Sensitivity, Specificity, and Posttest Probability of Parotid Fine‐Needle Aspiration: A Systematic Review and Meta‐analysis
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Objectives: (1) To analyze the sensitivity and specificity of fine‐needle aspiration (FNA) in distinguishing benign from malignant parotid disease. (2) To determine the anticipated posttest probability of malignancy and probability of nondiagnostic and indeterminate cytology with parotid FNA. Data Sources: Independently corroborated computerized searches of PubMed, Embase, and Cochrane Central Register were performed. These were supplemented with manual searches and input from content experts. Review Methods: Inclusion/exclusion criteria specified diagnosis of parotid mass, intervention with both FNA and surgical excision, and enumeration of both cytologic and surgical histopathologic results. The primary outcomes were sensitivity, specificity, and posttest probability of malignancy. Heterogeneity was evaluated with the I2 statistic. Meta‐analysis was performed via a 2‐level mixed logistic regression model. Bayesian nomograms were plotted via pooled likelihood ratios. Results: The systematic review yielded 70 criterion‐meeting studies, 63 of which contained data that allowed for computation of numerical outcomes (n = 5647 patients; level 2a) and consideration of meta‐analysis. Subgroup analyses were performed in studies that were prospective, involved consecutive patients, described the FNA technique utilized, and used ultrasound guidance. The I2 point estimate was >70% for all analyses, except within prospectively obtained and ultrasound‐guided results. Among the prospective subgroup, the pooled analysis demonstrated a sensitivity of 0.882 (95% confidence interval [95% CI], 0.509‐0.982) and a specificity of 0.995 (95% CI, 0.960‐0.999). The probabilities of nondiagnostic and indeterminate cytology were 0.053 (95% CI, 0.030‐0.075) and 0.147 (95% CI, 0.106‐0.188), respectively. Conclusion: FNA has moderate sensitivity and high specificity in differentiating malignant from benign parotid lesions. Considerable heterogeneity is present among studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552 · cited 1×
“This was accomplished through a random effects model with weights based on the DerSimonian and Laird method.(16) Calculations were performed in Stata 13.”
MethodProposals for the classification of the myelodysplastic syndromes
Bennett, J. M., Catovsky, D., Daniel, M. T., Flandrin, G., Galton, D. A. G., Gralnick, H. R., & Sultan, C. (1982) · British Journal of Haematology · doi:10.1111/j.1365-2141.1982.tb08475.x · Cited by 3,627
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369 · cited 1×
“Sensitivity and specificity data were calculated according to standard formulas for dichotomously categorized outcomes.(17-19) Nondiagnostic and indeterminate results were excluded from the pooled analysis of sensitivity and specificity, as they were unable to be clearly designated as either benign or malignant and su…”
MethodHarris, N. L., Jaffe, E. S., Diebold, J., Flandrin, G., Muller-Hermelink, H. K., Vardiman, J., Lister, T. A., & Bloomfield, C. D. (1999) · Journal of Clinical Oncology · doi:10.1200/jco.1999.17.12.3835 · Cited by 3,267
Anderson, D., Rodger, M., Ginsberg, J., Kearon, C., Gent, M., Turpie, A., Bormanis, J., Weitz, J., Chamberlain, M., Bowie, D., et al. (2000) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613830 · Cited by 1,659
A hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505 · cited 1×
“The sensitivity and specificity from the individual studies were used to construct a receiver operating characteristic curve via a hierarchical regression model.(20) Bayesian nomograms were plotted with pooled LRs to determine of posttest probability of malignancy.”
MethodProposals for the classification of the myelodysplastic syndromes
Bennett, J. M., Catovsky, D., Daniel, M., Flandrin, G., Galton, D. A. G., Gralnick, H. R., & Sultan, C. (1982) · British Journal of Haematology · doi:10.1111/j.1365-2141.1982.tb02771.x · Cited by 1,275
Baloch, Z. W., LiVolsi, V. A., Asa, S. L., Rosai, J., Merino, M. J., Randolph, G., Vielh, P., DeMay, R. M., Sidawy, M. K., & Frable, W. J. (2008) · Diagnostic Cytopathology · doi:10.1002/dc.20830 · Cited by 880 · cited 1×
“This is in contrast to, for example, the Bethesda system for reporting thyroid cytopathology.(68) Similar to those of the parotid gland, FNAs of the thyroid have been associated with variability in the reporting of intermediate results.”
