A grasp-based passivity signature for haptics-enabled human-robot interaction: Application to design of a new safety mechanism for robotic rehabilitation
The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
In this paper, the biomechanical capability of the human upper limb in absorbing physical interaction energy during human-robot interaction is analyzed. The outcome is a graphical map that can quantitatively correlate the extent of the grasp pressure and the geometry of interaction to the extent of hand passivity. For this purpose, a user study has been conducted for 11 healthy human subjects to characterize the energy absorption capability in their arm and wrist. The above correlation is statistically validated. The identified user-specific grasp-based passivity signature map can be used as a graphical tool to assess the biomechanical capabilities of the upper limb in absorbing interaction energy. In this paper, the proposed grasp-based passivity signature map is utilized in the design of a new stabilizer for haptic systems, that takes into account the variation in energy absorption during haptic task execution. The goal is to optimize the haptic system fidelity while guaranteeing human-robot interaction stability despite the potential existence of delays and a non-passive environment. The controller is termed grasp-based passivity signature map stabilizer. If the user provides minimum to no energy absorption during the interaction, the controller makes the force reflection gate tight to guarantee stability. However, when the user demonstrates high capability in absorbing interaction energy, the controller allows the forces to be reflected. The grasp-based passivity signature map stabilizer is an alternative for both conventional stabilizers of haptic/telerobotic systems and fixed conservative force limits in rehabilitation systems where patient-robot interaction safety is a crucial requirement. This provides the practical motivation for this work. Experimental results are presented.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is worth noting that phase lag (even in the order of 10 ms) can easily make a high-gain rehabilitation robot unstable which can sacrifice safety13,56–59.”
From PHTNet: Characterization and Deep Mining of Involuntary Pathological Hand Tremor using Recurrent Neural Network Models (2020) · cites this paper as [58]
Citations
Cites
Vidyasagar, M., & Johnson, S. H. (1978) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3426360 · Cited by 1,817
Compensatory strategies for reaching in stroke
Cirstea, M. C., & Levin, M. F. (2000) · Brain · doi:10.1093/brain/123.5.940 · Cited by 1,006 · cited 10×
“Consequently, f ∗ p−v(t) and f ∗ p−i(t) result in (a) voluntary, and (b) uncoordinated and involuntary patterns of motion, respectively (Cirstea and Levin (2000); Ellis et al.”
BackgroundResultInfluentialAlbu-Schäffer, A., Ott, C., & Hirzinger, G. (2007) · The International Journal of Robotics Research · doi:10.1177/0278364907073776 · Cited by 815 · cited 2×
“It relaxes the conventional passivity assumption on the behavior of the environment (such as the one made in Albu-Schäffer et al. (2007); Chawda and O’Malley (2015)). The major differences between the proposed GPS-map Stabilizer and conventional state-of-the-art time-domain passivity controllers, designed for haptic s…”
BackgroundMethodTime-domain passivity control of haptic interfaces
Hannaford, B., & Ryu, J.-H. (2002) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.988969 · Cited by 767
Neuroplasticity in the context of motor rehabilitation after stroke
Dimyan, M. A., & Cohen, L. G. (2011) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.200 · Cited by 732 · cited 2×
“(1995), Masia and Squeri (2014), Dyck and Tavakoli (2013) and post-stroke patients McCrea et al.”
BackgroundSpastic movement disorder: impaired reflex function and altered muscle mechanics
Dietz, V., & Sinkjaer, T. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70193-x · Cited by 587 · cited 1×
“hypertonia) and increased involuntary reflex activities (De Vlugt et al., 2010; Dietz and Sinkjaer, 2007; Thibaut et al., 2013).”
Telemanipulation with Time Delays
Niemeyer, G., & Slotine, J.-J. E. (2004) · The International Journal of Robotics Research · doi:10.1177/0278364904045563 · Cited by 539
Methods for haptic feedback in teleoperated robot‐assisted surgery
Okamura, A. M. (2004) · Industrial Robot: An International Journal · doi:10.1108/01439910410566362 · Cited by 493 · cited 1×
“(2007), Simorov et al. (2012), and Hapticsenabled Robotic Rehabilitation systems (HRR) Blank et al.”
