A grasp-based passivity signature for haptics-enabled human-robot interaction: Application to design of a new safety mechanism for robotic rehabilitation
The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
In this paper, the biomechanical capability of the human upper limb in absorbing physical interaction energy during human-robot interaction is analyzed. The outcome is a graphical map that can quantitatively correlate the extent of the grasp pressure and the geometry of interaction to the extent of hand passivity. For this purpose, a user study has been conducted for 11 healthy human subjects to characterize the energy absorption capability in their arm and wrist. The above correlation is statistically validated. The identified user-specific grasp-based passivity signature map can be used as a graphical tool to assess the biomechanical capabilities of the upper limb in absorbing interaction energy. In this paper, the proposed grasp-based passivity signature map is utilized in the design of a new stabilizer for haptic systems, that takes into account the variation in energy absorption during haptic task execution. The goal is to optimize the haptic system fidelity while guaranteeing human-robot interaction stability despite the potential existence of delays and a non-passive environment. The controller is termed grasp-based passivity signature map stabilizer. If the user provides minimum to no energy absorption during the interaction, the controller makes the force reflection gate tight to guarantee stability. However, when the user demonstrates high capability in absorbing interaction energy, the controller allows the forces to be reflected. The grasp-based passivity signature map stabilizer is an alternative for both conventional stabilizers of haptic/telerobotic systems and fixed conservative force limits in rehabilitation systems where patient-robot interaction safety is a crucial requirement. This provides the practical motivation for this work. Experimental results are presented.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is worth noting that phase lag (even in the order of 10 ms) can easily make a high-gain rehabilitation robot unstable which can sacrifice safety13,56–59.”
From PHTNet: Characterization and Deep Mining of Involuntary Pathological Hand Tremor using Recurrent Neural Network Models (2020) · cites this paper as [58]
Citations
Cites
Vidyasagar, M., & Johnson, S. H. (1978) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3426360 · Cited by 1,817
Compensatory strategies for reaching in stroke
Cirstea, M. C., & Levin, M. F. (2000) · Brain · doi:10.1093/brain/123.5.940 · Cited by 1,006 · cited 10×
“Consequently, f ∗ p−v(t) and f ∗ p−i(t) result in (a) voluntary, and (b) uncoordinated and involuntary patterns of motion, respectively (Cirstea and Levin (2000); Ellis et al.”
BackgroundResultInfluentialAlbu-Schäffer, A., Ott, C., & Hirzinger, G. (2007) · The International Journal of Robotics Research · doi:10.1177/0278364907073776 · Cited by 815 · cited 2×
“It relaxes the conventional passivity assumption on the behavior of the environment (such as the one made in Albu-Schäffer et al. (2007); Chawda and O’Malley (2015)). The major differences between the proposed GPS-map Stabilizer and conventional state-of-the-art time-domain passivity controllers, designed for haptic s…”
BackgroundMethodTime-domain passivity control of haptic interfaces
Hannaford, B., & Ryu, J.-H. (2002) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.988969 · Cited by 767
Neuroplasticity in the context of motor rehabilitation after stroke
Dimyan, M. A., & Cohen, L. G. (2011) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.200 · Cited by 732 · cited 2×
“(1995), Masia and Squeri (2014), Dyck and Tavakoli (2013) and post-stroke patients McCrea et al.”
BackgroundSpastic movement disorder: impaired reflex function and altered muscle mechanics
Dietz, V., & Sinkjaer, T. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70193-x · Cited by 587 · cited 1×
“hypertonia) and increased involuntary reflex activities (De Vlugt et al., 2010; Dietz and Sinkjaer, 2007; Thibaut et al., 2013).”
