Equilibrium Conformations of Concentric-tube Continuum Robots
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Robots consisting of several concentric, preshaped, elastic tubes can work dexterously in narrow, constrained, and/or winding spaces, as are commonly found in minimally invasive surgery. Previous models of these “active cannulas” assume piecewise constant precurvature of component tubes and neglect torsion in curved sections of the device. In this paper we develop a new coordinate-free energy formulation that accounts for general preshaping of an arbitrary number of component tubes, and which explicitly includes both bending and torsion throughout the device. We show that previously reported models are special cases of our formulation, and then explore in detail the implications of torsional flexibility for the special case of two tubes. Experiments demonstrate that this framework is more descriptive of physical prototype behavior than previous models1 it reduces model prediction error by 82% over the calibrated bending-only model, and 17% over the calibrated transmissional torsion model in a set of experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Introduction to Robotic Manipulation
Murray, R. M., Li, Z., & Sastry, S. S. (2017) · CRC Press eBooks · doi:10.1201/9781315136370 · Cited by 6,694 · cited 1×
“Substituting before applying Euler– Lagrange is equivalent to assuming that is a holonomic constraint (Murray et al. 1994).”
MethodLeast-Squares Fitting of Two 3-D Point Sets
Arun, K. S., Huang, T. S., & Blostein, S. D. (1987) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1987.4767965 · Cited by 3,952 · cited 5×
“θ̇0 − (θ0 − α1 + α2) G1J1 +G2J2 G1J1D2 +G2J2D1 = 0, (46)”
MethodInfluentialA Mathmematical Introduction to Robotic Manipulation
Murray, R. M., Li, Z., & Sastry, S. (1994) · Cited by 2,676
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297 · cited 1×
“…arcs leads to very convenient kinematic formulations that have been widely exploited in prior work (e.g. Webster et al. (2009), Furusho et al. (2006), Sears and Dupont (2006), etc., see also Webster and Jones (2010) for an overview of piecewise constant curvature kinematics for continuum robots).”
BackgroundSelf-citation2013 IEEE International Conference on Robotics and Automation
(2013) · doi:10.1109/icra19839.2013 · Cited by 2,025
Nonlinear Problems of Elasticity
(2005) · Applied Mathematical Sciences · doi:10.1007/0-387-27649-1 · Cited by 1,670
Hannan, M. W., & Walker, I. D. (2003) · Journal of Robotic Systems · doi:10.1002/rob.10070 · Cited by 737 · cited 2×
“We show that previously reported models are special cases of our formulation, and then explore in detail the implications of torsional flexibility for the special case of two tubes.”
BackgroundMethodBergou, M., Wardetzky, M., Robinson, S., Audoly, B., & Grinspun, E. (2008) · ACM Transactions on Graphics · doi:10.1145/1360612.1360662 · Cited by 664
Mechanics Modeling of Tendon-Driven Continuum Manipulators
Camarillo, D. B., Milne, C. F., Carlson, C. R., Zinn, M. R., & Salisbury, J. K. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2002311 · Cited by 655 · cited 6×
“0 [ω(s)− ω∗(s)]TK(s)[ω(s)− ω∗(s)]ds, (4)”
BackgroundInfluentialNonholonomic Modeling of Needle Steering
Webster, R. J., Kim, J. S., Cowan, N. J., Chirikjian, G. S., & Okamura, A. M. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065388 · Cited by 633 · cited 11×
“Experiments demonstrate that this framework is more descriptive of physical prototype behavior than previous models it reduces model prediction error by 82% over the calibrated bending-only model, and”
BackgroundMethodResultInfluentialSelf-citation
Cited by
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Self-citationContinuum Robots for Medical Applications: A Survey
Burgner-Kahrs, J., Rucker, D. C., & Choset, H. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2489500 · Cited by 1,557
Self-citationSoft Robots Modeling: A Structured Overview
Armanini, C., Boyer, F., Mathew, A. T., Duriez, C., & Renda, F. (2023) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3231360 · Cited by 336
Continuum Robots for Medical Interventions
Dupont, P. E., Simaan, N., Choset, H., & Rucker, C. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3141338 · Cited by 307
A Telerobotic System for Transnasal Surgery
Burgner, J., Rucker, D. C., Gilbert, H. B., Swaney, P. J., Russell, P. T., Weaver, K. D., & Webster, R. J. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2265804 · Cited by 294
Self-citationModel-Less Feedback Control of Continuum Manipulators in Constrained Environments
Yip, M. C., & Camarillo, D. B. (2014) · IEEE Transactions on Robotics · doi:10.1109/tro.2014.2309194 · Cited by 262
Bio‐Inspired Soft Grippers Based on Impactive Gripping
Zhou, L., Ren, L., Chen, Y., Niu, S., Han, Z., & Ren, L. (2021) · Advanced Science · doi:10.1002/advs.202002017 · Cited by 205
Concentric Tube Robots: The State of the Art and Future Directions
Gilbert, H. B., Rucker, D. C., & Webster III, R. J. (2016) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-319-28872-7_15 · Cited by 197
“Experimental testing of the model has shown that with calibration, mean error in the prediction of tip position can be as low as 1% to 3% of overall arc length [62, 68, 28, 44].”
InfluentialSelf-citationMagnetic control of continuum devices
Edelmann, J., Petruska, A. J., & Nelson, B. J. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364916683443 · Cited by 194
“, 2014; Rucker and Webster, 2011), and concentric-tube devices (Rucker et al., 2010), but has yet to be applied to the control of magnetically tipped catheters.”
BackgroundSteerable catheters for minimally invasive surgery: a review and future directions
Hu, X., Chen, A., Luo, Y., Zhang, C., & Zhang, E. (2018) · Computer Assisted Surgery · doi:10.1080/24699322.2018.1526972 · Cited by 184
Alambeigi, F., Aghajani Pedram, S., Speyer, J. L., Rosen, J., Iordachita, I., Taylor, R. H., & Armand, M. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2946726 · Cited by 48
Metadata
- Authors
- Rucker, D. C., Webster, R. J., Chirikjian, G. S., & Cowan, N. J.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2010-04-01
- Volume
- 29
- Issue
- 10
- Pages
- 1263-1280
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2118997958
- Cited by
- 217
- References
- 22
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.