CoChat

Accumulation of Iron in the Rat Lung after Tracheal Instillation of Diesel Particles

Open access
Ghio, Andrew J., Richards, Judy H., Carter, Jacqueline D., Madden, Michael C. · 2000 · Toxicologic Pathology
Cited by 59

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Oxidant generation catalyzed by metals has been postulated to account for a lung injury following exposure to air pollution particles. In particles that are predominantly carbonaceous, it is difficult to implicate such an oxidative stress as the responsible mechanism, since concentrations of metals can be extremely low. Comparable to these air pollution particles, mineral oxide particles can include only minute amounts of metal, but lung injury following their exposure can be associated with an accumulation of endogenous iron from the host and an oxidative stress. We tested the hypothesis that diesel exhaust particulate (DEP) effects an accumulation of biologically active iron in the rat lung, with both oxidative stress and a lung injury resulting. Characterization of the DEP confirmed a high concentration of carbon, whereas metals were low in quantity. The concentration of total lavage iron in animals instilled with saline was low, but this concentration increased with exposure to DEP. Non-heme iron in lung tissue was similarly elevated after instillation of the diesel product. Particle instillation was associated with a decrease in lavage ascorbate concentration supporting an oxidative stress. Relative to saline exposure, DEP resulted in elevated lavage concentrations of the inflammatory mediators macrophage inflammatory protein-2 and tumor necrosis factor. Finally, an injury after particle instillation was evident with increased neutrophils and an elevation of lavage protein and lactic dehydrogenase. We conclude that DEP exposure effected an accumulation of iron in the rat lung. This accrual of iron was associated with an oxidative stress, release of oxidant-sensitive mediators, and a neutrophilic lung injury.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/019262330002800416

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 59

Metadata

Authors
Ghio, A. J., Richards, J. H., Carter, J. D., & Madden, M. C.
Venue
Toxicologic Pathology
Published
2000-07
Volume
28
Issue
4
Pages
619-627
ISSN
  • 0192-6233 (ISSN-L)
  • 1533-1601
OpenAlex
W2168036035
Cited by
59
References
2
FWCI
4.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accumulation of Iron in the Rat Lung after Tracheal Instillation of Diesel Particles. https://app.cochat.ai/papers/10.1177/019262330002800416
The paper
Ghio, A. J., Richards, J. H., Carter, J. D., & Madden, M. C. (2000). Accumulation of Iron in the Rat Lung after Tracheal Instillation of Diesel Particles. Toxicologic Pathology. https://doi.org/10.1177/019262330002800416

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.