The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Radiographic Measures of Knee Alignment in Patients with varus Gonarthrosis: Effect of Weightbearing Status and Associations with Dynamic Joint Load
Abstract
Background: Radiographic measures of lower limb malalignment are used to indicate abnormal loading of the knee and to plan corrective procedures. Hypotheses: Weightbearing status during hip-to-ankle radiographs will significantly affect malalignment measures; malalignment in single-limb standing will be most highly correlated to the external knee adduction moment during gait, a proposed dynamic measure of functional knee joint load. Study Design: Controlled laboratory study. Methods: Mechanical axis angle was measured in 40 patients with varus gonarthrosis from hip-to-ankle radiographs taken with patients in single-limb standing, double-limb standing, and supine positions. Kinematic and kinetic data were collected during walking and used to calculate the peak adduction moment about the knee. Results: Repeated-measures analysis of variance and Scheffé post hoc tests indicated that mechanical axis angle measured on single-limb standing radiographs (-8.7°± 4.0°) was significantly greater than on double-limb standing radiographs (-7.1°± 3.8°), which was significantly greater than on supine radiographs (-5.5°± 2.8°). The peak knee adduction moment (2.8 ± 0.8 percentage body weight × height) was only moderately correlated with mechanical axis angle on single-limb standing (r = -0.46), double-limb standing (r = -0.45), and supine (r = -0.43) radiographs. Conclusion: Patient position significantly affects frontal plane knee alignment. However, the peak knee adduction moment is only moderately correlated to mechanical axis angle, regardless of weightbearing status. Clinical Relevance: These findings are inconsistent with the hypothesis that mechanical axis angle measured in single-limb standing is more representative of dynamic joint load and further highlight the differences between static and dynamic measures. Results also underscore the importance of reporting patient position during radiographs and keeping positions consistent when evaluating patients over time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Cited by
Loading of the Knee Joint during Activities of Daily Living Measured In Vivo in Five Subjects
Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.046 · Cited by 798
Foroughi, N., Smith, R., & Vanwanseele, B. (2009) · The Knee · doi:10.1016/j.knee.2008.12.007 · Cited by 270
Metadata
- Authors
- Specogna, A. V., Birmingham, T. B., Hunt, M. A., Jones, I. C., Jenkyn, T. R., Fowler, P. J., & Giffin, J. R.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2007-01
- Volume
- 35
- Issue
- 1
- Pages
- 65-70
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2002035751
- Cited by
- 167
- References
- 1
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiographic Measures of Knee Alignment in Patients with varus Gonarthrosis: Effect of Weightbearing Status and Associations with Dynamic Joint Load. https://app.cochat.ai/papers/10.1177/0363546506293024
- The paper
- Specogna, A. V., Birmingham, T. B., Hunt, M. A., Jones, I. C., Jenkyn, T. R., Fowler, P. J., & Giffin, J. R. (2007). Radiographic Measures of Knee Alignment in Patients with varus Gonarthrosis: Effect of Weightbearing Status and Associations with Dynamic Joint Load. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546506293024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.