Transoral Robotic Surgery for Obstructive Sleep Apnea: A Systematic Review and Meta‐Analysis

Justin, Grant A., Chang, Edward T., Camacho, Macario, Brietzke, Scott E. · 2016 · Otolaryngology–Head and Neck Surgery

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

Objective: To perform a systematic review of the international biomedical literature evaluating the effectiveness, complications, and safety of transoral robotic surgery (TORS) for the treatment of obstructive sleep apnea (OSA). Data Sources: PubMed/MEDLINE, Embase, and EMB Reviews databases were searched up to November 27, 2015. Review Methods: Two authors systematically and independently searched for articles on TORS for the treatment of OSA in adults that reported either outcomes for the apnea‐hypopnea index (AHI), lowest oxygen saturation percentage (LSAT) or changes in the Epworth Sleepiness Scale (ESS), and/or rates and types of complications associated with the operation. Results: In total, 181 records were identified and 16 articles met inclusion criteria. Transoral robotic surgery was almost always combined with other sleep surgery procedures. The summary estimate of the decrease in AHI using TORS as part of a multilevel surgical approach was 24.0 (95% confidence interval [CI], 22.1‐25.8; P <. 001, I2 = 99%). The summary estimate of a decrease in ESS score was 7.2 (95% CI, 6.6‐7.7; P <. 001, I2 = 99%) and of the overall surgical “success” (defined as AHI <20 and 50% reduction) was 48.2% (95% CI, 38.8%‐57.7%; P <. 001, I2 = 99%). Three large studies reported on their total complication rates with an average of 22.3% (range, 20.5%‐24.7%). Conclusions: The initial results for the use of TORS as part of a multilevel surgical approach for OSA are promising for select patients. However, the cost and morbidity may be greater than with other techniques offsetting its advantages in visualization and precision. More prospective studies are needed to determine the optimal role of this tool.

Overview

Integrity signals

Registry

Crossref · 10.1177/0194599816630962

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. OCEBM Levels of Evidence Working Group.The Oxford levels of evidence 2.http://www.cebm.net/index.aspx?o=5653. Accessed December 14 2015.

Cited by

See all 60

Metadata

Authors
Justin, G. A., Chang, E. T., Camacho, M., & Brietzke, S. E.
Affiliations
  • Uniformed Services University of the Health Sciences (US)
  • Tripler Army Medical Center (US)
  • Walter Reed National Military Medical Center (US)
Corresponding author
Justin, Grant A.
Venue
Otolaryngology–Head and Neck Surgery
Publisher
Wiley
Published
2016-03
Volume
154
Issue
5
Pages
835-846
ISSN
  • 0161-6439 (ISSN-L)
  • 0194-5998
  • 1097-6817
OpenAlex
W2288409141
Cited by
60
References
38
Citations by year
2026: 5 · 2025: 6 · 2024: 6 · 2023: 5 · 2022: 5 · 2021: 6 · 2020: 10 · 2019: 3 · 2018: 7 · 2017: 6 · 2016: 1
FWCI
0.67
Type
journal article
Language
en
Open access
closed
Locations
  • Otolaryngology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
  • Health Sciences › Medicine › Surgery › Nasal Surgery and Airway Studies
Keywords
transoral robotic surgery, obstructive sleep apnea, apnea-hypopnea index, Epworth Sleepiness Scale, surgical complications, surgical success
MeSH terms
Humans, Postoperative Complications, Outcome Assessment, Health Care, Sleep Apnea, Obstructive, Robotic Surgical Procedures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.