Current methods of preventing aseptic loosening and improving osseointegration of titanium implants in cementless total hip arthroplasty: a review
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Hip osteoarthritis is the most common joint disorder, and is represented by a degenerative process, resulting in pain and functional impairment. If conservative treatment for hip osteoarthritis fails, the only remaining option is hip arthroplasty. Despite good survival of implants, loosening of components is the most common complication. This leads to revision surgeries, which are technically demanding, expensive, and result in a low satisfaction rate. Uncemented hip replacements require proper osseointegration for increased survival. Physical characteristics of implants include biocompatibility, Young’s modulus of elasticity, strength, and corrosion resistance, and each influence fixation of implants. Moreover, implant surface treatments, pore size, pore density, and femoral stem design should be appropriately selected. Patients’ optimization of obesity, osteoporosis, cardiovascular disease, psychotic disorders, and smoking cessation are associated with a higher survival of implants. Surgical factors, such as approach, drilling and rasping, acetabular bone coverage, acetabular cup positioning, and implant size, also affect survival of implants. Avoiding drugs, which may impair osseointegration of implants, and having an appropriate rehabilitation protocol are important. Future directions include anabolic and anti-catabolic bone-acting drugs to enhance osseointegration of implants. Comprehensive knowledge of the factors mentioned above is important for preventing aseptic loosening, with important socioeconomic consequences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
The Glossary of Prosthodontic Terms
(2005) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2005.03.013 · Cited by 1,323
Møller, A. M., Villebro, N., Pedersen, T., & Tønnesen, H. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07369-5 · Cited by 1,126
Biomedical applications of titanium and its alloys
Elias, C. N., Lima, J. H. C., Valiev, R., & Meyers, M. A. (2008) · JOM · doi:10.1007/s11837-008-0031-1 · Cited by 983 · cited 2×
“Toxic-free element alloys, such as Ti-13Nb-13Zr, Ti-12Mo6Zr, and Ti-12Mo-6Zr-2Fe, could be preferred in future medical use.(17,26) The alloys mentioned above are still under development for orthopaedic use.”
Taniguchi, N., Fujibayashi, S., Takemoto, M., Sasaki, K., Otsuki, B., Nakamura, T., Matsushita, T., Kokubo, T., & Matsuda, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.10.069 · Cited by 960
Biocompatibility of Advanced Manufactured Titanium Implants—A Review
Sidambe, A. (2014) · Materials · doi:10.3390/ma7128168 · Cited by 741 · cited 1×
“The most important property of titanium regarding osseointegration is due to a low electrical conductivity, which leads to formation of an oxide layer.(19) This facilitates adhesion of osteoblasts to the surface of titanium and produces better implant fixation compared with other metals.”
Biology of implant osseointegration.
Mavrogenis, A., Dimitriou, R. I., Parvizi, J., & Babis, G. C. (2009) · PubMed · Cited by 639
Surface Modifications and Their Effects on Titanium Dental Implants
Jemat, A., Ghazali, M. J., Razali, M., & Otsuka, Y. (2015) · BioMed Research International · doi:10.1155/2015/791725 · Cited by 611 · cited 7×
“A review by Mavrogenis et al.31 showed that enoxaparin, warfarin, dalteparin, and unfractionated heparin are factors that may inhibit titanium osseointegration, by supressing osteoblast activity in cell cultures.6 However, fondaparinux does not show a negative effect on implant fixation.31 Moreover, previous studies h…”
InfluentialHailer, N. P., Garellick, G., & Kärrholm, J. (2010) · Acta Orthopaedica · doi:10.3109/17453671003685400 · Cited by 458 · cited 1×
“Although survival rates of cementless titanium implants at 10 years are satisfactory (85%), this rate decreases to 70% at 15 years.(9) The most common cause for failure of implants is impaired implant fixation (76%), called aseptic loosening.”
Vanhegan, I. S., Malik, A. K., Jayakumar, P., Islam, S. U., & Haddad, F. S. (2012) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.94b5.27073 · Cited by 362
Metadata
- Authors
- Apostu, D., Lucaciu, O., Berce, C., Lucaciu, D., & Cosma, D.
- Venue
- Journal of International Medical Research
- Publisher
- SAGE Publications
- Published
- 2017-11-03
- Volume
- 46
- Issue
- 6
- Pages
- 2104-2119
- ISSN
- 0300-0605 (ISSN-L)
- 1473-2300
- OpenAlex
- W2765492391
- Cited by
- 236
- References
- 48
- FWCI
- 11.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current methods of preventing aseptic loosening and improving osseointegration of titanium implants in cementless total hip arthroplasty: a review. https://app.cochat.ai/papers/10.1177/0300060517732697
- The paper
- Apostu, D., Lucaciu, O., Berce, C., Lucaciu, D., & Cosma, D. (2018). Current methods of preventing aseptic loosening and improving osseointegration of titanium implants in cementless total hip arthroplasty: a review. Journal of International Medical Research. https://doi.org/10.1177/0300060517732697
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.