Six-degree-of-freedom magnetic actuation for wireless microrobotics
The DOI matches its Crossref record.
Abstract
Existing remotely actuated magnetic microrobots exhibit a maximum of only five-degree-of-freedom (DOF) actuation, as creation of a driving torque about the microrobot magnetization axis is not achievable. This lack of full orientation control limits the effectiveness of existing microrobots for precision tasks of object manipulation and orientation for advanced medical, biological and micromanufacturing applications. This paper presents a magnetic actuation method that allows remotely powered microrobots to achieve full six-DOF actuation by considering the case of a non-uniform magnetization profile within the microrobot body. This non-uniform magnetization allows for additional rigid-body torques to be induced from magnetic forces via a moment arm. A general analytical model presents the working principle for continuous and discrete magnetization profiles, which is applied to permanent or non-permanent (soft) magnet bodies. Several discrete-magnetization designs are also presented which possess reduced coupling between magnetic forces and induced rigid-body torques. Design guidelines are introduced which can be followed to ensure that a magnetic microrobot design is capable of six-DOF actuation. A simple permanent-magnet prototype is fabricated and used to quantitatively demonstrate the accuracy of the analytical model in a constrained-DOF environment and qualitatively for free motion in a viscous liquid three-dimensional environment. Results show that desired forces and torques can be created with high precision and limited parasitic actuation, allowing for full six-DOF actuation using limited feedback control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Small-scale soft-bodied robot with multimodal locomotion
Hu, W., Lum, G. Z., Mastrangeli, M., & Sitti, M. (2018) · Nature · doi:10.1038/nature25443 · Cited by 2,372
Self-citationSoft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Self-citationMagnetic Soft Materials and Robots
Kim, Y., & Zhao, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00481 · Cited by 873
Shape-programmable magnetic soft matter
Lum, G. Z., Ye, Z., Dong, X., Marvi, H., Erin, O., Hu, W., & Sitti, M. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1608193113 · Cited by 650
Self-citationSoft Actuators for Soft Robotic Applications: A Review
El-Atab, N., Mishra, R. B., Al-Modaf, F., Joharji, L., Alsharif, A. A., Alamoudi, H., Diaz, M., Qaiser, N., & Hussain, M. M. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000128 · Cited by 552
Pros and Cons: Magnetic versus Optical Microrobots
Sitti, M., & Wiersma, D. S. (2020) · Advanced Materials · doi:10.1002/adma.201906766 · Cited by 398
Self-citationMobile microrobots for bioengineering applications
Ceylan, H., Giltinan, J., Kozielski, K., & Sitti, M. (2017) · Lab on a Chip · doi:10.1039/c7lc00064b · Cited by 392
Self-citationMagnetic Actuation Systems for Miniature Robots: A Review
Yang, Z., & Zhang, L. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000082 · Cited by 388
Abbott, J. J., Diller, E., & Petruska, A. J. (2020) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-081219-082713 · Cited by 355
Self-citationMultifunctional magnetic soft composites: a review
Wu, S., Hu, W., Ze, Q., Sitti, M., & Zhao, R. (2020) · Multifunctional Materials · doi:10.1088/2399-7532/abcb0c · Cited by 307
Self-citationChallenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Robotic metamorphosis by origami exoskeletons
Miyashita, S., Guitron, S., Li, S., & Rus, D. (2017) · Science Robotics · doi:10.1126/scirobotics.aao4369 · Cited by 208
Metadata
- Authors
- Diller, E., Giltinan, J., Lum, G. Z., Ye, Z., & Sitti, M.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2015-06-04
- Volume
- 35
- Issue
- 1-3
- Pages
- 114-128
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W641642611
- Cited by
- 169
- References
- 0
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.