Telemanipulation with Time Delays
Niemeyer, G., & Slotine, J.-J. E. (2004) · The International Journal of Robotics Research · doi:10.1177/0278364904045563 · Cited by 539
Methods for haptic feedback in teleoperated robot‐assisted surgery
Okamura, A. M. (2004) · Industrial Robot: An International Journal · doi:10.1108/01439910410566362 · Cited by 493 · cited 1×
“(2007), Simorov et al. (2012), and Hapticsenabled Robotic Rehabilitation systems (HRR) Blank et al.”
BackgroundStability results for nonlinear feedback systems
Hill, D. J., & Moylan, P. J. (1977) · Automatica · doi:10.1016/0005-1098(77)90020-6 · Cited by 475 · cited 1×
“(2013), Hill and Moylan (1977), Khalil and Grizzle (2002).”
BackgroundHuman hand impedance characteristics during maintained posture
Tsuji, T., Morasso, P. G., Goto, K., & Ito, K. (1995) · Biological Cybernetics · doi:10.1007/bf00199890 · Cited by 469 · cited 4×
“List of Acronyms GPS: Grasp-based Passivity Signature, FRG function: Force Reflection Gate function, NP: Neural Plasticity, EOP: Excess of Passivity, SOP: Shortage of Passivity, HRR: Haptics-enabled Robotic Rehabilitation, HTR: Hapticsenabled Telerobotic Rehabilitation, PVT: Programmable Virtual Therapist, ISP: Input…”
MethodInfluentialConfidence Interval or P-Value? Part 4 of a Series on Evaluation of Scientific Publications
Prel, J.-B. D., Hommel, G., Röhrig, B., & Blettner, M. (2009) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2009.0335 · Cited by 460
Schwamm, L. H., Holloway, R. G., Amarenco, P., Audebert, H. J., Bakas, T., Chumbler, N. R., Handschu, R., Jauch, E. C., Knight, W. A., Levine, S. R., et al. (2009) · Stroke · doi:10.1161/strokeaha.109.192360 · Cited by 449
Spasticity after stroke: Physiology, assessment and treatment
Thibaut, A., Chatelle, C., Ziegler, E., Bruno, M.-A., Laureys, S., & Gosseries, O. (2013) · Brain Injury · doi:10.3109/02699052.2013.804202 · Cited by 447
Motions or muscles? Some behavioral factors underlying robotic assistance of motor recovery
Hogan, N., Krebs, H. I., Rohrer, B., Palazzolo, J. J., Dipietro, L., Fasoli, S. E., Stein, J., Hughs, R., Frontera, W. R., Lynch, D., et al. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.06.0103 · Cited by 374
Hashtrudi-Zaad, K., & Salcudean, S. E. (2002) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.988981 · Cited by 373
Hashtrudi-Zaad, K., & Salcudean, S. E. (2001) · The International Journal of Robotics Research · doi:10.1177/02783640122067471 · Cited by 365
Rehabilitation with Poststroke Motor Recovery: A Review with a Focus on Neural Plasticity
Takeuchi, N., & Izumi, S.-I. (2013) · Stroke Research and Treatment · doi:10.1155/2013/128641 · Cited by 330
Haptics in minimally invasive surgery – a review
Westebring – van der Putten, E. P., Goossens, R. H. M., Jakimowicz, J. J., & Dankelman, J. (2008) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700701820242 · Cited by 328
NEUROExos: a powered elbow exoskeleton for physical rehabilitation
Vitiello, N., Lenzi, T., Roccella, S., De Rossi, S. M. M., Cattin, E., Giovacchini, F., Vecchi, F., & Carrozza, M. C. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2211492 · Cited by 272 · cited 1×
“In fact, the safety of human-robot interactions in hapticsenabled rehabilitation systems could be a major concern (Aguirre-Ollinger et al., 2012; Morbi et al., 2014; Vitiello et al., 2013; Zhang and Cheah, 2015).”
