The DOI matches its Crossref record.
Biocompatibility: Meeting a Key Functional Requirement of Next-Generation Medical Devices
Open accessAbstract
The array of polymeric, biologic, metallic, and ceramic biomaterials will be reviewed with respect to their biocompatibility, which has traditionally been viewed as a requirement to develop a safe medical device. With the emergence of combination products, a paradigm shift is occurring that now requires biocompatibility to be designed into the device. In fact, next-generation medical devices will require enhanced biocompatibility by using, for example, pharmacological agents, bioactive coatings, nanotextures, or hybrid systems containing cells that control biologic interactions to have desirable biologic outcomes. The concept of biocompatibility is moving from a “do no harm” mission (i.e., nontoxic, nonantigenic, nonmutagenic, etc.) to one of doing “good,” that is, encouraging positive healing responses. These new devices will promote the formation of normal healthy tissue as well as the integration of the device into adjacent tissue. In some contexts, biocompatibility can become a disruptive technology that can change therapeutic paradigms (e.g., drug-coated stents). New database tools to access biocompatibility data of the materials of construction in existing medical devices will facilitate the use of existing and new biomaterials for new medical device designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Oxidized Alginate-Based Hydrogels for Tissue Engineering Applications: A Review
Reakasame, S., & Boccaccini, A. R. (2018) · Biomacromolecules · doi:10.1021/acs.biomac.7b01331 · Cited by 408
Zhang, J., Rector, J., Lin, J. Q., Young, J. H., Sans, M., Katta, N., Giese, N., Yu, W., Nagi, C., Suliburk, J., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aan3968 · Cited by 406
Biological responses to physicochemical properties of biomaterial surface
Rahmati, M., Silva, E. A., Reseland, J. E., A. Heyward, C., & Haugen, H. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00103a · Cited by 391
Arifin, A., Sulong, A. B., Muhamad, N., Syarif, J., & Ramli, M. I. (2014) · Materials & Design · doi:10.1016/j.matdes.2013.09.045 · Cited by 349
Biocompatibility assessment of biomaterials used in orthopedic devices: An overview (Review)
Huzum, B., Puha, B., Necoara, R., Gheorghevici, S., Puha, G., Filip, A., Sirbu, P., & Alexa, O. (2021) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2021.10750 · Cited by 253
Metadata
- Authors
- Helmus, M. N., Gibbons, D. F., & Cebon, D.
- Venue
- Toxicologic Pathology
- Publisher
- SAGE Publications
- Published
- 2008-01
- Volume
- 36
- Issue
- 1
- Pages
- 70-80
- ISSN
- 0192-6233 (ISSN-L)
- 1533-1601
- OpenAlex
- W2142960025
- Cited by
- 170
- References
- 0
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatibility: Meeting a Key Functional Requirement of Next-Generation Medical Devices. https://app.cochat.ai/papers/10.1177/0192623307310949
- The paper
- Helmus, M. N., Gibbons, D. F., & Cebon, D. (2008). Biocompatibility: Meeting a Key Functional Requirement of Next-Generation Medical Devices. Toxicologic Pathology. https://doi.org/10.1177/0192623307310949
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.