Biocompatibility: Meeting a Key Functional Requirement of Next-Generation Medical Devices
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
The array of polymeric, biologic, metallic, and ceramic biomaterials will be reviewed with respect to their biocompatibility, which has traditionally been viewed as a requirement to develop a safe medical device. With the emergence of combination products, a paradigm shift is occurring that now requires biocompatibility to be designed into the device. In fact, next-generation medical devices will require enhanced biocompatibility by using, for example, pharmacological agents, bioactive coatings, nanotextures, or hybrid systems containing cells that control biologic interactions to have desirable biologic outcomes. The concept of biocompatibility is moving from a “do no harm” mission (i.e., nontoxic, nonantigenic, nonmutagenic, etc.) to one of doing “good,” that is, encouraging positive healing responses. These new devices will promote the formation of normal healthy tissue as well as the integration of the device into adjacent tissue. In some contexts, biocompatibility can become a disruptive technology that can change therapeutic paradigms (e.g., drug-coated stents). New database tools to access biocompatibility data of the materials of construction in existing medical devices will facilitate the use of existing and new biomaterials for new medical device designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Sousa, J. E., Costa, M. A., Abizaid, A., Abizaid, A. S., Feres, F., Pinto, I. M. F., Seixas, A. C., Staico, R., Mattos, L. A., Sousa, A. G. M. R., et al. (2001) · Circulation · doi:10.1161/01.cir.103.2.192 · Cited by 793
Biocompatibility of clinical implant materials
Williams, D. F. (1981) · CRC Press eBooks · Cited by 773
Stent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model
Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., Klugherz, B. D., Papandreou, G., Narayan, P., Leon, M. B., et al. (2001) · Circulation · doi:10.1161/hc3601.093987 · Cited by 708
Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy
Wever, D. J., Veldhuizen, A. G., Sanders, M. M., Schakenraad, J. M., & van Horn, J. R. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00041-0 · Cited by 373
Fürst, W., & Banerjee, A. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.11.054 · Cited by 295
Attachment and proliferation of osteoblasts and fibroblasts on biomaterials for orthopaedic use
Hunter, A., Archer, C. W., Walker, P. S., & Blunn, G. W. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93256-d · Cited by 274
Brash, J. L. (2000) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856200744237 · Cited by 201 · cited 1×
“…of this healing process can have profound implications on the success of a device and can depend on material properties such as texture, crystallinity, wettability, surface chemistry, cytotoxic leachables, and degradation products (Andrade et al., 1987; Brash, 2000; Helmus and Tweden, 1995).”
Background
Cited by
Oxidized Alginate-Based Hydrogels for Tissue Engineering Applications: A Review
Reakasame, S., & Boccaccini, A. R. (2018) · Biomacromolecules · doi:10.1021/acs.biomac.7b01331 · Cited by 408
Zhang, J., Rector, J., Lin, J. Q., Young, J. H., Sans, M., Katta, N., Giese, N., Yu, W., Nagi, C., Suliburk, J., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aan3968 · Cited by 406
Biological responses to physicochemical properties of biomaterial surface
Rahmati, M., Silva, E. A., Reseland, J. E., A. Heyward, C., & Haugen, H. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00103a · Cited by 391
Arifin, A., Sulong, A. B., Muhamad, N., Syarif, J., & Ramli, M. I. (2014) · Materials & Design · doi:10.1016/j.matdes.2013.09.045 · Cited by 349
Nanoporous inorganic membranes or coatings for sustained drug delivery in implantable devices
Gultepe, E., Nagesha, D., Sridhar, S., & Amiji, M. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.003 · Cited by 304
Biocompatibility assessment of biomaterials used in orthopedic devices: An overview (Review)
Huzum, B., Puha, B., Necoara, R., Gheorghevici, S., Puha, G., Filip, A., Sirbu, P., & Alexa, O. (2021) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2021.10750 · Cited by 253
Wancket, L. M. (2015) · Veterinary Pathology · doi:10.1177/0300985815593124 · Cited by 226
“systemic effects (ie, immune reaction to osteoinductive material).(30) Biocompatible implants (and any breakdown or leachable derivatives) should be nontoxic, nonthrombogenic, noncarcinogenic, nonantigenic, and nonmutagenic.”
BackgroundBiomedical applications of polyethylene
Paxton, N. C., Allenby, M. C., Lewis, P. M., & Woodruff, M. A. (2019) · European Polymer Journal · doi:10.1016/j.eurpolymj.2019.05.037 · Cited by 215
Mariello, M., Kim, K., Wu, K., Lacour, S. P., & Leterrier, Y. (2022) · Advanced Materials · doi:10.1002/adma.202201129 · Cited by 195
Saeed, K., McLaren, A. C., Schwarz, E. M., Antoci, V., Arnold, W. V., Chen, A. F., Clauss, M., Esteban, J., Gant, V., Hendershot, E., et al. (2019) · Journal of Orthopaedic Research · doi:10.1002/jor.24229 · Cited by 181
Review of zirconia-based bioceramic: Surface modification and cellular response
Soon, G., Pingguan-Murphy, B., Lai, K. W., & Akbar, S. A. (2016) · Ceramics International · doi:10.1016/j.ceramint.2016.05.077 · Cited by 180
Drug-releasing implants: current progress, challenges and perspectives
Santos, A., Sinn Aw, M., Bariana, M., Kumeria, T., Wang, Y., & Losic, D. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00548a · Cited by 158
Greaves, P. (2012) · Histopathology of Preclinical Toxicity Studies · doi:10.1016/b978-0-444-53856-7.00002-6 · Cited by 5
Metadata
- Authors
- Helmus, M. N., Gibbons, D. F., & Cebon, D.
- Venue
- Toxicologic Pathology
- Publisher
- SAGE Publications
- Published
- 2008-01
- Volume
- 36
- Issue
- 1
- Pages
- 70-80
- ISSN
- 0192-6233 (ISSN-L)
- 1533-1601
- OpenAlex
- W2142960025
- Cited by
- 170
- References
- 42
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.