Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 700

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Cyclodextrins

Stella, Valentino J., He, Quanren·2008·Toxicologic Pathology

Abstract

β-cyclodextrin (β-CD) and other cyclodextrins (CDs) have utility for solubilizing and stabilizing drugs; however, some are nephrotoxic when administered parenterally. A number of workers have attempted to identify, prepare, and evaluate various CD derivatives with superior inclusion complexation and maximal in vivo safety for various biomedical uses. A systematic study led to SBE-β-CD (Captisol), a polyanionic variably substituted sulfobutyl ether of β-CD, as a non-nephrotoxic derivative and HP-β-CD, a modified CD developed by Janssen. SBE-β-CD and HP-β-CD have undergone extensive safety studies and are currently used in six products approved by the Food and Drug Administration (four for Captisol and two for HP-β-CD). They are also in use in numerous clinical and preclinical studies. This article will focus on the issues that led to the development of these two CDs, their safety, characterization, and applications, and especially their ability to improve drug delivery. SBE-β-CD interacts very well with neutral drugs to facilitate solubility and chemical stability, and because of its polyanionic nature, it interacts particularly well with cationic drugs. Complexes between SBE-β-CD and HP-β-CD and various drugs have been shown to rapidly dissociate after parenteral drug administration, to have no tissue-irritating effects after intramuscular dosing, and to result in superior oral bioavailability of poorly water-soluble drugs. The pharmacokinet-ics, tissue distribution, and cellular effects of some representative CDs, including SBE-β-CD and HP-β-CD, are reviewed. The safety profiles of CDs are discussed, with emphasis on the biological effects of some CDs on the gastrointestinal tract, kidney, and reproduction and development and the carcinogenic potential of CDs. In addition, human experience with CD derivatives, specifically SBE-β-CD and HP-β-CD, indicates that these two CDs are well tolerated in humans and have no adverse effects on the kidneys or other organs following either oral or intravenous administration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0192623307310945

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 700

Metadata

Authors
Stella, V. J., & He, Q.
Venue
Toxicologic Pathology
Published
2008-01
Volume
36
Issue
1
Pages
30-42
ISSN
  • 0192-6233 (ISSN-L)
  • 1533-1601
OpenAlex
W4247852925
Cited by
700
References
2
FWCI
15.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.