The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Modeling and Control of Untethered Biomicrorobots in a Fluidic Environment Using Electromagnetic Fields
Abstract
This paper investigates fundamental design, modeling, and control issues related to untethered biomedical microrobots guided inside the human body through external magnetic fields. Proposed areas of application for these microrobots include sensing, diagnosis, and surgical procedures in intraocular, cardiovascular, and inner-ear environments. A prototype microrobot and steering system are introduced. Fluid drag experiments performed on the prototype robot show that the 950 × 400 μ m elliptical shape has a spherical equivalent diameter of 477 μ m. Drag forces combined with saturation magnetization (5 × 10 5 A/m) of the prototype indicate that the required magnetic field gradients for application inside the vitreous humor and blood vessels are on the order of 0.7T/m.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weiss, J. N. (1998) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(98)00086-5 · Cited by 100
Cited by
OctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation
Kummer, M. P., Abbott, J. J., Kratochvil, B. E., Borer, R., Sengul, A., & Nelson, B. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2073030 · Cited by 1,161
Self-citationBiomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893
Abbott, J. J., Diller, E., & Petruska, A. J. (2020) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-081219-082713 · Cited by 355
A review of magnet systems for targeted drug delivery
Liu, Y.-L., Chen, D., Shang, P., & Yin, D.-C. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.03.031 · Cited by 298
Metadata
- Authors
- Yesin, K. B., Vollmers, K., & Nelson, B. J.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2006-05
- Volume
- 25
- Issue
- 5-6
- Pages
- 527-536
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2116813238
- Cited by
- 465
- References
- 1
- FWCI
- 20.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modeling and Control of Untethered Biomicrorobots in a Fluidic Environment Using Electromagnetic Fields. https://app.cochat.ai/papers/10.1177/0278364906065389
- The paper
- Yesin, K. B., Vollmers, K., & Nelson, B. J. (2006). Modeling and Control of Untethered Biomicrorobots in a Fluidic Environment Using Electromagnetic Fields. The International Journal of Robotics Research. https://doi.org/10.1177/0278364906065389
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.