BackgroundStability results for nonlinear feedback systems
Hill, D. J., & Moylan, P. J. (1977) · Automatica · doi:10.1016/0005-1098(77)90020-6 · Cited by 475 · cited 1×
“(2013), Hill and Moylan (1977), Khalil and Grizzle (2002).”
BackgroundHuman hand impedance characteristics during maintained posture
Tsuji, T., Morasso, P. G., Goto, K., & Ito, K. (1995) · Biological Cybernetics · doi:10.1007/bf00199890 · Cited by 469 · cited 4×
“List of Acronyms GPS: Grasp-based Passivity Signature, FRG function: Force Reflection Gate function, NP: Neural Plasticity, EOP: Excess of Passivity, SOP: Shortage of Passivity, HRR: Haptics-enabled Robotic Rehabilitation, HTR: Hapticsenabled Telerobotic Rehabilitation, PVT: Programmable Virtual Therapist, ISP: Input…”
MethodInfluential
Research works printed but not linked: 2
- Hommel G, 2009, Deutsches Ärzteblatt International, 106, 335
- Khalil HK, 2002, Nonlinear Systems, 3
Cited by
Haptic Feedback and Force-Based Teleoperation in Surgical Robotics
Patel, R. V., Atashzar, S. F., & Tavakoli, M. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3180052 · Cited by 200
“…the aforementioned assumptions are relaxed, and variable time delays are also considered to propose several new categories of stabilizers that guarantee system stability while reducing deterioration in transparency by decreasing the conservatism of the system [92]–[94], [127], [129], [130], [132].”
BackgroundSelf-citationAkbari, A., Haghverd, F., & Behbahani, S. (2021) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.612331 · Cited by 113
“Analyzing the kinesthetic biomechanical capabilities of the target limb is also necessary for developing safe human-robot interaction (Atashzar et al., 2017).”
BackgroundAtashzar, S. F., Carriere, J., & Tavakoli, M. (2021) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.610529 · Cited by 76
Self-citationAn industrial security system for human-robot coexistence
Long, P., Chevallereau, C., Chablat, D., & Girin, A. (2017) · Industrial Robot the international journal of robotics research and application · doi:10.1108/ir-09-2017-0165 · Cited by 67
Review of Advanced Medical Telerobots
Mehrdad, S., Liu, F., Pham, M. T., Lelevé, A., & Atashzar, S. F. (2020) · Applied Sciences · doi:10.3390/app11010209 · Cited by 67
“Thus with the use of advanced technology, including ultra-fast communication, advanced instrumentation, and algorithmic stabilizers [7,64,82,85,150,166,180,181,184], it can be envisioned that the next generation of telerobotic surgical systems is equipped with means of high-fidelity haptics…”
InfluentialSelf-citation
Metadata
- Authors
- Atashzar, S. F., Shahbazi, M., Tavakoli, M., & Patel, R. V.
- Affiliations
- Western University (CA)
- University of Alberta (CA)
- Corresponding author
- Atashzar, Seyed Farokh
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2017-04-04
- Volume
- 36
- Issue
- 5-7
- Pages
- 778-799
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2604635497
- Cited by
- 41
- References
- 61
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 6 · 2023: 8 · 2022: 3 · 2021: 5 · 2020: 11 · 2019: 3 · 2018: 2 · 2017: 1
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The International Journal of Robotics Research (publishedVersion)
- Funders
- Quanser Inc.
- Natural Sciences and Engineering Research Council (NSERC) of Canada and Canadian Institutes of Health Research (CIHR) under a Collaborative Health Research Projects (CHRP) Grant (316170)
- Canada Foundation for Innovation (28241)
- NSERC Discovery Grant (RGPIN 1345)
- AGE-WELL Network of Centres of Excellence Grant (AW CRP 2015-WP5.3)
- Alberta Innovation and Advanced Education Ministry under Small Equipment (RCP-12-021)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
- Keywords
- human-robot interaction, haptic devices, rehabilitation robotics, energy absorption, upper limb biomechanics, force reflection, interaction stability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.