The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Hybrid Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Abstract
The Berkeley Lower Extremity Exoskeleton is the first functional energetically autonomous load carrying human exoskeleton and was demonstrated at U.C. Berkeley, walking at the average speed of 0.9 m/s (2 mph) while carrying a 34 kg (75 lb) payload. The original published controller, called the BLEEX Sensitivity Amplification Controller, was based on positive feedback and was designed to increase the closed loop system sensitivity to its wearer’s forces and torques without any direct measurement from the wearer. This controller was successful at allowing natural and unobstructed load support for the pilot. This article presents an improved control scheme we call “hybrid” BLEEX control that adds robustness to changing BLEEX backpack payload. The walking gait cycle is divided into stance control and swing control phases. Position control is used for the BLEEX stance leg (including the torso and backpack) and a sensitivity amplification controller is used for the swing leg. The controller is also designed to smoothly transition between these two schemes as the pilot walks. With hybrid control, the controller does not require a good model of the BLEEX torso and payload, which is difficult to obtain and subject to change as payload is added and removed. As a tradeoff, the position control used in this method requires the human to wear seven inclinometers to measure human limb and torso angles. These additional sensors require careful design to securely fasten them to the human and increase the time to don and doff BLEEX.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
The development of Honda humanoid robot
Hirai, K., Hirose, M., Haikawa, Y., & Takenaka, T. (2002) · Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146) · doi:10.1109/robot.1998.677288 · Cited by 1,922
Stair ascent and descent at different inclinations
Riener, R., Rabuffetti, M., & Frigo, C. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00162-x · Cited by 744
The relation between force and velocity in human muscle
Wilkie, D. R. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004437 · Cited by 632
On the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Racine, J.-L., Huang, L., & Steger, R. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570790 · Cited by 594
Self-citationWoodson, W. E. (1981) · Cited by 589
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
Winters, J. M., & Stark, L. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325498 · Cited by 526 · cited 2×
“Many other more detailed models of H also exist (Wilkie 1950; Winters and Stark 1985 ), but are not necessary for this discussion.”
BackgroundHuman Robot Interaction via the Transfer of Power and Information Signals
Kazerooni, H. (1990) · IEEE Trans. · Cited by 362
Self-citationPower Assist System HAL-3 for Gait Disorder Person
Kawamoto, H., & Sankai, Y. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45491-8_43 · Cited by 346
Human-robot interaction via the transfer of power and information signals
Kazerooni, H. (1990) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.52555 · Cited by 338
Self-citationOn the mechanical design of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Zoss, A., Kazerooni, H., & Chu, A. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545453 · Cited by 305
Self-citationOn the Biomimetic Design of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Chu, A., Kazerooni, H., & Zoss, A. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570789 · Cited by 258 · cited 1×
“The overall concept of this lower extremity exoskeleton is that the human provides an intelligent control system for the exoskeleton while the exoskeleton actuators provide most of the strength necessary for walking [1,2].”
BackgroundSelf-citationPower assist method for HAL-3 estimating operator's intention based on motion information
Kawamoto, H., Kanbe, S., & Sankai, Y. (2004) · doi:10.1109/roman.2003.1251800 · Cited by 149
Makinson, B. J. (1971) · Defense Technical Information Center (DTIC) · doi:10.21236/ad0724797 · Cited by 142
Mosher, R. S. (1967) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/670088 · Cited by 142
Kazerooni, H., & Guo, J. (1993) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2899068 · Cited by 119
Self-citationThe dynamics and control of a haptic interface device
Kazerooni, H., & Her, M.-G. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.313096 · Cited by 115
Self-citationThe human power amplifier technology at the University of California, Berkeley
Kazerooni, H. (1996) · Robotics and Autonomous Systems · doi:10.1016/s0921-8890(96)00045-0 · Cited by 105
Self-citationDynamics and Control of Robotic Systems Worn by Humans
Kazerooni, H., & Mahoney, S. L. (1991) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2896421 · Cited by 91
Self-citationDriven gait orthosis to do locomotor training of paraplegic patients
Colombo, G., Jorg, M., & Dietz, V. (2002) · Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143) · doi:10.1109/iembs.2000.901556 · Cited by 72
Hybrid hydraulic-electric power unit for field and service robots
Amundson, K., Raade, J., Harding, N., & Kazerooni, H. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545452 · Cited by 55
Self-citationMonopropellant-Driven Free Piston Hydraulic Pump for Mobile Robotic Systems
McGee, T. G., Raade, J. W., & Kazerooni, H. (2004) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.1649972 · Cited by 44
Self-citationCase Study on Haptic Devices: Human-Induced Instability in Powered Hand Controllers
Kazerooni, H., & Snyder, T. J. (1995) · Journal of Guidance Control and Dynamics · doi:10.2514/3.56664 · Cited by 40
Self-citationAnalysis and Design of a Novel Hydraulic Power Source for Mobile Robots
Raade, J. W., & Kazerooni, H. (2005) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2005.850394 · Cited by 34
Self-citationHigh-speed communication network for controls with the application on the exoskeleton
Kim, S., Anwar, G., & Kazerooni, H. (2004) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2004.1383630 · Cited by 27
Self-citationPRELIMINARY DESIGN FOR THE SHOULDERS AND ARMS OF A POWERED EXOSKELETAL STRUCTURE.
Mizen, N. J. (1965) · Defense Technical Information Center (DTIC) · Cited by 12
Analysis and design of a novel power supply for mobile robots
Raade, J. W., Kazerooni, H., & McGee, T. G. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1302496 · Cited by 11
Self-citationHigh Speed Ring-Based Distributed Networked Control System for Real-Time Multivariable Applications
Kim, S., & Kazerooni, H. (2004) · doi:10.1115/imece2004-60064 · Cited by 10
Self-citation
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“overloading/saturating the actuator [137,171,215], failure of an undera ctuated system to achieve its desired state, power failures due to a loss of power to the actuator or to the c ntroller [137,232], and controller failures due to software bugs or overloaded computational res ources [60].”
BackgroundMethodHuman-in-the-loop optimization of exoskeleton assistance during walking
Zhang, J., Fiers, P., Witte, K. A., Jackson, R. W., Poggensee, K. L., Atkeson, C. G., & Collins, S. H. (2017) · Science · doi:10.1126/science.aal5054 · Cited by 1,011
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
Recent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“For example, BLEEX is controlled with a hybrid position and force controller, which is only based on the motion data measured from the exoskeleton [66].”
MethodIntention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474
Metadata
- Authors
- Kazerooni, H., Steger, R., & Huang, L.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2006-05
- Volume
- 25
- Issue
- 5-6
- Pages
- 561-573
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2070054839
- Cited by
- 382
- References
- 29
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.