Use of Intravenous Tranexamic Acid to Reduce Allogeneic Blood Transfusion in Total Hip and Knee Arthroplasty: A Meta-analysis
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Total hip or knee arthroplasty is associated with significant blood loss. Techniques such as the use of antifibrinolytics or desmopressin, or normovolaemic haemodilution have been used to reduce the need for allogeneic blood transfusion. Tranexamic acid has been used to reduce blood loss and transfusion requirement for total hip and knee arthroplasty, with variable results. This meta-analysis aims to evaluate whether intravenous tranexamic acid, when compared with placebo, reduces blood loss and transfusion requirement in total hip and knee joint replacement surgery and whether it might increase the risk of thromboembolic complications. The literature search was based on MEDLINE, EMBASE, Cochrane Controlled Trials Register, and information from the pharmaceutical company that produces tranexamic acid (Pharmacia-Upjohn). We identified 15 clinical trials and 12 were considered suitable for detailed data extraction. Tranexamic acid reduces the proportion of patients requiring allogeneic blood transfusion (OR 0.16, 95% CI: 0.09–0.26), total amount of blood loss (WMD 460 ml, 95% CI: 274–626 ml), and the total number of units of allogeneic blood transfused (WMD 0.85 unit, 95% CI: 0.36–1.33). Tranexamic acid does not increase the risk of thromboemobolic complications such as deep vein thrombosis, pulmonary embolism, thrombotic cerebral vascular accident, or myocardial infarction (OR 0.98, 95% CI: 0.45–2.12). Intravenous tranexamic acid appears effective and safe in reducing allogeneic blood transfusion and blood loss in total hip and knee arthroplasty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta‐Analysis Of Controlled Clinical Trials
Whitehead, A. (2002) · doi:10.1002/0470854200 · Cited by 827
Investigating and Dealing with Publication and Other Biases
Sterne, J. A. C., Egger, M., & Smith, G. D. (2001) · Systematic Reviews in Health Care · doi:10.1002/9780470693926.ch11 · Cited by 449
Cited by
Effect of tranexamic acid on surgical bleeding: systematic review and cumulative meta-analysis
Ker, K., Edwards, P., Perel, P., Shakur, H., & Roberts, I. (2012) · BMJ · doi:10.1136/bmj.e3054 · Cited by 997
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Wong, J., Abrishami, A., El Beheiry, H., Mahomed, N. N., Roderick Davey, J., Gandhi, R., Syed, K. A., Muhammad Ovais Hasan, S., De Silva, Y., & Chung, F. (2010) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.i.01518 · Cited by 491
Systematic review and meta-analysis of the use of tranexamic acid in total hip replacement
Sukeik, M., Alshryda, S., Haddad, F. S., & Mason, J. M. (2011) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.93b1.24984 · Cited by 428
Yang, Z.-G., Chen, W.-P., & Wu, L.-D. (2012) · The Journal of Bone & Joint Surgery · doi:10.2106/jbjs.k.00873 · Cited by 416
Metadata
- Authors
- Ho, K. M., & Ismail, H.
- Venue
- Anaesthesia and Intensive Care
- Publisher
- SAGE Publications
- Published
- 2003-10
- Volume
- 31
- Issue
- 5
- Pages
- 529-537
- ISSN
- 0310-057X (ISSN-L)
- 1448-0271
- OpenAlex
- W63395447
- Cited by
- 231
- References
- 2
- FWCI
- 0.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.