BackgroundBlank, A. A., French, J. A., Pehlivan, A. U., & O’Malley, M. K. (2014) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-014-0056-z · Cited by 240
High-Fidelity Bilateral Teleoperation Systems and the Effect of Multimodal Haptics
Tavakoli, M., Aziminejad, A., Patel, R. V., & Moallem, M. (2007) · IEEE Transactions on Systems Man and Cybernetics Part B (Cybernetics) · doi:10.1109/tsmcb.2007.903700 · Cited by 165
Self-citationBilateral Teleoperation Over Unreliable Communication Networks
Chopra, N., Berestesky, P., & Spong, M. W. (2008) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2007.903397 · Cited by 152 · cited 1×
“(2013), Hogan et al. (2006). NP involving brain remodeling in synaptic and non-synaptic manners helps patients to regain some of their lost motor functions Dimyan and Cohen (2011), Takeuchi and Izumi (2013).”
BackgroundA Control Strategy for Upper Limb Robotic Rehabilitation With a Dual Robot System
Culmer, P. R., Jackson, A. E., Makower, S., Richardson, R., Cozens, J. A., Levesley, M. C., & Bhakta, B. B. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2030796 · Cited by 149 · cited 5×
“, hypertonia), and increased involuntary reflex activities (De Vlugt et al. (2010); Dietz and Sinkjaer (2007); Thibaut et al. (2013)). The weakness in generating motor commands, will result in reduced ability to move the limbs for performing tasks (e.g., position and/or velocity tracking). Considering (3), this corres…”
BackgroundMethodInfluentialModifiability of abnormal isometric elbow and shoulder joint torque coupling after stroke
Ellis, M. D., Holubar, B. G., Acosta, A. M., Beer, R. F., & Dewald, J. P. A. (2005) · Muscle & Nerve · doi:10.1002/mus.20343 · Cited by 146 · cited 1×
“(2013), Hill and Moylan (1977), Khalil and Grizzle (2002).”
BackgroundKim, H., Miller, L. M., Fedulow, I., Simkins, M., Abrams, G., Byl, N. N., & Rosén, J. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2207462 · Cited by 143
Transparent Time-Delayed Bilateral Teleoperation Using Wave Variables
Aziminejad, A., Tavakoli, M., Patel, R. V., & Moallem, M. (2008) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2007.908222 · Cited by 141 · cited 1×
“In this regard, several techniques have been developed to guarantee the stability of delayed haptic systems (Aziminejad et al., 2008; Chawda and O’Malley, 2015; Chopra et al., 2008; Ryu et al., 2004; Sun et al., 2014).”
MethodSelf-citationThe relation between neuromechanical parameters and Ashworth score in stroke patients
de Vlugt, E., de Groot, J. H., Schenkeveld, K. E., Arendzen, J. H., van der Helm, F. C. T., & Meskers, C. G. M. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-35 · Cited by 139 · cited 2×
“HRR systems have been developed to accelerate Neural Plasticity (NP) in the brain through facilitating therapeutic physical interaction of a patient with actual/virtual objects Krebs and Hogan (2006), Kim et al.”
MethodTherapeutic Robotics: A Technology Push
Krebs, H. I., & Hogan, N. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.880721 · Cited by 138 · cited 26×
“In order to analyze the passivity of the user’s hand and develop the stabilizing controller, a transparent twochannel bilateral architecture was previously proposed by the authors Atashzar et al. (2012b) and used for both HRR and HTR systems Atashzar et al. (2015), Atashzar et al. (2012a), Atashzar et al. (2013), Atas…”
BackgroundInfluentialHaptic interaction in robot‐assisted endoscopic surgery: a sensorized end‐effector
Tavakoli, M., Patel, R. V., & Moallem, M. (2005) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.16 · Cited by 132
Self-citationReview of surgical robotics user interface: what is the best way to control robotic surgery?
