Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Kinetics and 28-day test–retest repeatability and reproducibility of [ 11 C]UCB-J PET brain imaging

Open access

Abstract

[ 11 C]UCB-J is a novel radioligand that binds to synaptic vesicle glycoprotein 2A (SV2A). The main objective of this study was to determine the 28-day test–retest repeatability (TRT) of quantitative [ 11 C]UCB-J brain positron emission tomography (PET) imaging in Alzheimer’s disease (AD) patients and healthy controls (HCs). Nine HCs and eight AD patients underwent two 60 min dynamic [ 11 C]UCB-J PET scans with arterial sampling with an interval of 28 days. The optimal tracer kinetic model was assessed using the Akaike criteria (AIC). Micro-/macro-parameters such as tracer delivery (K 1 ) and volume of distribution (V T ) were estimated using the optimal model. Data were also analysed for simplified reference tissue model (SRTM) with centrum semi-ovale (white matter) as reference region. Based on AIC, both 1T2k_V B and 2T4k_V B described the [ 11 C]UCB-J kinetics equally well. Analysis showed that whole-brain grey matter TRT for V T , DVR and SRTM BP ND were –2.2% ± 8.5, 0.4% ± 12.0 and –8.0% ± 10.2, averaged over all subjects. [ 11 C]UCB-J kinetics can be well described by a 1T2k_V B model, and a 60 min scan duration was sufficient to obtain reliable estimates for both plasma input and reference tissue models. TRT for V T , DVR and BP ND was <15% (1SD) averaged over all subjects and indicates adequate quantitative repeatability of [ 11 C]UCB-J PET.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0271678x20964248

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. [11C]UCB-J metabolite fractions (mean ± SD) in arterial plasma at different time points.
Figure 1. [11C]UCB-J metabolite fractions (mean ± SD) in arterial plasma at different time points.CC BY · PubMed Central
Figure 2. Comparison of K1 and VT derived from 1T2k_VB model against K1 and VT derived from 2T4k_VB model apart for (a), (c) AD patients and (b), (d) HCs using Amsterdam UMC data. LOI: line of identity.
Figure 2. Comparison of K1 and VT derived from 1T2k_VB model against K1 and VT derived from 2T4k_VB model apart for (a), (c) AD patients and (b), (d) HCs using Amsterdam UMC data. LOI: line of identity.CC BY · PubMed Central
Figure 3. Effect of scan duration reduction on (a), (b), (c) VT and (d), (e), (f) K1 estimations using Amsterdam UMC data.
Figure 3. Effect of scan duration reduction on (a), (b), (c) VT and (d), (e), (f) K1 estimations using Amsterdam UMC data.CC BY · PubMed Central
Figure 4. Comparison of SRTM-derived BPND against plasma input DVR for (a) AD patients and (b) HCs using Amsterdam UMC data. LOI: line of identity.
Figure 4. Comparison of SRTM-derived BPND against plasma input DVR for (a) AD patients and (b) HCs using Amsterdam UMC data. LOI: line of identity.CC BY · PubMed Central
Figure 5. (a), (c) Whole brain (grey matter) VT and plasma input DVR values derived from 1T2k_VB model are displayed for the test and retest scan apart for HCs and AD patients; (b), (d) TRT for whole brain (grey matter) VT and plasma input DVR values are displayed apart for HCs and AD patients using Amsterdam UMC data. Error bars indicate mean ± SD. **implies p < 0.01.
Figure 5. (a), (c) Whole brain (grey matter) VT and plasma input DVR values derived from 1T2k_VB model are displayed for the test and retest scan apart for HCs and AD patients; (b), (d) TRT for whole brain (grey matter) VT and plasma input DVR values are displayed apart for HCs and AD patients using Amsterdam UMC data. Error bars indicate mean ± SD. **implies p < 0.01.CC BY · PubMed Central
Figure 6. Bland Altman %TRT plots for VT, SRTM BPND and plasma input DVR obtained using 60 min PET data for (a), (c), (e) HCs and (b), (d), (f) AD patients using Amsterdam UMC data.
Figure 6. Bland Altman %TRT plots for VT, SRTM BPND and plasma input DVR obtained using 60 min PET data for (a), (c), (e) HCs and (b), (d), (f) AD patients using Amsterdam UMC data.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Research works printed but not linked: 1

  1. Kim JS, 2006, J Nucl Med, 47, 208

Cited by

See all 45

Metadata

Authors
Tuncel, H., Boellaard, R., Coomans, E. M., de Vries, E. F., Glaudemans, A. W., Feltes, P. K., García, D. V., Verfaillie, S. C., Wolters, E. E., Sweeney, S. P., Ryan, J. M., Ivarsson, M., Lynch, B. A., Schober, P., Scheltens, P., Schuit, R. C., Windhorst, A. D., De Deyn, P. P., van Berckel, B. N., & Golla, S. S.
Affiliations
  • Amsterdam Neuroscience (NL)
  • Department of Nuclear Medicine and Molecular Imaging, University Medical Center, University of Groningen, Groningen, The Netherlands
  • University Medical Center Groningen (NL)
  • Rodin Therapeutics (United States) (US)
  • Amsterdam University Medical Centers (NL)
  • Department of Neurology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
  • Department of Radiology & Nuclear Medicine, Amsterdam Neuroscience, Amsterdam UMC, Amsterdam, The Netherlands
Corresponding author
Tuncel, Hayel
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
2020-10-08
Volume
41
Issue
6
Pages
1338-1350
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W3092530164
Cited by
45
References
33
Citations by year
2026: 3 · 2025: 2 · 2024: 7 · 2023: 4 · 2022: 26 · 2021: 3
FWCI
6.02
Type
journal article
Language
en
Open access
Locations
  • Journal of Cerebral Blood Flow & Metabolism (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Amsterdam UMC (VU Amsterdam) - Institutional Repository (submittedVersion, other-oa)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion, cc-by)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Psychiatry and Mental health › Dementia and Cognitive Impairment Research
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Alzheimer's disease research and treatments
Keywords
[11C]UCB-J, SV2A, Alzheimer's disease, test-retest repeatability, reproducibility, tracer kinetics, simplified reference tissue model, volume of distribution, distribution volume ratio, binding potential, dynamic PET, arterial sampling, Akaike information criterion
MeSH terms
Aged, Aged, 80 and over, Alzheimer Disease, Female, Humans, Image Interpretation, Computer-Assisted, Kinetics, Male, Membrane Glycoproteins, Middle Aged, Nerve Tissue Proteins, Pyridines, Pyrrolidinones, Reproducibility of Results, Radiopharmaceuticals, Positron-Emission Tomography, Neuroimaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Kinetics and 28-day test–retest repeatability and reproducibility of [ 11 C]UCB-J PET brain imaging. https://app.cochat.ai/papers/10.1177/0271678x20964248
The paper
Tuncel, H., Boellaard, R., Coomans, E. M., de Vries, E. F., Glaudemans, A. W., Feltes, P. K., García, D. V., Verfaillie, S. C., Wolters, E. E., Sweeney, S. P., Ryan, J. M., Ivarsson, M., Lynch, B. A., Schober, P., Scheltens, P., Schuit, R. C., Windhorst, A. D., De Deyn, P. P., van Berckel, B. N., & Golla, S. S. (2021). Kinetics and 28-day test–retest repeatability and reproducibility of [ 11 C]UCB-J PET brain imaging. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1177/0271678x20964248

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.