ResultChu, H., & Cole, S. R. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2006.06.011 · Cited by 708 · cited 1×
“Sensitivity and specificity data were calculated according to standard formulas for dichotomously categorized outcomes.(17-19) Nondiagnostic and indeterminate results were excluded from the pooled analysis of sensitivity and specificity, as they were unable to be clearly designated as either benign or malignant and su…”
MethodSchmidt, R. L., Hall, B. J., Wilson, A. R., & Layfield, L. J. (2011) · American Journal of Clinical Pathology · doi:10.1309/ajcpoie0cznat6sq · Cited by 362
Parotid tumors: a 10-year experience
Lin, C. C., Tsai, M.-H., Huang, C.-C., Hua, C.-H., Tseng, H.-C., & Huang, S.-T. (2008) · American Journal of Otolaryngology · doi:10.1016/j.amjoto.2007.03.002 · Cited by 128 · cited 3×
“(1) the study examined adults and/or children presenting with clinically or radiographically identified parotid masses who subsequently underwent parotidectomy; (2) FNA was performed prior to surgery via palpation or ultrasound guidance; (3) the cytopathology results from the FNA as well as the histopathology results…”
BackgroundThe risk of tumoral seeding in needle biopsies.
Roussel, F., Dalion, J., & Benozio, M. (1989) · PubMed · Cited by 108
Witt, B. L., & Schmidt, R. L. (2013) · The Laryngoscope · doi:10.1002/lary.24339 · Cited by 107 · cited 2×
“2%, respectively.(72) Our analysis suggests that standard FNA has a lower sensitivity versus that of USCB; however, the specificity of the 2 techniques is comparable.”
BackgroundResultFine-needle aspiration cytology in the management of parotid masses: Evaluation of 249 patients
Fakhry, N., Antonini, F., Michel, J., Pénicaud, M., Mancini, J., Lagier, A., Santini, L., Turner, F., Chrestian, M.-A., Zanaret, M., et al. (2012) · European Annals of Otorhinolaryngology Head and Neck Diseases · doi:10.1016/j.anorl.2011.10.008 · Cited by 74 · cited 4×
“In 12 studies, however, suspicious FNA findings were grouped with those that were clearly malignant, and the numbers associated with each were not explicitly reported.(21,33,49,57-65)”
InfluentialFine-needle aspiration biopsy of head and neck lesions
Schelkun, P. M., & Grundy, W. G. (1991) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/0278-2391(91)90216-9 · Cited by 68
Malignant tumours of the parotid gland: a 12-year review
Malata, C. M., Camilleri, I. G., McLean, N. R., Piggot, T. A., Kelly, C. G., Chippindale, A. J., & Soames, J. V. (1997) · British Journal of Plastic Surgery · doi:10.1016/s0007-1226(97)90505-1 · Cited by 67 · cited 3×
“…j Javadi et al (2012)78 h Jeong et al (2013)46 h j j Kamal et al (1997)88 h Lee et al (2013)89 h h Lim et al (2007)63 h h Lurie et al (2002)90 j j j Malata et al (1997)31 h h Abbreviation: FNA, fine-needle aspiration. aA black square, j, indicates that the study was prospective, involved…”
InfluentialFine‐needle aspiration of parotid gland lesions
Weinberger, M. S., Rosenberg, W. W., Meurer, W. T., & Robbins, K. T. (1992) · Head & Neck · doi:10.1002/hed.2880140611 · Cited by 60 · cited 1×
“…et al (1999)94 j Tew et al (1997)95 h Tsai et al (2002)96 h h Upton et al (2007)30 h h van Lierop et al (2007)97 h h Veder et al (2010)23 j j h Weinberger et al (1992)44 h j Wyss et al (2013)27 h h Yerli et al (2010)35 j j Zafar et al (1997)54 j Zbaren et al (2008)65 h j Zurrida et al…”
Am, C., Corina, L., Sergi, B., Fadda, G. L., & Paludetti, G. (2003) · PubMed · Cited by 37
Parotid fine-needle aspiration: A cytologic study of pediatric lesions
Mathew, S., & Ali, S. Z. (1997) · Diagnostic Cytopathology · doi:10.1002/(sici)1097-0339(199707)17:1<8::aid-dc2>3.0.co;2-e · Cited by 35 · cited 1×
“Finally, 4 studies presented the raw data and did not calculate sensitivity or specificity.(25,28,55,56) Our a priori definition of an indeterminate result included any that were not definitively benign or malignant or nondiagnostic, including results that were ‘‘suspicious’’ for malignancy.”
BackgroundEvidence‐Based Medicine in Otolaryngology Part 4: Everyday Probabilities—Nonbinary Diagnostic Tests
Shin, J. J., Stinnett, S. S., & Randolph, G. W. (2013) · Otolaryngology · doi:10.1177/0194599813491070 · Cited by 13
Self-citation
Metadata
- Authors
- Liu, C. C., Jethwa, A. R., Khariwala, S. S., Johnson, J., & Shin, J. J.
- Venue
- Otolaryngology–Head and Neck Surgery
- Publisher
- Wiley
- Published
- 2015-10
- Volume
- 154
- Issue
- 1
- Pages
- 9-23
- ISSN
- 0161-6439 (ISSN-L)
- 0194-5998
- 1097-6817
- OpenAlex
- W2326157138
- Cited by
- 191
- References
- 20
- FWCI
- 6.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.