Simorov, A., Otte, R. S., Kopietz, C. M., & Oleynikov, D. (2012) · Surgical Endoscopy · doi:10.1007/s00464-012-2182-y · Cited by 131
Application of wave-variable control to bilateral teleoperation systems: A survey
Sun, D. M., Naghdy, F., & Du, H. (2014) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2014.03.002 · Cited by 128
Aguirre-Ollinger, G., Colgate, J. E., Peshkin, M. A., & Goswami, A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2176960 · Cited by 126 · cited 4×
“(2013), Aguirre-Ollinger et al. (2012). Most poststroke rehabilitation robots are designed to generate powerful force fields in order to deliver sufficient energy for the required motor therapy while working in contact with post-stroke patients. Consequently, instability in the robots can cause serious injuries includ…”
BackgroundInfluentialPassivity and Stability of Human–Robot Interaction Control for Upper-Limb Rehabilitation Robots
Zhang, J., & Cheah, C. C. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2392451 · Cited by 119
Stability Guaranteed Control: Time Domain Passivity Approach
Ryu, J.-H., Kwon, D.-S., & Hannaford, B. (2004) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2004.833648 · Cited by 102 · cited 1×
“In this regard, several techniques have been developed to guarantee the stability of delayed haptic systems (Aziminejad et al., 2008; Chawda and O’Malley, 2015; Chopra et al., 2008; Ryu et al., 2004; Sun et al., 2014).”
MethodPosition Synchronization in Bilateral Teleoperation Under Time-Varying Communication Delays
Chawda, V., & OMalley, M. K. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2317946 · Cited by 99
Muscle and reflex changes with varying joint angle in hemiparetic stroke
Mirbagheri, M. M., Alibiglou, L., Thajchayapong, M., & Rymer, W. Z. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-6 · Cited by 92
da Vinci robot-assisted keyhole neurosurgery: a cadaver study on feasibility and safety
Marcus, H. J., Hughes‐Hallett, A., Cundy, T. P., Yang, G., Darzi, A. W., & Nandi, D. (2014) · Neurosurgical Review · doi:10.1007/s10143-014-0602-2 · Cited by 88
Lendvay, T. S., Hannaford, B., & Satava, R. M. (2013) · The Cancer Journal · doi:10.1097/ppo.0b013e31828bf822 · Cited by 70
Atashzar, S. F., Polushin, I. G., & Patel, R. V. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2623336 · Cited by 57 · cited 9×
“An example is the recently-developed Haptics-enabled Telerobotic Rehabilitation (HTR) system, proposed by the authors in Atashzar et al. (2015), Atashzar et al. (2012a), Atashzar et al. (2013), Atashzar et al.”
BackgroundMethodInfluentialSelf-citationLinear spring-damper model of the hypertonic elbow: reliability and validity
McCrea, P. H., Eng, J. J., & Hodgson, A. J. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00169-9 · Cited by 54 · cited 1×
“, 1995) and post-stroke patients (De Vlugt et al., 2010; McCrea et al., 2003; Mirbagheri et al., 2008) In Section 4.”
BackgroundAdaptive Suppression of Severe Pathological Tremor by Torque Estimation Method
Taheri, B., Case, D., & Richer, E. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2317948 · Cited by 53 · cited 2×
“This model includes (but is not limited to) the commonly-used passive linear massspring-damper models introduced in the literature for the dynamical reaction of a healthy human upper-limb Tsuji et al. (1995), Masia and Squeri (2014), Dyck and Tavakoli (2013) and post-stroke patients McCrea et al.”
BackgroundMethodSafety Analysis for a Human-Friendly Manipulator
Haddadin, S., Albu‐Schäffer, A., & Hirzinger, G. (2010) · International Journal of Social Robotics · doi:10.1007/s12369-010-0053-z · Cited by 49 · cited 1×
“If ξ < 0, the system is Output Non-Passive (ONP) and the SOP is ξ Vidyasagar (2002), Jazayeri et al. (2013), Hill and Moylan (1977), Khalil and Grizzle (2002).”
