Safety Evaluation Method of Design and Control for Human-Care Robots
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We propose the world's first general method of evaluating safety for human-care robots. In the case of a careless collision between a robot and a human, impact force and impact stress are chosen as evaluation measures, and a danger-index is defined to quantitatively evaluate the effectiveness of each safety strategy used for design and control. As a result, this proposed method allows us to assess the contribution of each safety strategy to the overall safety performance of a human-care robot. In addition, a new type of three-dimensional robot simulation system for danger evaluation is constructed on a PC. The system simplifies the danger evaluation of both the design and control of various types of human-care robots to quantify the effectiveness of various safety strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
International Organization for Standardization
(2011) · SpringerReference · doi:10.1007/springerreference_16847 · Cited by 12,534
Manipulability of Robotic Mechanisms
Yoshikawa, T. (1985) · The International Journal of Robotics Research · doi:10.1177/027836498500400201 · Cited by 2,582
Suita, K., Yamada, Y., Tsuchida, N., Imai, K., Ikeda, H., & SUGIMOTO, N. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1995.525724 · Cited by 146
Cited by
Bartneck, C., Kulić, D., Croft, E., & Zoghbi, S. (2009) · International Journal of Social Robotics · doi:10.1007/s12369-008-0001-3 · Cited by 3,193
“guarding zones [63, 64].”
An atlas of physical human–robot interaction
De Santis, A., Siciliano, B., De Luca, A., & Bicchi, A. (2008) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2007.03.003 · Cited by 826
Collision Detection and Safe Reaction with the DLR-III Lightweight Manipulator Arm
De Luca, A., Albu-Schaffer, A., Haddadin, S., & Hirzinger, G. (2006) · 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2006.282053 · Cited by 779
Bicchi, A., & Tonietti, G. (2004) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2004.1310939 · Cited by 654
Working Together: A Review on Safe Human-Robot Collaboration in Industrial Environments
Robla-Gomez, S., Becerra, V. M., Llata, J. R., Gonzalez-Sarabia, E., Torre-Ferrero, C., & Perez-Oria, J. (2017) · IEEE Access · doi:10.1109/access.2017.2773127 · Cited by 589
“The danger index, which is based on [97], was defined as the product of the distance, velocity and inertia factors, and it was estimated for the nearest point between each link and the human, activating a suitable evasive action when the index exceeds a pre-defined threshold.”
Background
Metadata
- Authors
- Ikuta, K., Ishii, H., & Nokata, M.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2003-05-01
- Volume
- 22
- Issue
- 5
- Pages
- 281-297
- ISSN
- 0278-3649 (ISSN-L)
- 0000-0000
- OpenAlex
- W2042846337
- Cited by
- 239
- References
- 4
- FWCI
- 8.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.