Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 211

The DOI matches its Crossref record.

Small, Fast, and Under Control: Wireless Resonant Magnetic Micro-agents

Frutiger, Dominic R., Vollmers, Karl, Kratochvil, Bradley E., Nelson, Bradley J. · 2010 · The International Journal of Robotics Research

Abstract

Primary challenges in the building of untethered submillimeter sized robots include propulsion methods, power supply, and control. We present a novel type of microrobot called MagMite that utilizes a new class of wireless resonant magnetic micro-actuator that accomplishes all three tasks. The term MagMite is derived from Magnetic Mite —a tribute to the underlying magnetic propulsion principle and the micro-scale dimensions of the robot. The device harvests magnetic energy from the environment and effectively transforms it into inertia-and impact-driven mechanical force while being fully controllable. It can be powered and controlled with oscillating fields in the kilohertz range and strengths as low as 2 mT, which is only roughly 50 times the average Earth magnetic field. These microrobotic agents with dimensions less than 300 μm × 300 μm × 70 μm and a total mass of 30—50 μg are capable of moving forward, backward and turning in place while reaching controllable speeds in excess of 12.5 mm s—1 or 42 times the robot’s body length per second. The robots produce enough force to push micro-objects of similar sizes and can be visually servoed through a maze in a fully automated fashion. The prototype devices exhibit an overall degree of flexibility, controllability, and performance unmatched by other microrobots reported in the literature. The robustness of the MagMites leads to high experimental repeatability, which in turn enabled us to successfully compete in the RoboCup 2007 and 2009 Nanogram competitions. In this work it is demonstrated how the robots exhibit a plethora of driving behaviors, how they can operate on a host of unstructured surfaces under both dry and wet conditions, and how they can accomplish fully automated micromanipulation tasks. Various micro-objects ranging from beads to biological entities have been successfully manipulated. To the same end, multi-agent studies have shown great promise to be used in cooperative tasks.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0278364909353351

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 211

Metadata

Authors
Frutiger, D. R., Vollmers, K., Kratochvil, B. E., & Nelson, B. J.
Venue
The International Journal of Robotics Research
Published
2009-11-13
Volume
29
Issue
5
Pages
613-636
ISSN
  • 0278-3649 (ISSN-L)
  • 1741-3176
OpenAlex
W2165032710
Cited by
211
References
0
FWCI
12.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Small, Fast, and Under Control: Wireless Resonant Magnetic Micro-agents. https://app.cochat.ai/papers/10.1177/0278364909353351
The paper
Frutiger, D. R., Vollmers, K., Kratochvil, B. E., & Nelson, B. J. (2010). Small, Fast, and Under Control: Wireless Resonant Magnetic Micro-agents. The International Journal of Robotics Research. https://doi.org/10.1177/0278364909353351

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.