BackgroundNetworked teleoperation with non-passive environment: Application to tele-rehabilitation
Atashzar, S. F., Polushin, I. G., & Patel, R. V. (2012) · 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2012.6386152 · Cited by 49 · cited 2×
“In addition to HRR systems, taking advantage of recent developments in the field of communication and cloud-based computerized systems, there is a tendency towards developing remote cloud-based medical applications and rehabilitation systems Butler et al. (2014),Schwamm et al. (2009), Bae et al.”
Self-citationVoluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression
Herrnstadt, G., & Menon, C. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00029 · Cited by 49
Atashzar, S. F., Shahbazi, M., Samotus, O., Tavakoli, M., Jog, M. S., & Patel, R. V. (2016) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2016.2530632 · Cited by 45
Self-citationNetwork-Based Rehabilitation System for Improved Mobility and Tele-Rehabilitation
Bae, J., Zhang, W., & Tomizuka, M. (2012) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2012.2217965 · Cited by 40
Measuring the dynamic impedance of the human arm without a force sensor
Dyck, M., & Tavakoli, M. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650349 · Cited by 37
Self-citationForbes, J. R., & Damaren, C. J. (2010) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2010.5530792 · Cited by 31 · cited 1×
“• Proposing a new safety mechanism which incorporates the proposed GPS map to perform minimum manipulation of transparency while guaranteeing stability, in the context of Strong Passivity Theorem (SPT) Vidyasagar (2002), Forbes and Damaren (2010).”
MethodStability analysis of teleoperation systems under strictly passive and non-passive operator
Jazayeri, A. R., Dyck, M., & Tavakoli, M. (2013) · World Haptics Conference · doi:10.1109/whc.2013.6548493 · Cited by 26
Self-citationExpanding Tele-rehabilitation of Stroke Through In-home Robot-assisted Therapy
Wu, C. B. D. (2013) · International Journal of Physical Medicine & Rehabilitation · doi:10.4172/2329-9096.1000184 · Cited by 23
A Modular Mechatronic Device for Arm Stiffness Estimation in Human–Robot Interaction
Masia, L., & Squeri, V. (2015) · IEEE/ASME transactions on mechatronics · doi:10.1109/tmech.2014.2361925 · Cited by 21
Stability-Guaranteed Assist-as-Needed Controller for Powered Orthoses
Morbi, A., Ahmadi, M., Chan, A., & Langlois, R. (2014) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2013.2259593 · Cited by 21 · cited 2×
“In fact, the safety of human-robot interactions in hapticsenabled rehabilitation systems could be a major concern (Aguirre-Ollinger et al., 2012; Morbi et al., 2014; Vitiello et al., 2013; Zhang and Cheah, 2015).”
BackgroundControl of Robotic Assistance Using Poststroke Residual Voluntary Effort
Makowski, N. S., Knutson, J. S., Chae, J., & Crago, P. (2015) · IEEE transactions on neural systems and rehabilitation engineering · doi:10.1109/tnsre.2014.2364273 · Cited by 20
Projection-based force reflection algorithms for teleoperated rehabilitation therapy
Atashzar, S. F., Polushin, I. G., & Patel, R. V. (2013) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2013.6696394 · Cited by 20
Self-citationAtashzar, S. F., Shahbazi, M., Tavakoli, M., & Patel, R. V. (2015) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7354025 · Cited by 20
Self-citationEnergetic Passivity of the Human Ankle Joint
Lee, H., & Hogan, N. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2540607 · Cited by 20
Sethi, A., Davis, S. B., McGuirk, T. E., Patterson, T. S., & Richards, L. G. (2012) · Journal of Hand Therapy · doi:10.1016/j.jht.2012.09.001 · Cited by 18
Control of time-delayed telerobotic systems with flexible-link slave manipulators
Atashzar, S. F., Shahbazi, M., Talebi, H. A., & Patel, R. V. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6386170 · Cited by 18 · cited 7×
