The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Factors affecting the region of most isometric femoral attachments: Part II: The anterior cruciate ligament
Abstract
During flexion of the intact knee, we measured the changes in distance between possible tibial and femoral attachments of an intraarticular ACL substitute. The change in distance during motion was described by the difference between the longest and shortest distances measured. Using knees from eight cadaver donors, we studied the effects of varying tibial and femoral attach ment locations, applying anterior and posterior forces, and altering the range of flexion. We found that altering the femoral attachment had a much larger effect than had altering the tibial attach ment. No femoral attachments were completely iso metric. Femoral attachments that produced the small est change in tibiofemoral distance, 2 mm and less, formed a band whose greatest width ranged from 3 to 5 mm. The axis of the 2 mm region was nearly proximal- distal in orientation and located near the center of the ACL's femoral insertion. Attachments located anterior to the axis moved away from the tibial attachment with flexion, whereas attachments located posterior to the axis moved toward the tibia. The AP position of the tibial attachment affected the orientation of the 2 mm region. Moving the tibial attach ment posteriorly caused the proximal part of the region to move anterior, with little change in the location of the distal part of the region. Changing the applied joint force from anterior to posterior was similar to moving the tibial attachment posteriorly, but the effect was less pronounced. Increasing the range of flexion from 90° to 120° caused the 2 mm region to become narrower and changed its orientation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Prime Static Stabilizer of the Medial Side of the Knee
WARREN, L. F., MARSHALL, J. L., & GIRGIS, F. (1974) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197456040-00002 · Cited by 278
Cited by
Musahl, V., Plakseychuk, A., Vanscyoc, A., Sasaki, T., Debski, R. E., Mcmahon, P. J., & Fu, F. H. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504271747 · Cited by 331
Li, G., DeFrate, L. E., Sun, H., & Gill, T. J. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503262175 · Cited by 182
Amis, A. A. (2012) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-011-1864-7 · Cited by 143
Zavras, T. D., Race, A., & Amis, A. A. (2005) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-004-0541-5 · Cited by 110
Jagodzinski, M., Foerstemann, T., Mall, G., Krettek, C., Bosch, U., & Paessler, H. H. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.03.021 · Cited by 79
Metadata
- Authors
- Hefzy, M. S., Grood, E. S., & Noyes, F. R.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 1989-03
- Volume
- 17
- Issue
- 2
- Pages
- 208-216
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2107954522
- Cited by
- 450
- References
- 1
- FWCI
- 17.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Factors affecting the region of most isometric femoral attachments: Part II: The anterior cruciate ligament. https://app.cochat.ai/papers/10.1177/036354658901700210
- The paper
- Hefzy, M. S., Grood, E. S., & Noyes, F. R. (1989). Factors affecting the region of most isometric femoral attachments: Part II: The anterior cruciate ligament. The American Journal of Sports Medicine. https://doi.org/10.1177/036354658901700210
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.