2021) · Biomedical Materials · doi:10.1088/1748-605x/ac2b7a · Cited by 364
Pearce, O. M. T., Delaine-Smith, R. M., Maniati, E., Nichols, S., Wang, J., Böhm, S., Rajeeve, V., Ullah, D., Chakravarty, P., Jones, R. R., et al. (2018) · Cancer Discovery · doi:10.1158/2159-8290.cd-17-0284 · Cited by 349
Tissue characterization using magnetic resonance elastography: preliminary results*
Kruse, S. A., Smith, J. A., Lawrence, A. J., Dresner, M. A., Manduca, A., Greenleaf, J. F., Ehman, R. L., Kruse, S. A., Smith, J. A., Lawrence, A. J., et al. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/313 · Cited by 340
A Review of Optical Coherence Elastography: Fundamentals, Techniques and Prospects
Kennedy, B. F., Kennedy, K. M., & Sampson, D. D. (2014) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2013.2291445 · Cited by 334
Real-Time Elastography for Noninvasive Assessment of Liver Fibrosis in Chronic Viral Hepatitis
Friedrich-Rust, M., Ong, M.-F., Herrmann, E., Dries, V., Samaras, P., Zeuzem, S., & Sarrazin, C. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0322 · Cited by 325
Model-based elastography: a survey of approaches to the inverse elasticity problem
Doyley, M. M. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/3/r35 · Cited by 319
Extracellular Matrix Rigidity Promotes Invadopodia Activity
Alexander, N. R., Branch, K. M., Parekh, A., Clark, E. S., Iwueke, I. C., Guelcher, S. A., & Weaver, A. M. (2008) · Current Biology · doi:10.1016/j.cub.2008.07.090 · Cited by 317
Iglesias–Garcia, J., Larino–Noia, J., Abdulkader, I., Forteza, J., & Dominguez–Munoz, J. E. (2010) · Gastroenterology · doi:10.1053/j.gastro.2010.06.059 · Cited by 314
Three-dimensional context regulation of metastasis
Erler, J. T., & Weaver, V. M. (2009) · Clinical & Experimental Metastasis · doi:10.1007/s10585-008-9209-8 · Cited by 313
Tissue elasticity properties as biomarkers for prostate cancer
Hoyt, K., Castaneda, B., Zhang, M., Nigwekar, P., di Sant'Agnese, P. A., Joseph, J. V., Strang, J., Rubens, D. J., & Parker, K. J. (2008) · Cancer Biomarkers · doi:10.3233/cbm-2008-44-505 · Cited by 303
Differentiating Benign from Malignant Solid Breast Masses with US Strain Imaging
Burnside, E. S., Hall, T. J., Sommer, A. M., Hesley, G. K., Sisney, G. A., Svensson, W. E., Fine, J. P., Jiang, J., & Hangiandreou, N. J. (2007) · Radiology · doi:10.1148/radiol.2452061805 · Cited by 296
Self-citationMeasuring the elastic modulus of ex vivo small tissue samples
Samani, A., Bishop, J., Luginbuhl, C., & Plewes, D. B. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/14/310 · Cited by 295
Mierke, C. T. (2019) · Reports on Progress in Physics · doi:10.1088/1361-6633/ab1628 · Cited by 262
Kennedy, K. M., Chin, L., McLaughlin, R. A., Latham, B., Saunders, C. M., Sampson, D. D., & Kennedy, B. F. (2015) · Scientific Reports · doi:10.1038/srep15538 · Cited by 261
Barr, R. G., Cosgrove, D., Brock, M., Cantisani, V., Correas, J. M., Postema, A. W., Salomon, G., Tsutsumi, M., Xu, H.-X., & Dietrich, C. F. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.06.020 · Cited by 259
Mechanics of the normal woman's breast
Gefen, A., & Dilmoney, B. (2007) · Technology and Health Care · doi:10.3233/thc-2007-15404 · Cited by 257
Initial in vivo experience with steady‐state subzone‐based MR elastography of the human breast
Van Houten, E. E. W., Doyley, M. M., Kennedy, F. E., Weaver, J. B., & Paulsen, K. D. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10232 · Cited by 224
“[2] can then be used to create the alternative elastic parameter distributions E and , while the variances for these parameters can be estimated by error propagation, where”
MethodMatrix stiffness regulates macrophage polarisation via the Piezo1‐YAP signalling axis
Mei, F., Guo, Y., Wang, Y., Zhou, Y., Heng, B. C., Xie, M., Huang, X., Zhang, S., Ding, S., Liu, F., et al. (2024) · Cell Proliferation · doi:10.1111/cpr.13640 · Cited by 118
“36 The stiffness value (10 – 323 kPa) of the PA gels we used represents a wide range of stiffness encountered in both healthy and diseased tissues.”
Method
Metadata
- Authors
- Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T.
- Venue
- Ultrasonic Imaging
- Publisher
- SAGE Publications
- Published
- 1998-10
- Volume
- 20
- Issue
- 4
- Pages
- 260-274
- ISSN
- 0161-7346 (ISSN-L)
- 1096-0910
- OpenAlex
- W2071027495
- Cited by
- 1,703
- References
- 24
- FWCI
- 12.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.