The EpiDerm Test Protocol for the Upcoming ECVAM Validation Study on In Vitro Skin Irritation Tests — An Assessment of the Performance of the Optimised Test
The DOI matches its Crossref record.
Abstract
During the past decade, several validation studies have been conducted on in vitro methods for discriminating between skin irritating and non-irritating chemicals. The reconstructed human skin models, EpiDerm and EPISKIN, provided the most promising results. Based on experience of the similar performance of the two skin models, it was suggested that a common test protocol and prediction model should be developed for the prediction of skin irritation potential with the two models. When the EPISKIN protocol was applied with the EpiDerm model, an acceptable specificity (80%) was achieved, whereas the sensitivity (60%) was low. In 2003, the EPISKIN protocol was further refined by extending the post-incubation period following exposure to test chemicals. This extension and additional technical improvements to the EpiDerm protocol were evaluated with 19 chemicals from the prevalidation study. With the new test design, high sensitivity (80%) and specificity (78%) were obtained. The statistical probability for correct classifications was high, so the test was considered to be ready for formal validation. However, since test optimisation had been conducted with the same test chemicals as were used in the ECVAM prevalidation study, it was decided that the optimisation of the protocol had to be verified with a new set of chemicals. Thus, in the current study, 26 additional chemicals (10 rabbit irritants and 16 non-irritants), which had previously been selected and tested by L'ORΈAL with EPISKIN, were evaluated in three independent experiments with EpiDerm. With this unbalanced testing set, a specificity of 94%, and a sensitivity of 60% were obtained, while the positive and negative predictivity and accuracy remained almost unchanged (around 80%) in comparison to the in vivo rabbit data. Overall, 45 chemicals (20 irritants and 25 non-irritants) were tested according to the final protocol. The resulting high positive (82%) and negative predictive values (79%) confirmed the reliability (accuracy of 80%) of the improved test protocol of the EpiDerm model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Niehues, H., Bouwstra, J. A., El Ghalbzouri, A., Brandner, J. M., Zeeuwen, P. L. J. M., & van den Bogaard, E. H. (2018) · Experimental Dermatology · doi:10.1111/exd.13531 · Cited by 210
Assessment of Skin Toxicity in an in Vitro Reconstituted Human Epidermis Model Using Deep Learning
Hu, F., Santagostino, S. F., Danilenko, D. M., Tseng, M., Brumm, J., Zehnder, P., & Wu, K. C. (2022) · The American Journal of Pathology · doi:10.1016/j.ajpath.2021.12.007 · Cited by 13
Diegel, K. L., Danilenko, D. M., & Wojcinski, Z. W. (2013) · Haschek and Rousseaux's Handbook of Toxicologic Pathology · doi:10.1016/b978-0-12-415759-0.00055-8 · Cited by 6
Metadata
- Authors
- Kandárová, H., Liebsch, M., Gerner, I., Schmidt, E., Genschow, E., Traue, D., & Spielmann, H.
- Venue
- Alternatives to Laboratory Animals
- Publisher
- SAGE Publications
- Published
- 2005-08
- Volume
- 33
- Issue
- 4
- Pages
- 351-367
- ISSN
- 0261-1929 (ISSN-L)
- 2632-3559
- OpenAlex
- W171361765
- Cited by
- 68
- References
- 0
- FWCI
- 11.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The EpiDerm Test Protocol for the Upcoming ECVAM Validation Study on In Vitro Skin Irritation Tests — An Assessment of the Performance of the Optimised Test. https://app.cochat.ai/papers/10.1177/026119290503300408
- The paper
- Kandárová, H., Liebsch, M., Gerner, I., Schmidt, E., Genschow, E., Traue, D., & Spielmann, H. (2005). The EpiDerm Test Protocol for the Upcoming ECVAM Validation Study on In Vitro Skin Irritation Tests — An Assessment of the Performance of the Optimised Test. Alternatives to Laboratory Animals. https://doi.org/10.1177/026119290503300408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.