Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 255

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Design, Control and Performance of RiceWrist:A Force Feedback Wrist Exoskeleton for Rehabilitation and Training

Gupta, Abhishek, O'Malley, Marcia K., Patoglu, Volkan, Burgar, Charles · 2008 · The International Journal of Robotics Research

Abstract

This paper presents the design, control and performance of a high fidelity four degree-of-freedom wrist exoskeleton robot, RiceWrist, for training and rehabilitation. The RiceWrist is intended to provide kinesthetic feedback during the training of motor skills or rehabilitation of reaching movements. Motivation for such applications is based on findings that show robot-assisted physical therapy aids in the rehabilitation process following neurological injuries. The exoskeleton device accommodates forearm supination and pronation, wrist flexion and extension and radial and ulnar deviation in a compact parallel mechanism design with low friction, zero backlash and high stiffness. As compared to other exoskeleton devices, the RiceWrist allows easy measurement of human joint angles and independent kinesthetic feedback to individual human joints. In this paper, joint-space as well as task-space position controllers and an impedance-based force controller for the device are presented. The kinematic performance of the device is characterized in terms of its workspace, singularities, manipulability, backlash and backdrivability. The dynamic performance of RiceWrist is characterized in terms of motor torque output, joint friction, step responses, behavior under closed loop set-point and trajectory tracking control and display of virtual walls. The device is singularity-free, encompasses most of the natural workspace of the human joints and exhibits low friction, zero-backlash and high manipulability, which are kinematic properties that characterize a high-quality impedance display device. In addition, the device displays fast, accurate response under position control that matches human actuation bandwidth and the capability to display sufficiently hard contact with little coupling between controlled degrees-of-freedom.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0278364907084261

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 255

Metadata

Authors
Gupta, A., O'Malley, M. K., Patoglu, V., & Burgar, C.
Venue
The International Journal of Robotics Research
Published
2008-02
Volume
27
Issue
2
Pages
233-251
ISSN
  • 0278-3649 (ISSN-L)
  • 1741-3176
OpenAlex
W2030770202
Cited by
255
References
33
FWCI
9.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design, Control and Performance of RiceWrist:A Force Feedback Wrist Exoskeleton for Rehabilitation and Training. https://app.cochat.ai/papers/10.1177/0278364907084261
The paper
Gupta, A., O'Malley, M. K., Patoglu, V., & Burgar, C. (2008). Design, Control and Performance of RiceWrist:A Force Feedback Wrist Exoskeleton for Rehabilitation and Training. The International Journal of Robotics Research. https://doi.org/10.1177/0278364907084261

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.