“NP involving brain remodeling in synaptic and non-synaptic manners helps patients to regain some of their lost motor functions Dimyan and Cohen (2011), Takeuchi and Izumi (2013). The effectiveness of HRR systems in accelerating NP have been investigated in several studies Krebs and Hogan (2006), Kim et al. (2013), Hog…”
BackgroundMethodInfluentialSelf-citationInvoluntary movement during haptics-enabled robotic rehabilitation: Analysis and control design
Atashzar, S. F., Saxena, A., Shahbazi, M., & Patel, R. V. (2014) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2014.6943060 · Cited by 7
Self-citationMerians, A. S., & Fluet, G. G. (2014) · Virtual reality technologies for health and clinical applications · doi:10.1007/978-1-4939-0968-1_7 · Cited by 5
(2002) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898719185.bm · Cited by 1
Research works printed but not linked: 2
- Hommel G, 2009, Deutsches Ärzteblatt International, 106, 335
- Khalil HK, 2002, Nonlinear Systems, 3
Cited by
Haptic Feedback and Force-Based Teleoperation in Surgical Robotics
Patel, R. V., Atashzar, S. F., & Tavakoli, M. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3180052 · Cited by 200
“…the aforementioned assumptions are relaxed, and variable time delays are also considered to propose several new categories of stabilizers that guarantee system stability while reducing deterioration in transparency by decreasing the conservatism of the system [92]–[94], [127], [129], [130], [132].”
BackgroundSelf-citationAkbari, A., Haghverd, F., & Behbahani, S. (2021) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.612331 · Cited by 113
“Analyzing the kinesthetic biomechanical capabilities of the target limb is also necessary for developing safe human-robot interaction (Atashzar et al., 2017).”
BackgroundAtashzar, S. F., Carriere, J., & Tavakoli, M. (2021) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.610529 · Cited by 76
Self-citationAn industrial security system for human-robot coexistence
Long, P., Chevallereau, C., Chablat, D., & Girin, A. (2017) · Industrial Robot the international journal of robotics research and application · doi:10.1108/ir-09-2017-0165 · Cited by 67
Review of Advanced Medical Telerobots
Mehrdad, S., Liu, F., Pham, M. T., Lelevé, A., & Atashzar, S. F. (2020) · Applied Sciences · doi:10.3390/app11010209 · Cited by 67
“Thus with the use of advanced technology, including ultra-fast communication, advanced instrumentation, and algorithmic stabilizers [7,64,82,85,150,166,180,181,184], it can be envisioned that the next generation of telerobotic surgical systems is equipped with means of high-fidelity haptics…”
InfluentialSelf-citation
Metadata
- Authors
- Atashzar, S. F., Shahbazi, M., Tavakoli, M., & Patel, R. V.
- Affiliations
- Western University (CA)
- University of Alberta (CA)
- Corresponding author
- Atashzar, Seyed Farokh
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2017-04-04
- Volume
- 36
- Issue
- 5-7
- Pages
- 778-799
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2604635497
- Cited by
- 41
- References
- 61
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 6 · 2023: 8 · 2022: 3 · 2021: 5 · 2020: 11 · 2019: 3 · 2018: 2 · 2017: 1
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The International Journal of Robotics Research (publishedVersion)
- Funders
- Quanser Inc.
- Natural Sciences and Engineering Research Council (NSERC) of Canada and Canadian Institutes of Health Research (CIHR) under a Collaborative Health Research Projects (CHRP) Grant (316170)
- Canada Foundation for Innovation (28241)
- NSERC Discovery Grant (RGPIN 1345)
- AGE-WELL Network of Centres of Excellence Grant (AW CRP 2015-WP5.3)
- Alberta Innovation and Advanced Education Ministry under Small Equipment (RCP-12-021)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
- Keywords
- human-robot interaction, haptic devices, rehabilitation robotics, energy absorption, upper limb biomechanics, force reflection, interaction stability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.